Cabletron Systems SWPIM-SY Скачать руководство пользователя страница 46

Appendix B: Cables and Pinouts

B-16

SWPIM-SY Installation Guide

B.10 RS232 / DCE CABLE

Cable Part Number:   9380415 

Note:  * For Cable ID attach CID0    pin #19 to pin #2

Table B-11

RS232 / DCE Cable 

Connector # 1
(36 Pin Male Conn. w/Back 
Shell)

RS232 / DCE

P
A
I
R

Connector # 2
(DB 25  Pin Female Conn. w/Back 
Shell)

RS232 / DTE

Dir
To

 Signal Name

Pin #

Pin #

Signal Name

Mne-
monic

DCE

TXD Transmit Data

 10

  2

TXD Transmit Data

BA

DTE

RXD Receive Data

  5

  3

RXD Receive Data

BB

DTE

CTS Clear to Send

  8

  5

CTS Clear to Send

CB

DCE

RTS Req. to Send

  9

  4

RTS Req. to Send

CA

DTE

DCD Carrier Detect

  6

  8

DCD Carrier Detect

DTE

TXC Transmit Timing

 17

15

TXC Transmit Timing

DB

DTE

RXC Receive Timing

 15

17

RXC Receive Timing

DD

DCE

SCTE   Transmit Timing

 13

24

SCTE   Transmit Timing

DA

DTE

RI  Ring Indicator

 18

22

RI  Ring Indicator

CE

DCE

RL  Remote Loopback

 29

21

RL  Remote Loopback

RL

DCE

LL  Local Loopback

 11

18

LL  Local Loopback

LL

DTE

TM  Test Mode

 36

25

TM  Test Mode

TM

DTE

DSR  DCE Ready

 14

  6

DSR  DCE Ready

CC

DCE

DTR  DTE Ready

  4

20

DTR  DTE Ready

CD

DTE

CID0  Cable ID

*19/21

Signal Common

16

  7

Signal Common

AB

Shield DRAIN

  1

Содержание SWPIM-SY

Страница 1: ...SWPIM SY LNK Title Page SWPIM SY Installation Guide 9033001 02...

Страница 2: ......

Страница 3: ...ioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two co...

Страница 4: ...ervice in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment...

Страница 5: ...y the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitte...

Страница 6: ...computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all resp...

Страница 7: ...he right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program...

Страница 8: ...computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all resp...

Страница 9: ...ICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any pa...

Страница 10: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all res...

Страница 11: ...5022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that th...

Страница 12: ...Notice x SWPIM SY Installation Guide...

Страница 13: ...Installation 1 5 APPENDIX A SPECIFICATIONS A 1 Physical Properties A 1 A 2 Network Interface A 1 A 3 Environmental Requirements A 3 A 4 Regulatory Compliance A 3 APPENDIX B CABLES AND PINOUTS B 1 Int...

Страница 14: ...Contents xii SWPIM SY Installation Guide...

Страница 15: ...rking knowledge of WAN and Ethernet and IEEE 802 3 data communications networks and their physical layer components is helpful before using the SWPIM SY STRUCTURE OF THIS GUIDE This guide is organized...

Страница 16: ...e SWPIM SY uses a 36 pin AMP female connector supporting the following electrical signal interfaces EIA 232 D EIA 449 V 35 X 21 EIA 530 EIA 530A Refer to Appendix B for the Cabletron Systems part numb...

Страница 17: ...Wide Web in Adobe Acrobat Portable Document Format PDF at the following site http www cabletron com Cabletron Systems applicable software manuals for the SSR 600 and the HSIM SSR 600 host platforms C...

Страница 18: ...ttention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avo...

Страница 19: ...tems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the de...

Страница 20: ...Introduction xviii SWPIM SY Installation Guide...

Страница 21: ...M SY 2 Attach the antistatic strap refer to the instructions in the antistatic wrist strap package before removing the SWPIM SY from the antistatic packaging 3 Verify that the SWPIM SY is undamaged Re...

Страница 22: ...nded 4 Remove the SWPIM SY from the plastic bag Save the bag in the event the device must be removed from the host platform 5 Hold the SWPIM SY with the faceplate facing away right side up from the ho...

Страница 23: ...M SY must be configured before the WAN connection is made Once the SWPIM SY has been configured the host platform must undergo a soft or hard restart in order for the SWPIM SY to be recognized and for...

Страница 24: ...NNECTING TO THE NETWORK Figure 1 2 depicts a common configuration for the SWPIM SY It is shown only as an example of a setup used for the SWPIM SY Figure 1 2 Common Configuration for the SWPIM SY Tabl...

Страница 25: ...and the other uses a push release mechanism whereby the connector is removed by squeezing the release buttons Figure 1 3 V 35 Cable 1 5 COMPLETING THE INSTALLATION After installing the SWPIM SY the S...

Страница 26: ...Chapter 1 Installation 1 6 SWPIM SY Installation Guide...

Страница 27: ...network port that supports the electrical signal interfaces in Table A 1 Table A 1 also shows the minimum and maximum speeds of the Synchronous Asynchronous module Dimensions 1 98 H x 5 40 W x 19 35 D...

Страница 28: ...DCE High or DTE Low RL Remote Loopback TM Test Mode Signal Dir To Pin Signal Dir To Pin GND 1 CID0 19 CID1_ 2 CID2_ 20 DCEDTE_ 3 GND 21 DSR_A DTE 4 DSR_B DTE 22 TXD_A DCE 5 TXD_B DCE 23 DCD_A DTE 6 D...

Страница 29: ...thout D3 deviations CSA C22 2 No 950 and EN 60950 EMI FCC Part 15 Class A EN 55022 Class A and VCCI Class I Electromagnetic Compatibility EMC EN 50082 1 including IEC 801 2 ESD IEC 801 3 Radiated Susc...

Страница 30: ...Appendix A Specifications A 4 SWPIM SY Installation Guide...

Страница 31: ...MBERS Table B 1 lists the DTE interface cable part numbers and table numbers for the SWPIM SY The standard length for all cables is 10 feet Table B 1 DTE Interface Cable Types and Cabletron Part Numbe...

Страница 32: ...le B 13 EIA 530A 500 9380421 Table B 14 NOTE For all the following tables Dir To indicates the direction of the signal Notes at the bottom of all the tables in this Appendix are supplied as reference...

Страница 33: ...g RT DTE RXC B Receive Timing 31 26 RXC B Receive Timing RT DCE DTR A Terminal Ready 14 H 12 DTR A Terminal Ready TR DCE DTR B Terminal Ready 32 30 DTR B Terminal Ready TR DCE SCTE A Transmit Timing 1...

Страница 34: ...9 D CTS Clear to Send 106 DCE RTS Req to Send 8 C RTS Req to Send 105 DTE DCD Carrier Detect 6 F DCD Carrier Detect DTE TXC A Transmit Timing 17 C Y TXC A Transmit Timing 114 DTE TXC B Transmit Timin...

Страница 35: ...n 21 DTE CID0 Cable ID 19 21 DTE CID1 Cable ID 2 21 DTE DCEDTE_ 3 7 Signal Ground 25 A Signal Ground Signal common 16 B Signal Common 102 Shield DRAIN 1 Table B 4 CCITT V 35 DTE Cable Continued Connec...

Страница 36: ...ve Data BB DTE CTS Clear to Send 9 5 CTS Clear to Send CB DCE RTS Req to Send 8 4 RTS Req to Send CA DTE DCD Carrier Detect 6 8 DCD Carrier Detect DTE TXC Transmit Timing 17 15 TXC Transmit Timing DB...

Страница 37: ...XD A Transmit Data 5 A 2 TXD A Transmit Data T DCE TXD B Transmit Data 23 9 TXD B Transmit Data T DTE RXD A Receive Data 10 B 4 RXD A Receive Data R DTE RXD B Receive Data 28 11 RXD B Receive Data R D...

Страница 38: ...lear to send CB DTE CTS B Clear to send 27 13 CTS B Clear to send CB DCE RTS A Req to Send 8 D 4 RTS A Req to Send CA DCE RTS B Req to Send 26 D 19 RTS B Req to Send CA DTE DCD A Carrier Detect 6 E 8...

Страница 39: ...eady CC DCE DTR A DTE Term Ready 14 J 20 DTR A DTE Term Ready CD DCE DTR B DTE Term Ready 32 23 DTR B DTE Term Ready CD DTE CID1 Cable ID 2 21 DTE CID3 Cable ID 30 21 DTE DCEDTE_ 3 7 Signal Ground 25...

Страница 40: ...Clear to send 27 13 CTS B Clear to send CB DCE RTS A Req to Send 8 D 4 RTS A Req to Send CA DCE RTS B Req to Send 26 D 19 RTS B Req to Send CA DTE DCD A Carrier Detect 6 E 8 DCD A Carrier Detect CF D...

Страница 41: ...DTE Term Ready 14 J 20 DTR DTE Term Ready CD DTE CID2 Cable ID 20 21 DTE CID1 Cable ID 2 21 DTE DCEDTE_ 3 7 Signal Ground 25 1 Signal Ground Signal Common 16 7 Signal Common AB Signal Common 34 23 Si...

Страница 42: ...A Receiver Ready RR DTE DCD B Receiver Ready 24 31 DCD B Receiver Ready RR DCE RTS A Req to Send 9 D 7 RTS A Req to Send RS DCE RTS B Req to Send 27 25 RTS B Req to Send RS DTE CTS A Clear to Send 8 E...

Страница 43: ...back 11 10 LL Local Loopback LL DTE TM Test Mode 36 18 TM Test Mode TM DCE RL Remote Loopback 29 14 RL Remote Loopback RL DTE CID1 Cable ID 2 21 Signal Common 16 19 37 Signal Ground Signal common SG S...

Страница 44: ...lear to Send 106 DCE RTS Req to Send 9 C RTS Req to Send 105 DTE DCD Carrier Detect 6 F DCD Carrier Detect DTE TXC A Transmit Timing 17 C Y TXC A Transmit Timing 114 DTE TXC B Transmit Timing 35 AA TX...

Страница 45: ...n 21 DTE CID1 Cable ID 2 21 Signal Ground 25 A Signal Ground Signal common 16 B Signal Common 102 Shield DRAIN 1 Table B 10 CCITT V 35 DCE Cable Continued Connector 1 36 Pin Male Conn w Back Shell CCI...

Страница 46: ...B DTE CTS Clear to Send 8 5 CTS Clear to Send CB DCE RTS Req to Send 9 4 RTS Req to Send CA DTE DCD Carrier Detect 6 8 DCD Carrier Detect DTE TXC Transmit Timing 17 15 TXC Transmit Timing DB DTE RXC R...

Страница 47: ...nsmit Data 10 A 2 TXD A Transmit Data T DCE TXD B Transmit Data 28 9 TXD B Transmit Data T DTE RXD A Receive Data 5 B 4 RXD A Receive Data R DTE RXD B Receive Data 23 11 RXD B Receive Data R DTE CTS A...

Страница 48: ...Clear to send CB DCE RTS A Req to Send 9 D 4 RTS A Req to Send CA DCE RTS B Req to Send 27 D 19 RTS B Req to Send CA DTE DCD A Carrier Detect 6 E 8 DCD A Carrier Detect CF DTE DCD B Carrier Detect 24...

Страница 49: ...CE DTR B DTE Term Ready 22 23 DTR B DTE Term Ready CD DTE CID1 Cable ID 2 21 DTE CID3 Cable ID 30 21 Signal Ground 25 1 Signal Ground Signal Common 16 7 Signal Common AB Signal DRAIN 1 7 Table B 13 EI...

Страница 50: ...ar to send 8 C 5 CTS A Clear to send CB DTE CTS B Clear to send 26 13 CTS B Clear to send CB DCE RTS A Req to Send 9 D 4 RTS A Req to Send CA DCE RTS B Req to Send 27 D 19 RTS B Req to Send CA DTE DCD...

Страница 51: ...DSR DCE Set Ready CC DCE DTR DTE Term Ready 4 J 20 DTR DTE Term Ready CD DTE CID2 Cable ID 20 21 DTE CID1 Cable ID 2 21 Signal Ground 25 1 Signal Ground Signal Common 16 7 Signal Common AB Signal Com...

Страница 52: ...Appendix B Cables and Pinouts B 22 SWPIM SY Installation Guide...

Отзывы: