![Cabletron Systems SmartSTACK 100 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/cabletron-systems/smartstack-100/smartstack-100_user-manual_3420647052.webp)
3-6
Configuring Your ELS100-16TX
Using LCM to enable bridging for a port or port range, at the LCM
prompt:
1. Type
bridge [PORT-RANGE [{off|on|noBPDU}]]
For example,
bridge 2 on
would enable bridging on port 2.
LCM responds:
3.3 DISABLING BRIDGING
To turn off the bridging function for a port or port range, at the
LCM prompt:
1. Type
bridge [PORT-RANGE] off
For example,
bridge 2 off
would disable bridging on port 2.
LCM responds:
3.4 DISPLAYING BRIDGING FUNCTIONS
To display the bridging functions that are enabled for all ports, at
the LCM prompt:
1. Type
bridge
LCM responds with a list of all ports and the bridging function
that is enabled. For example, typing
bridge
would display the
bridging status for all ports.
Port 2 bridging: Transparent Bridging
Port 2 bridging: Off