SmartSwitch ATM Switch 
User Guide

35 Industrial Way
Rochester, NH 03866
USA
(603) 332-9400

Part Number 04-0053-01 Rev. A 
Order Number 9033002

Содержание SmartSwitch 04-0053-01

Страница 1: ...SmartSwitch ATM Switch User Guide 35 Industrial Way Rochester NH 03866 USA 603 332 9400 Part Number 04 0053 01 Rev A Order Number 9033002...

Страница 2: ...ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright 1998 99...

Страница 3: ...appropriate Setup and Installation Guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user...

Страница 4: ...Newbury Berkshire RG13 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EC Directive 73 23 EEC EN 55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipm...

Страница 5: ...otechnical Commission CENELEC EN 60825 European Committee for Electrotechnical Standardization When operating within their performance limitations laser transceiver output meets the Class 1 accessible...

Страница 6: ...mtronics p n ES1270 or equivalent 2 Using a fiber port cleaning swab Alcoa Fujikura LTS p n ACT 01 or equivalent saturated with optical grade isopropyl alcohol gently wipe the end surface of ferrules...

Страница 7: ...SUMMARY SAFETY SmartSwitch ATM switches meet the safety requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EEC EMC SmartSwitch ATM switches meet the EMC requirements of FCC Part 15 E...

Страница 8: ...ISION HISTORY Document Name SmartSwitch ATM Switch User Guide Document Part Number 04 0053 01 Rev A Document Order Number 9033002 Author Bruce Jordan Editor Ayesha Maqsood Illustrator Mike Fornalski D...

Страница 9: ...icies 2 11 2 2 6 LANE Over WAN Circuits 2 14 2 2 7 Using LNNI 2 16 3 PNNI Routing 3 1 3 1 PNNI Node Addressing 3 1 3 1 1 Default PNNI Addressing 3 1 3 2 Multi level PNNI Topology 3 3 3 2 1 Connecting...

Страница 10: ...uffers 6 5 6 1 4 EFCI EPD and RM Cell Marking 6 7 7 Firmware Upgrades and Bootline Commands 7 1 7 1 Update Firmware Commands 7 1 7 2 Bootline Commands 7 2 7 2 1 Accessing the Bootline Prompt 7 3 7 2 2...

Страница 11: ...itNet Proprietary MIBs A 2 A 1 2 Relation Between Object Identifier and the Represented Value A 3 A 1 3 Supported protocols A 4 A 1 4 Supported SMI Formats A 4 A 1 5 CSI ZeitNet Proprietary MIB Groups...

Страница 12: ...xii SmartSwitch ATM User Guide Table of Contents...

Страница 13: ...en groups A and B 3 7 Figure 3 3 Adding a third PNNI node for next level connectivity 3 8 Figure 3 4 Aggregation token values and parallel links 3 11 Figure 4 1 IISP route across PNNI domain 4 3 Figur...

Страница 14: ...xiv SmartSwitch ATM User Guide List of Figures...

Страница 15: ...s LIST OF TABLES Table 2 1 ELAN Join Policies 2 12 Table 6 1 Traffic descriptor type number explanation 6 2 Table 7 1 Bootline commands 7 4 Table 9 1 Settings for Class of Service Queues 9 4 Table A 1...

Страница 16: ...xvi SmartSwitch ATM User Guide List of Tables...

Страница 17: ...sing the SmartSwitch ATM switch features By reading this manual you will learn how to perform the following operations Creating and managing IP over ATM VLANs Creating and managing ELANS Using distrib...

Страница 18: ...that are not supported by the other SmartSwitch ATM switches The following is a list of capabilities supported by the SmartSwitch 6500 only PVPs Soft PVPs all SmartSwitch ATM switches support soft PV...

Страница 19: ...er through the terminal port or through the Ethernet interface by telnet 2 Create a client on the switch and assign it as the ARP server for the VLAN SmartSwitch add ipatmclient ClientNumber 0 1 Serve...

Страница 20: ...r VLAN members 5 Configure the ATM interface or adapter for end nodes and edge devices Typically configuration consists of designating IP over ATM as the connection type assigning the device an IP add...

Страница 21: ...ddress For example if the chassis MAC address 00 20 D4 14 41 80 then Default netprefix 39 00 00 00 00 00 00 00 00 00 14 41 80 Default Netprefix for SmartSwitch 6500 The default netprefix is constructe...

Страница 22: ...ge devices to use ELAN name ELAN000 and then plug them into the ATM SmartSwitch 1 Enter the start lecs command to activate LANE server services on this ATM SmartSwitch SmartSwitch start lecs NOTICE LE...

Страница 23: ...t 1 LANE Client 1 Client State Operational Client Address 39 00 00 00 00 00 00 00 00 00 14 41 80 00 20 D4 14 41 81 00 LAN Name Marketing LECS Addr Source ILMI LECS Address 39 00 00 00 00 00 00 00 00 0...

Страница 24: ...is best and management easiest when the One subnet per ELAN rule is observed 2 2 1 ATM Addressing for LAN Emulation All ATM SmartSwitches provide default formats for ATM addresses used by LAN emulatio...

Страница 25: ...0B CPU MAC address 00 20 D4 14 41 80 ELAN number 3 then default LES and BUS addresses 39 00 00 00 00 00 00 00 00 00 14 41 80 00 20 D4 14 41 83 02 SmartSwitch 6500 Default LANE Addressing The netprefix...

Страница 26: ...00 00 00 00 1D A3 87 0B 05 2 2 2 ELANs Across Multiple Switches ELANs can exist within a single switch or they can span multiple switches When an ELAN spans multiple switches it s important that all...

Страница 27: ...emulation and add ipatmclient for IP over ATM For example the following command adds a switch client to the ELAN elan1 SmartSwitch add laneclient ClientNumber 0 1 LanName ELAN001 elan1 ServerType LECS...

Страница 28: ...ress of LES 02 Max Frame Size 1516 Connection Method SVC Distribute VPI VCI 0 0 Distribute Method PROXY ELAN Type 802 3 Multipoint YES Error Logging NO Min TD Negotiation NO BUS Address 39 00 00 00 00...

Страница 29: ...e switch See Section 2 2 7 Using LNNI for details 2 2 5 ELAN Join Policies ATM SmartSwitches provide control over the assigning of clients to ELANs Control is accomplished by ELAN join policies By def...

Страница 30: ...join policies are create each with the same priority value a client requesting LANE services must meet the criteria of all three policies to be assigned an ELAN If the client fails to meet the require...

Страница 31: ...pecified Subsequently This policy will be tried before Best Effort policy value 65001 Use the show lecselanpolicy command to show the newly created ELAN join policy SmartSwitch show lecselanpolicy Ind...

Страница 32: ...this type of configuration a SmartSwitch running LANE services LECS LES and BUS resides on one side of an ATM WAN while SmartSwitch ATM switches on the other side of the WAN provide connectivity for L...

Страница 33: ...ts of the same physical port of the switch running LANE services Because these requests are appearing on multiple logical entities multiple virtual ports this requires the BUS to be capable of logical...

Страница 34: ...icasting Multiple PVP connections terminated on the LANE server switch through virtual ports on different physical ports Any SmartSwitch ATM switch physical BUS multicasting Multiple PVP connections t...

Страница 35: ...ltiple LECSs alleviates the bottleneck of a single LECS supporting all clients on all ELANs Under LNNI a client requesting a call setup is serviced by the LECS LES and BUS on the switch that it s dire...

Страница 36: ...S BUS on its directly connected switch This keeps the client s call setups local to his directly attached switch and allows other LES BUSs on other switches free to service the call setups of their lo...

Страница 37: ...ATM switch is performed by executing the following basic steps Shut down all LANE services LECS LES and BUS Configure LNNI Enable LNNI Start LANE services The following is an example of enabling LNNI...

Страница 38: ...LECSID for SW2 SW2 set lnniinfo LECSID 1 1 On SW2 LECSID will be one SW2 Note The default LECID 1 indicates that the LECS is not used on this switch The default value 1 is used as the LECID on switche...

Страница 39: ...01 elan1 ConnectMethod SVC ELANType 802 3 Multipoint YES MTU 1516 ErrorLogEnable NO MinimumTDEnable NO Distribute PROXY SW2 7 On SW1 enter the show elan 1 command to obtain the ATM address of the LECS...

Страница 40: ...00 00 1d a3 87 0b 01 SW2 The LECSs on switch SW1 and SW2 are now configured for LNNI and are running redundantly If for example LANE services goes down on SW1 its clients can rejoin the ELAN by regist...

Страница 41: ...LECS LECS shutdown SW3 2 On switch SW3 use the add buselan command to associate this switches BUS with the ELAN on switches SW1 and SW2 elan1 SW3 add buselan ELANNumber 0 1 ELANName ELAN001 elan1 Con...

Страница 42: ...er information is not shared As a result client connects may be slowed by the client s need to broadcast to find the LES with the appropriate ARP information 7 On SW3 use the start les command to acti...

Страница 43: ...00 00 00 00 00 00 00 A3 87 0B 00 00 1D A3 87 0B 01 Type LES Alive Time secs 27 Locally Attached Yes Config Direct VCC 0 59 Server ID 0x0001 LECID Range 0x0400 0x07FF ATM Address 39 00 00 00 00 00 00 0...

Страница 44: ...2 26 SmartSwitch ATM User Guide Creating an Emulated LAN IP Over ATM and LANE...

Страница 45: ...ault values which can be changed The following describes the formulae used in creating these values Default Peer Group ID 50 39 00 00 00 00 00 00 00 00 00 00 00 00 Default Group Level 80 50 hexadecima...

Страница 46: ...iew SmartSwitch ATM switch PNNI node parameters For example SmartSwitch show pnninode NodeIndex 1 Node Index 1 Node Level 80 Node Id 50 a0 39 00 00 00 00 00 00 00 00 00 14 59 00 00 20 d4 14 59 7f 00 L...

Страница 47: ...of your network there are advantages to dividing your PNNI network into different peer groups and levels The basic steps for creating multiple peer groups and multiple levels are as follows Set the pe...

Страница 48: ...SWA1 set pnnipeergroupid NodeIndex 1 PeerGroupId 50 39 00 00 00 00 00 00 00 00 00 00 00 00 50 39 00 00 00 00 00 00 00 00 01 00 00 00 Change the tenth byte to 01 Console You have changed the node confi...

Страница 49: ...7A2 1 206 61 237 20 2WayInside Lowest Level Horizontal Link 2 7A3 1 206 61 237 19 2WayInside Lowest Level Horizontal Link SWA3 4 Select switch SWA3 to be the PGL of group A and switch SWB3 to be the...

Страница 50: ...00 20 d4 28 c1 ff 00 Peer Group Leader 50 a0 39 00 00 00 00 00 00 00 00 00 a3 87 0b 00 20 d4 28 c1 ff 00 Active Parent Node Id 48 50 39 00 00 00 00 00 00 00 00 00 00 00 01 00 20 d4 28 c1 ff 00 SWA3 8...

Страница 51: ...ugh any physical link that connects the two groups For example if a second physical link is made between two other switches in groups A and B for instance between SWA1 and SWB2 and if the physical lin...

Страница 52: ...d 4 Perform steps 2 and 3 for switches with the same role in the other level 72 parent groups These steps create a grandparent group at level 64 and establishes a virtual link between the LGNs that re...

Страница 53: ...command to view the current administrative weights For example SmartSwitch show pnniinterface PortNumber ALL Port Admin Wt Admin Wt Admin Wt Admin Wt Admin Wt Aggregation Number CBR RTVBR NRTVBR ABR...

Страница 54: ...cal link Using different token values for physical links causes the links to be represented and advertised as separate logical links within the parent group Continuing with the earlier example of mult...

Страница 55: ...ime is designed as a buffer in case of minor latency By waiting three seconds before releasing resources and tearing down the connection a minor latency occurrence less than three seconds will not bri...

Страница 56: ...wing on both switches SmartSwitch set linkmonitortimeout TimeoutValue 3 0 Make the timeout instantaneous SmartSwitch If a traffic lapse occurs on one of the links that link s port immediately frees up...

Страница 57: ...ice that supports only IISP routing For example 1 Physically connect port 5b2 of the SmartSwitch 6500 to the IISP device 2 Enter show netprefix to determine the netprefix of port 5b2 on the SmartSwitc...

Страница 58: ...PNNI 4 39 00 00 00 00 00 00 00 00 00 28 e9 80 I PNNI 5 39 00 00 00 00 00 00 00 00 00 28 f5 00 I PNNI 6 7B4 47 00 79 00 00 00 00 00 00 00 00 00 00 00 a0 3e 00 00 01 I MGMT 7 5B2 52 00 00 00 00 00 00 00...

Страница 59: ...must contain a route to switch A over the physical link that connects the two switches Note Dotted lines in the diagrams below represent one way IISP routes to the devices pointed to by the arrowhead...

Страница 60: ...SP route has failed For example two SmartSwitch ATM switches are connected with parallel IISP links To configure the switches to immediately recognize any lapse in traffic as a downed link enter the f...

Страница 61: ...0 00 11 22 33 44 55 00 3 Use the add atmroute command to create a static UNI route that specifies port 7A2 and the adapter s new ATM address SmartSwitch add atmroute PortNumber 7a2 AtmAddress 39 00 00...

Страница 62: ...fer in case of minor latency By waiting three seconds before releasing resources and tearing down the connection a minor latency occurrence less than three seconds will not bring down the route Howeve...

Страница 63: ...rol the use of a route for call set ups By default a metric assigns the lowest value 5040 to the AdminWt parameter Values less than 5040 for example 500 are considered to have greater administrative w...

Страница 64: ...CLP 2 AdminWt 5040 200 MaxCellRate NotUsed 1000 AvailableCellRate NotUsed 750 MaximumCellTransferDelay NotUsed CellDelayVariation NotUsed CellLossRatioForCLP 0 NotUsed CellLossRatioForCLP 0 1 NotUsed...

Страница 65: ...ting performance is inadequate for routing between VLANs If you need to create routes between VLANs on your ATM SmartSwitch use a router equipped with an ATM interface Consult Cabletron Customer Suppo...

Страница 66: ...on gateway flags Refcnt Use Interface 127 0 0 1 127 0 0 1 5 0 0 lo0 SmartSwitch Figure 4 3 IP routing through SW1 for connectivity to the Ethernet network Note The NMS must also contain a route that s...

Страница 67: ...examples will work with all other SmartSwitch ATM switches however the port numbering would be different For example instead of port 7A1 SmartSwitch 6500 the port might be A1 on a 2500 6A000 or 9A100...

Страница 68: ...s VCI Port1 to Port2TrafficDescriptorIndex 2 We use our traffic descriptor Port2 to Port1TrafficDescriptorIndex 2 SmartSwitch The example above creates a PVC between ports 7a1 and 7b2 with VPCI VCI 0...

Страница 69: ...fficType UBR This is the backward traffic descriptor TrafficDescriptorType 11 PCRCLP01 100 0 Set PCRCLP01 to zero QOSCLASS 0 AalType 5 SmartSwitch 2 Use show trafficdescriptor to obtain the new traffi...

Страница 70: ...9A100 the CPU port is B4 however as with the SmartSwitch 6500 the value CPU can also be used Follow these instructions to connect an end node to an ATM SmartSwitch s local client through a point to p...

Страница 71: ...for VPIs MaxVpiBits parameter Note that a PVP cannot use VPI zero Consequently the number of VPI bits must be greater than zero 0 on both ports Determine the number of Available VPIs from the MaxVpiB...

Страница 72: ...er 7b1 Specify the second port Port 2 VPI 1 Specify its VPI Port1 to Port2TrafficDescriptorIndex 2 Set the traffic descriptors Port2 to Port1TrafficDescriptorIndex 2 SmartSwitch Note Point to multipoi...

Страница 73: ...igure 5 1 For example to terminate a PVP with VPI number of 3 physically connect it to a port that contains a virtual port with virtual port number equal to three 7a1 3 5b2 3 A1 3 C5 3 and so on Figur...

Страница 74: ...rtual ports Note Signaling is usually not used on physical ports on which virtual ports are created However you can leave signaling active on the physical ports if necessary Use the MaxVpiBits paramet...

Страница 75: ...Status up SigType autoConfig nnipvc Turn off signaling by setting SigType to nnipvc SigRole network InterfaceType private MaxVpiBits 0 Default MaxVpiBits 0 MaxVciBits 13 Default MaxVciBits 13 MaxSvcVp...

Страница 76: ...minStatus up IlmiAdminStatus up SigType autoConfig nnipvc Turn off signaling SigRole network InterfaceType private MaxVpiBits 0 4 Available VPIs are set to 24 1 16 1 15 VPIs MaxVciBits 9 MaxVciBits de...

Страница 77: ...upports both soft or smart PVC and soft PVP connections Soft PVCs and PVPs are used to create PVC and PVP connections between ports on separate switches that are separated by a PNNI network Normally P...

Страница 78: ...on the target switch as its end point 5 4 3 Creating a soft PVC The following is a step by step example of creating a soft PVC from port 7a1 on the source switch to port 6b3 on the target switch The t...

Страница 79: ...00 00 00 00 00 00 00 a3 87 0b 00 20 d4 34 77 ff I MGMT 10 39 00 00 00 00 00 00 00 00 00 bf ba 26 I PNNI 11 CPU 47 00 79 00 00 00 00 00 00 00 00 00 00 00 a0 3e 00 00 01 I MGMT 12 47 00 79 00 00 00 00 0...

Страница 80: ...ED the specified target vpi vci is set at the target switch If ANY is specified the soft PVC uses the first available vpi vci pair it finds on the target switch If ANY is specified enter the show spvc...

Страница 81: ...d in the ATM routing table Use the show atmroute command to check which addresses are currently defined on the target switch SmartSwitch show atmroute Num ALL Num Port Number ATM Address Type Proto 1...

Страница 82: ...the add trafficdescriptor command to create traffic descriptors for the forward and reverse directions of the connection See Section 5 1 1for information about traffic descriptors 6 On the source swi...

Страница 83: ...Soft PVC and PVP Connections Enter the show spvp command on the target switch to see the soft PVP and its current state SmartSwitch show spvp PortNumber ALL 7a1 SourceVpi 0 3 Port Src VPI Leaf Ref Op...

Страница 84: ...5 18 SmartSwitch ATM User Guide Soft PVC and PVP Connections Virtual Ports and Static Connections...

Страница 85: ...e category for a connection Buffer memory allocation Threshold settings for anti congestion routines Caution Do not change traffic control settings unless you have expert level experience with ATM swi...

Страница 86: ...0872 5436 0 2052 0 0 5 2 CBR 2 1 0 100 0 0 0 0 0 5 176 NRTVBR 2 1 0 1585 0 0 0 0 0 5 SmartSwitch Note You cannot use the default traffic descriptors for user defined PVCs All traffic descriptors used...

Страница 87: ...ame service category 6 1 2 Call Admission Control Policy Call Admission Control CAC policy defines the bandwidth allocation scheme used by the CAC when setting up connections ATM SmartSwitches offer t...

Страница 88: ...to change the CAC policy to moderate or conservative SmartSwitch set caceqbwallocscheme PortNumber 7a1 SeriveCategory CBR ubr AllocScheme LIBERAL moderate SmartSwitch Use the set cacserviceclassbw com...

Страница 89: ...nIndex MinValue MaxIndex MaxValue 7A1 1 CBR 10 64 15 1024 7A1 2 RTVBR 8 256 13 4096 7A1 3 NRTVBR 8 256 13 4096 7A1 4 ABR 8 256 12 8192 7A1 5 UBR 8 256 12 8192 PortID QueueId ServiceClass MinIndex MinV...

Страница 90: ...TVBR 8 256 13 4096 7A3 3 NRTVBR 8 256 13 4096 7A3 4 ABR 8 256 12 8192 7A3 5 UBR 8 256 12 8192 SmartSwitch CBR on port 7a3 is currently using 64 MinIndex 10 as its minimum threshold Use the show minmax...

Страница 91: ...trafficcongestion Switch Traffic Congestion Parameters Low EPD Threshold 209715 cells High EPD Threshold 104857 cells CLP1 Discard Threshold 131072 cells RM Cell Marking Enable OFF EFCI Cell Marking E...

Страница 92: ...6 8 SmartSwitch ATM User Guide Traffic Management Capabilities Traffic Management...

Страница 93: ...different with your TFTP server software The following is an example of a hot upgrade SmartSwitch update firmware ServerIP 206 61 237 127 IP address of TFTP server Path public server ima builds luxor...

Страница 94: ...uivalent file with the ATM SmartSwitch MAC address and IP address You may also need to specify the path to the image file to be downloaded 6 From the terminal connection enter the reboot command 7 Whe...

Страница 95: ...ly after a reboot and before the switch firmware is loaded Consequently the bootline commands can be used only through a terminal connection Perform the following steps to gain access to the bootline...

Страница 96: ...hows whether POST is set to run at switch start up none df Download Firmware Downloads firmware images from a TFTP Bootp server Different components of the switch firmware are downloaded depending on...

Страница 97: ...M CPU to the master none Table 7 1 Bootline commands Continued Command Action Parameters initial boot routines boot image 0 boot image 1 MAC addresses POST diagnostics ATM SmartSwitch operating firmwa...

Страница 98: ...TFTP Bootp server 6 From the terminal connection enter the reboot command 7 When the following message appears Press any key to exit to bootline prompt stop the countdown by pressing any key The bootl...

Страница 99: ...ion 2 Connect both the TFTP Bootp server and the ATM SmartSwitch to your Ethernet network Make sure that the TFTP Bootp server can be reached by the ATM SmartSwitch Ethernet interface 3 Connect a dumb...

Страница 100: ...a dumb terminal or workstation running terminal emulation software to the ATM SmartSwitch Terminal port 4 Copy the ATM SmartSwitch operating firmware image into the appropriate location on the TFTP B...

Страница 101: ...nds BootlineCommands Validity checks of the Switch Software Downloaded file All Validity checks OK Programming downloaded image into Switch Software section please wait New Switch Software programmed...

Страница 102: ...7 10 SmartSwitch ATM User Guide Bootline Commands Firmware Upgrades and Bootline Commands...

Страница 103: ...ress or range of addresses and or a destination address or range of addresses and the action to be taken admit or deny 2 Create and name a filter set whose members are existing filters 3 Assign a filt...

Страница 104: ...SmartSwitch 2 Use the add atmfilterset command to create a filter set that uses the filters domain1 and domain2 SmartSwitch add atmfilterset FilterSetName SET1 Denied_domains FilterName domain1 Filter...

Страница 105: ...ent 1 access to client 2 by rejecting the call set up to client 2 However once the call fails client 1 resorts to broadcasting to client 2 through the ELAN s BUS In turn the BUS forwards the broadcast...

Страница 106: ...he high precision clock signal is specified as the network source using the set networkclock command When set the port is essentially placed in loopback mode however the port also places the incoming...

Страница 107: ...is on the ATM SmartSwitch to check the local client Does the client have the correct IP address Is the subnet correct Is the ATM address correct Is the server type correct Check end node configuratio...

Страница 108: ...mand 3 Check IP routes and addresses Use show route command to check the ATM SmartSwitch route table Are the destination addresses correct for the specified gateways Are there any routing loops Are on...

Страница 109: ...itch and the other switch are in the same peer group The ATM SmartSwitch and the other switch are is different peer groups Use the following procedures to diagnose and resolve PNNI connectivity proble...

Страница 110: ...ESTION If the bandwidth of your ATM SmartSwitch begins to decrease and if connections are being lost or packets are being dropped at a high rate it s possible that your switch is becoming congested Co...

Страница 111: ...nd and take the default of all Is the number of cells dropped increasing for this port and quickly decreasing for all other ports If yes proceed to the Port Congestion section If no continue 9 Is the...

Страница 112: ...Customer support If yes continue Enter the show cacinfo command for this port Is the Allocated Bandwidth less than the Cell Reception Rate obtained from show pvc d or show svc d in step 6 If no go thr...

Страница 113: ...ts command to view a list of the currently logged events For example SmartSwitch show events Index ALL 0 33554474 MAJOR EVENT 000 00 04 311 LES ReadServerConfig Unable to open config file les db 1 335...

Страница 114: ...tablish SAAL connection Port ID 0x01c81000 T309 10000 3 117506049 024 01 54 430 More space q Alarms are displayed in the following format Alarm number The index number of the alarm in the circular buf...

Страница 115: ...edump EnableCoreDump n y y to enable core dump feature ServerIP 204 95 77 240 IP address of my TFTP server CoreDumpFile tftpboot bobr core full path name for core dump files userName bobr login name o...

Страница 116: ...15 00000008 d2000000 Core Dump Common DRAM dumped to tftpboot bobr core_cmn CPU DRAM dumped to tftpboot bobr core_cpu ffffffff ffffffff ffffffff ffffffff d2000010 ffffffff ffffffff ffffffff ffffffff d...

Страница 117: ...t MIB Hierarchy The MIB structure is logically represented by a tree hierarchy see Figure A 1 The root of the tree is unnamed and splits into three main branches Consultative Committee for Internation...

Страница 118: ...shown in Figure A 2 All nodes starting with zn represent Zeitnet objects The private ZeitNet MIB is represented by the object identifier 1 3 6 1 4 1 1295 or iso org dod internet private enterprise zei...

Страница 119: ...N Emulation Client information has an Object Identifier of 1 3 6 1 4 1 1295 2 3333 9 1 1 The znLecDDCount object representing the number of Data direct connections maintained by one LEC Lan Emulation...

Страница 120: ...llowing table of CSI Zeitnet proprietary MIB groups lists group name object identifier and group function Table A 1 CSI Zeitnet proprietary MIB groupings Name Object Identifier Function zeitnet 1 3 6...

Страница 121: ...3 6 1 4 1 1295 2 3333 9 1 Zeitnet LAN Emulation Group znLec 1 3 6 1 4 1 1295 2 3333 9 1 1 LAN Emulation Client Specific znLes 1 3 6 1 4 1 1295 2 3333 9 1 2 Lan Emulation Server Specific znBus 1 3 6 1...

Страница 122: ...conformance to ATM standards for the ATM SmartSwitch includes the following exceptions Non Conformance atmInterfaceIlmiVpi Read only atmInterfaceIlmiVci Read only aal5VccTable Not supported atmSvcVcCr...

Страница 123: ...ommand to find the IP address of the ATM SmartSwitch An NMS can use this IP address to reach the ATM SmartSwitch through Ethernet An NMS can also manage an ATM SmartSwitch through one of its ATM ports...

Страница 124: ...ands update firmware backup restore reboot A 2 2 Default Community Strings The following is a list of the default community strings used by the ATM SmartSwitch public Used for all standard SNMP commun...

Страница 125: ...enter is available Monday through Friday 8am to 8pm Eastern Time by calling 603 332 9400 B 2 FAX SERVICE You can fax support questions to us any time at 603 337 3075 B 3 ELECTRONIC SERVICES You can co...

Страница 126: ...hes for verified reported software issues B 7 REPAIR SERVICES Cabletron offers an out of warranty repair service for all our products at our Santa Clara Repair Facility Products returned for repair wi...

Страница 127: ...s 7 5 boot load firmware 7 6 boot load prompt 7 3 BUS 2 5 logical multicasting 2 14 physical multicasting 2 14 C Cabletron technical support B 1 CAC 6 3 allocating bandwidth 6 4 conservative 6 3 liber...

Страница 128: ...n 6 5 show pvp 5 6 show route 4 10 show spvc 5 14 show spvcaddress 5 13 show spvctarget 5 14 show spvp 5 17 show spvptraget 5 16 show switchtrafficcongestion 6 7 show trafficdescriptor 5 2 6 2 start l...

Страница 129: ...4 4 IISP routes 4 1 IISP routing considerations 4 2 IISP routing example 4 3 ILMI 4 6 over PVPs 5 6 ILMI 4 0 5 9 internet MIB hierarchy A 1 IP over ATM 2 1 9 1 ARP server 2 1 2 2 ARP table 2 2 ATM add...

Страница 130: ...ions A 6 MIB groupings CTRON A 5 zeitnet A 4 znBus A 5 znCacStats A 5 znCommonObjs A 5 znConfig A 5 znCpuPortTable A 5 znEventAlarmTable A 5 znEventTable A 5 znIOModuleTable A 5 znIpAtm A 4 znIpAtmCli...

Страница 131: ...port clock 8 3 loopback 8 3 port clock configuration 8 3 port clocking local 8 3 network 8 3 port config MaxVpiBits 5 2 port congestion 9 5 PVC available VPIs 5 2 MaxVpiBits 5 2 soft 5 11 PVCs 5 1 ba...

Страница 132: ...5 16 target VPI 5 16 swms 7 5 T target ATM address 5 13 target VPI VCI 5 14 technical support B 1 electronic services B 1 fax service B 1 hardware warranty B 2 placing a support call B 1 repair servi...

Страница 133: ...1 Upgrading and Changing Firmware 7 1 V VCI 5 2 viewing alarms 9 7 viewing events 9 7 virtual port 5 7 root port 5 7 virtual ports 5 7 assigning 5 7 assigning VPIs 5 8 Available VPIs 5 8 Base VPI 5 8...

Отзывы: