25
9T122-08 Module Specific Information
¥
Remove/Alarm
- This is the highest level of ring security. In this security mode,
the ring is locked to new stations. The Remove/Alarm mode sends a ÒRemove
MAC FrameÓ command to a new station attempting to enter the ring, and a
trap/alarm to the NMS informing it of the action taken. If, after three attempts,
the station cannot be removed from the ring, remove alarm sends a trap/alarm
ÒRemove FailureÓ to the NMS, informing it that the station could not be
removed.
Selecting a Security Mode
To select a Security Mode:
1. Use the arrow keys to highlight the
Security Mode
Þeld.
2. Press the
Space Bar
to toggle to the desired security mode (either Disabled,
Alarm Only, or Remove/Alarm).
3. Use the arrow keys to highlight the
SAVE/EXECUTE
command, then press
the
Return
key. The selected mode of ring security becomes effective.
Viewing Previous/Next Page of Station Addresses
To view the previous/next page (if there is one) of station addresses, use the
arrow keys to highlight the appropriate range of station addresses command (for
example, [ 9-16 ]), then press the
Return
key.
Exiting the Token Ring Secured Station Configuration Screen
To exit the Token Ring Secured Station ConÞguration Screen, use the arrow keys
to highlight
RETURN
, then press the
Return
key.
If you change directly from Disabled mode to Remove/Alarm mode, all stations
that have not been added to the allowed list will be removed from the token ring.