3-14
Repeater MIM
Chapter 3: INSTALLING THE RMIM
To connect the TPRMIM-33/36 into an existing twisted pair wiring system:
1.
Connect a 50-pin feeder cable to the Champ connector on the TPRMIM. See
Figure 3-9.
2.
Attach the feeder cable to the Punch Down Block, or patch panel. If using a
TPRMIM-36, a second 50-pin feeder cable can be connected to the RMIM.
In most cases, you can connect the feeder cable directly to a Champ connector
located on the Punch Down Block. If not, you must wire the feeder cable to
the Punch Down Block using the punch down information in Appendix A.
3.
At the device end of a segment, attach the segment to a 10BASE-T compliant
Ethernet device.
4.
Check that the Link light on the 10BASE-T Ethernet device and the LNK
LED on the TPRMIM are lit. If the LEDs are unlit, perform each of the
following steps until the LEDs are lit:
a.
Check that the 10BASE-T device and the MMAC have power.
b.
Verify the cabling between the module and the 10BASE-T device.
c.
Check the cable for continuity.
If a link has not been established, contact Cabletron Systems Technical Support.
3.4.5
Connecting a Twisted Pair Segment to an EPIM-T
Before connecting a segment to the EPIM-T, check each end of the segment to
determine if the wires have been crossed over for the proper connection. If the
wires do not cross over, use the switch on the EPIM-T to internally cross over the
RJ45 port. Refer to Figure 3-10 to properly set the EPIM-T cross-over switch.
Содержание CXRMIM
Страница 2: ......
Страница 18: ...1 10 Repeater MIM Chapter 1 INTRODUCTION...
Страница 40: ...3 8 Repeater MIM Chapter 3 INSTALLING THE RMIM Figure 3 4 Installing an EPIM CXRMIM ETHERNET...
Страница 58: ...4 6 Repeater MIM Chapter 4 TESTING THE RMIMS Figure 4 4 EPIM LEDs...
Страница 68: ...A 10 Repeater MIM Appendix A Twisted Pair Wiring Tables...
Страница 78: ...Index 4 Repeater MIM Index...