Chapter 3: Installation
3-10
8H02-16 User’s Guide
3. Verify that a Link exists by checking that the port RX LED is on
(flashing green or yellow or on solid green). If the RX LED is off,
perform the following steps until it is on:
a.
Check that the 100BASE-TX device at the other end of the twisted
pair segment is powered up.
b. Verify that the RJ45 connector on the twisted pair segment has the
proper pinouts.
c.
Check the cable for continuity.
d. Make sure that the twisted pair connection meets dB loss and cable
specifications outlined in Section 2.1.2.
e.
Confirm that the crossover switch is in the correct position.
If a Link is not established, contact Cabletron Systems Technical Support.
Refer to Section 1.7, Getting Help, for details.
3.5.3
Connecting a Multimode Segment to the
FE-100FX
The FE-100FX has an SC style network port (see Figure 3-8). Cabletron
Systems supplies fiber optic cable that uses SC style connectors that are
keyed to ensure proper crossing over of the transmit and receive fibers.
!
CAUTION
An odd number of crossovers (preferably one) must be
maintained between devices so that the transmit port of one
device is connected to the receive port of the other device and
vice versa.
If the fiber optic cable being used has SC style connectors that
do not resemble MIC style connectors, or has SC connectors
on one end and a different type on the other, such as ST
connectors, ensure that the proper crossing over occurs.
Содержание SmartSwitch 8H02-16
Страница 2: ......
Страница 10: ...Contents viii 8H02 16 User s Guide ...
Страница 20: ...Chapter 1 Introduction 1 10 8H02 16 User s Guide ...
Страница 116: ...Appendix A Specifications A 4 8H02 16 User s Guide ...
Страница 132: ......