Chapter 3: ROM Monitor Commands
3-18
Micro-CS Installation Guide
If the unit passes this test, the console displays PASSED. If the Micro-CS
fails, the console displays an error message. Failing this test indicates that
the Micro-CS failed to communicate with the MicroMMAC. Contact
Cabletron Systems Technical Support.
3.2.12
option_key
The option_key command loads an option key from the ROM monitor.
The command syntax is:
option_key [–d ]
The option_key command display looks like this:
The option_key
–d
command displays the current settings:
3.2.13
ping
The ping command sends an Internet Control Message Protocol (ICMP)
mandatory ECHO_REQUEST datagram to elicit an ICMP
ECHO_RESPONSE from a host or gateway. ECHO_REQUEST
datagrams (pings) have an IP and ICMP header, followed by a structured
time value and an arbitrary number of pad bytes that fill out the packet.
The syntax for this command is:
ping host_ip_address [data_size] [npackets]
The host_ip_address entry is the Internet address of the host or gateway
from which you wish to elicit a response.
The optional data_size entry is the number of bytes sent in a datagram
packet. The default value is 64 and the maximum value is 1024.
monitor:: option_key
Enter option_key [<uninitialized>]::
monitor:: option_key -d
option_key: <uninitialized>
Содержание MicroMMAC 22ES
Страница 2: ......
Страница 8: ...vi Micro CS Installation Guide...
Страница 12: ...Contents iv Micro CS Installation Guide...
Страница 22: ...Chapter 1 Introduction 1 10 Micro CS Installation Guide...
Страница 32: ...Chapter 2 Micro CS Installation 2 10 Micro CS Installation Guide...
Страница 72: ...Chapter 4 Troubleshooting Procedures 4 14 Micro CS Installation Guide...
Страница 82: ...Appendix C Flash Upgrade Instructions C 4 Micro CS Installation Guide...
Страница 92: ...Index 4 Micro CS Installation Guide...