CableWorld CW-4988 Скачать руководство пользователя страница 2

CW-4887,-88, CW-4987,-88

MPEG-2 Encoder

In the first tests simple switches can be used, 

but   we   suggest   using   switches   suitable   for 
managing IGMP messages as soon as possible.

The  factory  setting for the MPEG-2 Encoder  is 

IP   address   10.123.13.101.   When   using   several 
devices,   set   different   IP   addresses   with   the   SW-
4901 software to avoid IP address conflict. Users 
find   help   in   descriptions   CW-Net.pdf   and 
Using_CW-Net.pdf, which can be downloaded from 
the ‘Papers’ page of the web site.

Probably, transmitting the transport stream over 

IP  network  holds  surprises  even for users having 
good   networking   knowledge.   The   most   important 
knowledge   is   summarised   in   the   publication 
‘Transport Stream Managing over IP’ (TSMoIP.pdf).

Important  note:   The   gigabit   system   of 

CableWorld is a very advanced, high performance 
system, where the transport streams and the device 
control   commands   are   transmitted   in   a   common 
network; decreasing your expenses and increasing 
the   potential   of   remote   control.   The   transport 
streams  and   the   control   commands   are   selected 
according to the Port numbers. The user’s job is, 
assigning   the   Port   number   range   to   be   used   for 
transmitting   the   TS   and   programming   it   in   the 
device.   The   device   control   must   be   performed 
outside the TS Port Interval. The device control can 
be totally disabled by the transport streams outside 
the TS Port Interval.

In   the  CableWorld’s  system   the   gigabit 

transmission is performed by FPGA circuitry, so the 
data rate is not limited by the performance of the 
internal processors, and the gigabit data rate can 
be utilized up to 100%.

4. PUTTING THE DEVICES IN OPERATION

After unpacking remove the protection foil from 

the stainless steel cover of the device. Connect the 
device to the specified mains voltage and switch on 
the power switch. Within a few seconds the device 
is ready to operation.

Programming the device and saving the settings 

is   required   only   when   putting   the   device   in 
operation first or when modifying the settings.

5. TECHNICAL DATA

The technical data of the devices are published 

in their data sheets, which are available at the web 
site www.cableworld.hu.

Additional technical data:

All   ASI   inputs   and   outputs   are   insulated   by 

transformers, which assure 2000 V separation. This 
design is very advantageous in applications, where 
arising of earth currents due to transmission of the 
ASI signal between different rooms or laboratories 
have to be prevented.

From   the   point   of   view   of   electromagnetic 

radiations and protection against disturbances, it is 
advantageous   if   the   outer   shielding   of   the   ASI 
connecting cable is earthed at a proper point. This 
point   has   to   be   found   individually   in   each 
application.

In  the  CW-4000 system of CableWorld the ASI 

inputs have metallic BNC connectors, the shielding 
of   the   coaxial   cable   is   earthed   here.   The   output 
connectors are insulated.

6. SUPPLEMENT

We appreciate if the users are going to integrate 

our products into their system and undertake writing 
own   software   for   operating   these   products. 
CableWorld assure extra technical support for the 
creative   users;   in   the   CableWorld’s   system   the 
instruction sets are free available for everyone, and 
major   users   can   have   the   source   codes   of   the 
software, too. 

Beyond  serial products, CableWorld is ready to 

deliver   products   for   special   demands   and 
implement individual ideas.

We   appreciate   receiving   all   remarks, 

experiences,   measuring   results   with   our   products 
and   we   pay   respect   to   them   at   our   further 
developments. 

Our address: 

[email protected]

.

Отзывы: