7

FLNK

8

FLNK

FLNK

10

FLNK

INS

11

FLNK

INS

12

RX

TX

RX

TX

RX

Circuit Card

Card Guides

Metal Back-Panel

Jack for ESD 
wrist strap

Warning:

Ensure that the circuit card is between the card guides.

Lock down the top and bottom plastic tabs 

at the same time, applying even pressure.

Содержание MMAC-Plus 9H531-18

Страница 1: ...SmartSwitch 9000 9H531 18 and 9H532 18 18 Port Fast Ethernet Module User s Guide 9033185 01...

Страница 2: ......

Страница 3: ...This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against...

Страница 4: ...f the Program is exported from the United States pursuant to the License Exception CIV under the U S Export Administration Regulations You agree thatYou are a civil end user of the Program and agree t...

Страница 5: ...SYSTEMS 603 332 9400 Attn Legal Department 1 LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement...

Страница 6: ...THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR C...

Страница 7: ...ereof if such foreign produced direct product is subject to national security controls as identified on the U S Commerce Control List or is subject to State Department controls under the U S Munitions...

Страница 8: ...1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment pa...

Страница 9: ...2 6 The Reset Switch 2 8 Cabling Requirements 2 9 10BASE T Network 2 9 100BASE TX Network 2 9 100BASE FX Network 2 9 1000BASE SX 1000BASE LX Network 2 9 Chapter 3 Technical Overview SmartSwitch Archit...

Страница 10: ...5 2 Service 5 2 Physical 5 2 Dimensions 5 2 Weight 5 2 Environment 5 2 Appendix A GPIM Specifications GPIM 01 Specifications 1000Base SX A 1 GPIM 09 Specifications 1000Base LX A 2 Physical and Environ...

Страница 11: ...bit Ethernet ports operate only in full duplex mode and operate only at 1000 Mbps Network management information is available through a variety of methods All information based on Simple Network Manag...

Страница 12: ...Cabletron WebView a browser based utility There is no software to install as this management capability is built into each module For more information see the Cabletron Systems WebView User s Guide Co...

Страница 13: ...1 3 Introduction Figure 1 1 The 9H531 18 and 9H532 18 Module FAST ENET 9H532 18 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 FAST ENET 9H531 18 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17...

Страница 14: ...rface if a broadcast threshold is crossed Broadcast Suppression Broadcast Suppression enables a user to set a desired limit of receive broadcast frames per port per second to be forwarded out the othe...

Страница 15: ...an 802 1Q switch Standards Compatibility The 9H531 18 and 9H532 18 are fully compliant with the IEEE 802 3u 802 3z 802 3x 802 1Q and 802 1p standards The 9H531 18 and 9H532 18 provide IEEE 802 1D Spa...

Страница 16: ...RFC 1573 IETF Bridge MIB RFC 1493 and a host of other Cabletron Enterprise MIBs LANVIEW LEDs The 9H531 18 and 9H532 18 module uses LANVIEW the Cabletron Systems built in visual diagnostic and status m...

Страница 17: ...s Global Call Center Before calling the Cabletron Systems Global Call Center have the following information ready Your Cabletron Systems service contract number A description of the failure Phone 603...

Страница 18: ...d revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known...

Страница 19: ...ESD 3 Carefully examine the module checking for damage If any damage exists DO NOT install the module Contact Cabletron Systems Global Call Center immediately User Accessible Components Figure 2 1 sh...

Страница 20: ...Installing the Module 2 2 Figure 2 1 User Accessible Components SMB 1 PROM Flash SIMM Socket 32mb DRAM i960 Processor DIP Switch Boot PROM 1 2 3 4 5 6 7 8...

Страница 21: ...sses subnet masks default gateway default interface SNMP traps bridge configurations and module specific configurations in NVRAM To clear these parameters toggle this switch and then reset the module...

Страница 22: ...his time this process may be stopped by resetting the module Resetting is done by pushing the reset button on the module power cycling the chassis or removing the module from the chassis and re insert...

Страница 23: ...the orientation against Figure 2 2 Push the GPIM back until the 20 pin port engages the GPIM The latch mechanism engages when the GPIM connector seats properly in the port Figure 2 3 Installing a GPI...

Страница 24: ...for the ESD wrist strap located in the lower right corner of the SmartSwitch 9000 chassis shown in Figure 2 4 3 Slide the module into the slot and lock down both the top and bottom plastic tabs as sh...

Страница 25: ...8 FLNK FLNK 10 FLNK INS 11 FLNK INS 12 RX TX RX TX RX Circuit Card Card Guides Metal Back Panel Jack for ESD wrist strap Warning Ensure that the circuit card is between the card guides Lock down the t...

Страница 26: ...module or restarting the module To reset the i960 processor press the reset switch twice within three seconds To shut down the module press and hold the reset switch down for three or more seconds To...

Страница 27: ...een 85 and 111 ohms for 10 and 100 Mbps operation The device at the other end of the twisted pair segment must meet IEEE 802 3u 100BASE TX Fast Ethernet network requirements for the devices to operate...

Страница 28: ...Installing the Module 2 10...

Страница 29: ...e to adhere to IEEE 802 1D DEC or none The default Spanning Tree Algorithm is 802 1D When operating in SecureFast switch mode all filtering forwarding decisions are made on a DA SA pair and its in and...

Страница 30: ...I N B A B i960 Processor Smart Switch Fabric INB ASIC SMB 1 SMB 10 Ethernet Controller Diagnostic Controller SmartSwitch 9000 Backplane Front Panel Ports 16 INB ASIC Octal Mac Octal Mac DC DC Convert...

Страница 31: ...that share this bus to ensure the validity of SMB 1 In the event a failure is detected on SMB 1 the SMB 10 may be used as an alternate communication channel SMB 10 Bus The SMB 10 is a 10 Mbps manageme...

Страница 32: ...he system power bus to the necessary operating voltages for its host network services module The diagnostic controller monitors and controls the operation of the DC DC converter INB Interface Each mod...

Страница 33: ...ENET 9H532 18 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 System Status INB Transmit INB Receive LED Mode Switch GPIM Transmit GPIM Receive DPX SPD RX TX DPX SPD RX TX Mode Switch in UP Position Mod...

Страница 34: ...i e one port may be bad Yellow Green Booting Module is performing its boot process Red Reset Module is resetting Red Blinking Failed Fatal error Off Power off Module powered off Table 4 2 INB Receive...

Страница 35: ...k activity port enabled flashing to steady on indicates rate Red Fault Off No link port disabled Table 4 5 Port Transmit LEDs LED Color State Green Flashing Data activity flashing to steady on indicat...

Страница 36: ...ink no activity Port enabled Green Flashing Link port disabled Yellow Flashing Link activity Port enabled Red Diagnostic failure Off No link no activity Port enabled or disabled Table 4 8 DPX Status L...

Страница 37: ...8 MB Flash Memory expandable to 16 MB 32 MB DRAM local 4 MB Memory shared Network Interfaces 16 fixed RJ45 UTP connectors or 16 MT RJ multimode fiber optic connectors 2 modular Gigabit GPIM uplinks Pe...

Страница 38: ...nvironment Operating Temperature 5 to 40 C 41 to 104 F Storage Temperature 30 to 73 C 22 to 164 F Relative Humidity 5 to 90 non condensing Safety UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EE...

Страница 39: ...the GPIM 09 supports both multimode and single mode SMF fiber cable GPIM 01 Specifications 1000Base SX The following specifications for the Gigabit Ethernet GPIMs listed in Table A 1 though Table A 7...

Страница 40: ...11 5 dBm 9 5 dBm Receive Sensitivity 20 dBm 20 dBm 20 dBm Link Power Budget 8 5 dBm 8 5 dBm 10 5 dBm Modal Bandwidth 1300 nm Range 62 5 m MMF 500 MHz km 2 550A Meters 50 m MMF 400 MHz km 2 550A Meter...

Страница 41: ...pliance The GPIMs meet the following safety and electromagnetic compatibility EMC requirements Table A 7 Regulatory Compliance Eye Safety fiber GPIMs only FDACDRH 21 CFR 1040 Class 1 IEC 825 Issue 1 1...

Страница 42: ...GPIM Specifications A 4...

Отзывы: