![Cabletron Systems MicroMMAC-24E Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/cabletron-systems/micrommac-24e/micrommac-24e_installation-manual_3346348068.webp)
EPIM-C
MicroMMAC Installation Guide
Page B-5
B.4 EPIM-C
The EPIM-C supports thin coaxial cabling and is equipped with an
internal Cabletron Systems TMS-3 transceiver. Use the TERM switch on
the front of the EPIM-C to set the internal 50 Ohm terminator. This
eliminates the need to connect the port to a T-connector and terminator.
Figure B-4 shows the settings for the terminator switch.
Figure B-4
EPIM-C
Connector Type
BNC receptacle with gold center contact for use with BNC type
T-connectors and RG58 thin coaxial cable.
Grounding
The BNC port of the EPIM-C is not connected to earth ground.
Connecting a thin coaxial segment to earth ground at more
than one point could produce dangerous ground currents.
EPIM-C
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)
TERM
149034