SPECIFICATIONS
Page 4-7
Use the following power consumption numbers when determining if a
particular MMAC has enough power to support your configuration.
FDCMIM-04 (SN 0568):
6.8 Amp at 5 Vdc
FDCMIM-04 (all others):
4.1 Amp at 5 Vdc
FDCMIM-08 (SN 0569):
11.8 Amp at 5 Vdc
FDCMIM-08 (all others):
7.0 Amps at 5 Vdc
FDCMIM-24:
5.0 Amp at 5 Vdc
FDCMIM-28:
9.0 Amp at 5 Vdc
FDCMIM-34:
3.9 Amps at 5 Vdc
FDCMIM-38:
6.6 Amps at 5 Vdc
FDCMIM-44:
5.0 Amps at 5 Vdc
FDCMIM-48:
9.0 Amps at 5 Vdc
Note: When calculating the total heat output of an MMAC hub, we
recommend that you consider the maximum potential heat output of the
MMAC power supplies rather than the heat output of the individual
MIMs within the hub. This approach ensures a more reliable heat
output total to use in long range facilities planning.
Environment
Storage temperature:
-40
°
C minimum
85
°
C maximum
Operating temperature:
5
°
C minimum
40
°
C maximum
Operating humidity:
5% to 95% non-condensing
Safety
This unit meets the safety requirements of UL 1950, CSA C22.2
No. 950, and EN 60950; the EMI requirements of FCC Class A and
EN 55022 Class A; and the EMC requirements of EN 50082-1.
Note: It is the responsibility of the person who sells the system to which
the FDCMIM will be a part to ensure that the total system meets allowed
limits of conducted and radiated emissions.