MCC-CRIO SETUP
5-5
Connecting The RI/RO Ports To The RI/RO Ports Of Other Vendors
You must disable autowrap to connect the RI/RO ports to the devices of
other vendors.
Set Switch 1 On and Switch 3 Off to connect the RI of the MCC-CRIO
to the RO of a non-Cabletron device.
Set Switch 2 On and Switch 4 Off to connect the RO of the MCC-CRIO
to the RI of a non-Cabletron device. (See
Table 5-2
.)
Table 5-2
Switch Settings For Connecting Cabletron RI/RO Devices
SW1 Settings
1
On - Enable RI port
2
On - Enable RO port
3
On - Enable autowrap on RI (for connection to Cabletron devices)
4
On - Enable autowrap on RO (for connection to Cabletron devices)
Table 5-3
Switch Settings For Connecting The MCC-CRIO RI/RO Ports To
Other Vendor’s Devices
SW1 Settings
1
On - Enable RI port
2
On - Enable RO port
3
Off - Disable autowrap on RI (for use with other vendor’s devices)
4
Off - Disable autowrap on RO (for use with other vendor’s devices)
!
CAUTION
If autowrap is disabled, connecting a cable to the RI/RO port
may cause a beaconing condition before the cable is
completely attached. To avoid this condition connect the cable
before you insert the CM into the MCC-16, or perform the
connection with the MCC-16 shut off.
Содержание MCC-16
Страница 1: ...MCC 16 TOKEN RING MEDIA CONVERSION CENTER USER S GUIDE ...
Страница 2: ......
Страница 20: ...INTRODUCTION 1 6 ...
Страница 36: ...INSTALLATION 2 16 ...
Страница 56: ...MCC DFL SETUP 4 14 ...
Страница 64: ...MCC CRIO SETUP 5 8 ...
Страница 72: ...MCC D2PM SETUP 6 8 ...
Страница 82: ...CABLING B 8 ...
Страница 86: ...MEDIA SPECIFICATIONS C 4 ...
Страница 90: ...INDEX IX 4 ...