Chapter 3: Installation
3-16
EMM-E6 Installation Guide
Figure 3-8
SMA Connector Insertion
3. Attach the other fiber of the pair to the applicable transmit port on the
module.
4. At the other end of the fiber optic cable, attach the fiber pair to the
transmit and receive ports of the device.
If link indicators are present for the fiber optic connection, check that they
are ON. If an indicator is present but not ON, that port does not have a
valid link. Perform each of the following steps until you reach a resolution
of the problem and achieve a link.
•
Check that the device at the other end of the link is ON.
•
Verify proper crossover of the fiber strands. Try swapping the transmit
and receive connections at only one end of the link.
•
Verify that the fiber connection meets the dB loss specifications
outlined in Appendix C, Ethernet Cabling Requirements.
If you are still unable to establish a link, attempt to make the connection
between the devices with another fiber optic cable. If this is unsuccessful,
contact Cabletron Systems Technical Support.