The fan speed is selected by pressing the FAN button. This button

is used to set the fan speed in the following sequence:

Fan Speeds: Low

Medium

High

NOTE:

When the unit is on, the fan will run continuously in

cooling or heating. When in heating, there might be situations
where the fan will slow down or shut off to prevent cold blow.

TURBO MODE

The desired setpoint, either in heating or cooling, can be achieved

faster if TURBO mode is used. After selecting the “HEAT” or
“COOL” mode button, push the “TURBO” button. This will force

the unit to run at super high speed. When the setpoint is satisfied,

push the “TURBO” button again. The unit will run at the selected
fan speed.
When TURBO mode is running, the following is displayed on the
remote control:

OPER

º

F

º

C

HOUR
ON/OFF

   

:

Turbo

Icon

A09636

Displaying Setpoint or Room Temperatures on Front Panel

The setpoint temperature or room temperature can be displayed on

the front panel. Only setpoint temperature is displayed on the
remote.

º

F

º

C

HOUR
ON/OFF

   

:

Room

Temperature

Icon

A09638

When the “TEMP” button is pushed once, the temperature

indicator (without thermometer) is displayed. This indicates that
the setpoint temperature is displayed on the front panel.
When the “TEMP” button is pushed a second time, a thermometer
is displayed inside the temperature indicator. This indicates that

the room temperature is displayed on the front panel.

NOTE: If any other button is pushed on remote control, the
temperature will return to the set point temperature. Outdoor
air temperature is not available.

Using Dry Coil Function (X--Fan):

When operating in humid areas, hi--wall units have a DRY COIL

function that will allow the indoor fan to run for a pre--determined
amount of time (10 minutes) after the unit is turned off

(cooling

or dry modes)

to ensure that additional moisture is removed from

coil. Push the “X--FAN” button to enable this feature. This will

be displayed on remote control.

OPER

º

F

º

C

HOUR
ON/OFF

   

:

Remote

Dry Coil

Icon

A09637

To deactivate this feature, push the “X--FAN” button again.

Selecting the Horizontal Direction Louver Position

When the unit is turned on, the louvers default to the cooling or

heating position.
If the louver position is not providing adequate comfort due to

room layout or where people are gathered, two options are
available to correct the situation:

Setting the louvers in a stationary position

(other than default for heating and cooling):

The stationary position can be one of five (5) default positions.
To change the louver position, press the

“SWING“ button

once. The

icon is displayed on the remote.

OPER

ºF

ºC

HOUR
ON/OFF

   

:

Swing Icon

A09640

When the

is displayed, the louver will swing continuously

between positions 1 and 5 as shown below.

OFF

0

1

2

3

4

5

6

7

8

A09634

If the “SWING”

button is pushed again,the louver will

move to position 1. If position 2 through 5 is desired, push the

button repeatedly until the desired position (2 through 5)

is displayed on remote control.

Setting the louvers to move continuously:

This setting allows the louvers to move continuously between
either positions 1 through 5, or between positions 6, 7, and 8.

Push the

button once to have louvers swinging between

positions 1 and 5. If position 6, 7, or 8 is desired, push the

button repeatedly until the desired position is displayed on the

remote.

NOTE: Always use the remote control to adjust the horizontal
louver position otherwise, abnormal operation may occur. If
this occurs, turn the unit off and then on again.
Sometimes, in the heating mode, when the

”SWING”

button is pushed, the louvers will not start moving right away.
This is due to the fact that the fan will not start running until
the coil temperature is warm enough to prevent discomfort to
the user by blowing cold air.

Содержание 40GVM

Страница 1: ...convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful sho...

Страница 2: ...wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the r...

Страница 3: ...ontrol holder 7 1 2 3 5 6 8 9 10 4 7 Front Panel Frame Display Panel shown for 40GXM units Front Panel Air Filter Horizontal Airflow Louver Manual Adjustable Vertical Airflow Louver Remote Control Roo...

Страница 4: ...and Down Buttons 5 Fan Speed 6 Horizontal Louver Swing Button 7 Clock Button 8 Timer ON Button 9 Dry Coil Button 10 Temperature Button 11 Timer OFF Button 12 Turbo Mode Button 13 Sleep Mode button 14...

Страница 5: ...ing in AUTO mode 4 MODE DISPLAY Indicates the current operation mode AUTO COOL DRY FAN ONLY or HEAT 5 SLEEP DISPLAY Indicates unit is running in SLEEP mode 6 TEMPERATURE DISPLAY Temperature setting fr...

Страница 6: ...ress the button the time moves forward or backward by one minute de pending on which button you press If you push the or button continuously the time adjusts in increments of 10 minutes 3 When the rig...

Страница 7: ...nel will turn red and the remote control will display the setpoint and time OPER will disappear NOTE If the On Off button is pressed too soon after a stop the compressor will not start for 3 minutes d...

Страница 8: ...ry modes to ensure that additional moisture is removed from coil Push the X FAN button to enable this feature This will be displayed on remote control OPER F C HOUR ON OFF Remote Dry Coil Icon A09637...

Страница 9: ...ll continue operating normally NOTE When the unit is shut off by the user using the ON OFF button and if the TIMER ON is set the following will be displayed on the remote control Set Point Time Clock...

Страница 10: ...ng Features If the unit is in the heating mode there will be a delay when the fan starts The fan will start only after the coil is warmed up to prevent cold blow Defrost Operation In heating mode if t...

Страница 11: ...ay result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they m...

Страница 12: ...call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller will delay the unit for 3 minutes before allowing the unit to start...

Отзывы: