background image

 

BRIM-WT1

USER’S GUIDE

 

CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505

The Complete Networking Solution™

Содержание BRIM-WT1

Страница 1: ...BRIM WT1 USER S GUIDE CABLETRON SYSTEMS P O Box 5005 Rochester NH 03867 0505 The Complete Networking Solution ...

Страница 2: ...NOTICE 0 ...

Страница 3: ...CLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright February 1994 by Cabletron Systems Inc P O Box 5005 Rochester NH 03867 0505 All Rights Reserved Printed in the United States of America Part Number 9031024 February 1994...

Страница 4: ...perator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority t...

Страница 5: ...BILITY IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT PROMPTLY RETURN THE UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND CABLETRON SOFTWARE PROGRAM LICENSE 1 LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except a...

Страница 6: ...ABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OR ON THE DURATION OR LIMITATION OF IMPLIED WARRANTEES IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU UNITED STATES GOVERNMENT RESTRICTED RIGHTS The enclosed product a was developed solely at priv...

Страница 7: ... 5 BRIM WT1 SPECIFICATIONS 3 1 6 RELATED MANUALS 4 CHAPTER 2 INSTALLATION 2 1 UNPACKING THE BRIM WT1 5 2 2 INSTALLING THE BRIM WT1 6 CHAPTER 3 LOCAL MANAGEMENT 3 1 The WAN PHYSICAL CONFIGURATION SCREEN 9 3 2 THE WAN INTERFACE CONFIGURATION SCREEN 15 CHAPTER 4 USING THE LANVIEW LEDS 4 1 BRIM WT1 LEDS 21 4 2 T1 FT1 PORT LEDS 22 4 3 SYNC PORT LEDS 23 ...

Страница 8: ...CONTENTS vi BRIM WT1 USER S GUIDE ...

Страница 9: ...d capabilities of the BRIM WT1 A general working knowledge of WAN Ethernet and IEEE 802 3 type data communications networks and their physical layer components is helpful when using the BRIM WT1 Chapter 1 Introduction outlines the contents of this manual describes BRIM WT1 features lists specifications and concludes with a list of related manuals Chapter 2 Installation describes how to install the...

Страница 10: ... services such as T1 Fractional T1 and Digital Data System DDS The BRIM WT1 extends the functionality of the MicroMMAC to include remote bridging and routing capability With the BRIM WT1 the MicroMMAC is a remote office workgroup hub providing up to 130 LAN ports of connectivity 1 4 BRIM WT1 FEATURES WAN Connectivity The BRIM WT1 is equipped with a Synchronous SYNC serial port and a T1 Fractional ...

Страница 11: ...ort see Getting Help The MicroMMAC with the BRIM WT1 installed supports the following Wide Area Network IETF MIBs RFC1406 DS1 Connection Management RFC1317 RS232 Like Connection Management RFC1471 draft PPP Link RFC1474 draft PPP Bridge RFC1315 Frame Relay LANVIEW Diagnostic LEDs Cabletron provides a visual diagnostic and monitoring system called LANVIEW with the BRIM WT1 LANVIEW LEDs help you qui...

Страница 12: ...nts of FCC Class A and EN 55022 Class A and the EMC requirements of EN 50082 1 The T1 port also meets FCC Part 68 1 6 RELATED MANUALS Use the following manuals to supplement the procedures and other technical data provided in this manual This manual references procedures in these manuals where appropriate but does not repeat them Cabletron Systems MicroMMAC User s Guide ...

Страница 13: ...cover You also need a Phillips head screwdriver to install the BRIM WT1 2 1 UNPACKING THE BRIM WT1 Unpack the BRIM WT1 as follows 1 Remove the shipping material covering the BRIM WT1 in the shipping box 2 Carefully remove the BRIM WT1 from the shipping box 3 Remove the BRIM WT1 from the protective plastic bag and set it aside to prevent damage 4 Visually inspect the BRIM WT1 If there are any signs...

Страница 14: ...rap and observe all static precautions during this procedure Failure to do so could result in damage to the BRIM WT1 or the MicroMMAC To Install the BRIM WT1 into the MicroMMAC 1 Remove the screws from the BRIM slot faceplate at the rear panel of the MicroMMAC as shown in Figure 2 1 2 Remove the screws from the two standoffs Figure 2 1 Removing the Faceplate and Standoff Screws Faceplate Standoff ...

Страница 15: ... the BRIM WT1 sits flush on the MicroMMAC connector Figure 2 2 Installing the BRIM WT1 4 Secure the BRIM WT1 to the standoffs and MicroMMAC rear panel using the four screws included with the module 5 Reattach the chassis cover to the MicroMMAC and reconnect the MicroMMAC to your network LNK TST BRIM WT STB YEL SYN RED LNK DSR TST CTS SYNC T1 FT1 ...

Страница 16: ...CHAPTER 2 INSTALLATION Page 8 BRIM WT1 USER S GUIDE ...

Страница 17: ...n screen from the Feature Selection screen use the arrow keys to highlight the WAN Physical Configuration option then press the Return key The WAN Physical Configuration screen shown in Figure 3 1 appears Figure 3 1 WAN Physical Configuration Screen SAVE WAN INT CONFIG RETURN F6 MicroMMAC WT1 LOCAL MANAGEMENT Cabletron MMW Revision xx xx xx WAN PHYSICAL CONFIGURATION 00 00 00 00 00 00 00 00 00 00 ...

Страница 18: ...e Sync Port is not the active WAN port To use X 21 or RS530 select RS422 and use the proper Interface Cable available from Cabletron See Table 1 for Cabletron Interface Cable part numbers The default setting for this field is V 35 Force CTS True Displays the source of the Clear To Send CTS signal You can toggle the selections between YES and NO The YES On setting indicates that the CTS is internal...

Страница 19: ...guration Table is all Timeslots not assigned T1 Line Coding Displays the line coding for the Full T1 line The selections toggle between INV HDLC JBZS B8ZS and OTHER The OTHER selection lets you select line coding for individual Interfaces The default setting for this field is B8ZS T1 Frame Type Displays the T1 Frame type The selections toggle between ESF and D4 The default setting for this field i...

Страница 20: ...Table allows you to configure how your MicroMMAC utilizes the T1 line The configuration table consists of 24 Timeslots which appear as 01 08 09 16 and 17 24 You must assign each Timeslot an Interface number 03 26 or 00 if the Timeslot is not used When you lease an entire T1 line you can use all 24 Timeslots the full T1 bandwidth If you lease only a fraction of the T1 the Telco carrier will tell yo...

Страница 21: ... 3 only use a fraction of the T1 but the quantity of Timeslots must match those of MicroMMAC 1 Unused Timeslots receive an Interface number of 00 Note The Interface numbers of MicroMMAC 1 and MicroMMAC 3 do not have to match Only the quantity of Timeslots must match the Telco carrier will assign the timeslots To set the Timeslot Configuration Table 1 Use the arrow keys to highlight the Active sett...

Страница 22: ...slots Note The MicroMMAC automatically assigns Interface 01 for Ethernet and Interface 02 for the SYNC port 6 Press the Return key 7 Repeat steps 4 6 to complete the configuration 8 Use the arrow keys to highlight the SAVE command 9 Press the Return key or press F6 The message Save Done appears and the changes are saved to memory 10 Use the arrow keys to highlight the T1 Timeslot View field 11 Pre...

Страница 23: ...ace Configuration screen fields and instructions for setting them Interface Number Displays Interface Numbers 02 26 Use this field to configure the Interface Numbers you assigned to the Timeslots at the WAN Physical Configuration screen This field only displays the active SYNC and T1 interfaces Data Compression Displays the status of Data Compression Select Yes to activate Data Compression or No t...

Страница 24: ...Management may assign up to 31 WAN bridge ports Note The MicroMMAC has 32 available bridge ports Ethernet is the first bridge port The remaining 31 bridge ports are available for WAN applications You can assign the 31 WAN bridge ports to the 24 interfaces in the configuration that suits your needs For example you can assign all 31 WAN bridge ports to one interface In this example the remaining 23 ...

Страница 25: ...available To configure an Interface Number 1 Use the arrow keys to highlight the Interface Number field 2 Press the Return key to select the Interface Number 02 26 you want to configure 3 Use the arrow keys to highlight the Active Protocol field 4 Press the Return key to select PPP FR or NONE Select PPP or FR to assign a Bridge Port Select NONE to remove a previously assigned Bridge Port 5 Use the...

Страница 26: ...message Save Done appears The BRIM WT1 Local Management automatically assigns an Active Port Number to the Interface number and the changes are saved to memory Setting the Max Xmit Unit Field To set the Max Xmit Unit field 1 Use the arrow keys to highlight the Max Xmit Unit field 2 Enter the desired setting 3 Use the arrow keys to highlight the SAVE command 4 Press the Return key or press F6 The m...

Страница 27: ...ical Configuration screen to OTHER To set the Line Coding field 1 Use the arrow keys to highlight the Line Coding field 2 Enter the desired setting 3 Use the arrow keys to highlight the SAVE command 4 Press the Return key or press F6 The message Save Done appears The BRIM WT1 Local Management automatically assigns an Active Port Number to the Interface number and the changes are saved to memory ...

Страница 28: ...CHAPTER 3 LOCAL MANAGEMENT Page 20 BRIM WT1 USER S GUIDE ...

Страница 29: ...bridge ports are in the non forwarding state Possible causes of this condition are redundancy detected by Spanning Tree data link layer down physical layer down or port disabled Blinking Some WAN bridge ports are in the forwarding state and some WAN bridge ports are in the non forwarding state Off All WAN bridge ports are in the forwarding state SYN Synchronous On SYNC port is active Off T1 FT1 po...

Страница 30: ...ions Check the T1 port cable Off Signal OK TST Test On Indicates that the T1 FT1 port is in the test mode Off Indicates that the T1 FT1 port is in the non test mode YEL Yellow Alarm On Indicates that the remote bridge has lost T1 Frame synchronization Check the remote bridge T1 port cable or T1 Frame Type setting Off Synchronization OK RED Red Alarm On Indicates that the bridge has lost T1 Frame s...

Страница 31: ...he DCE is ready to receive data from the BRIM WT1 or that the Force CTS True field refer to the WAN Physical Configuration screen is set to YES On Off A valid CTS is not being received from the DCE Check the cabling or check if the DCE is powered on LNK Link On Indicates that the BRIM WT1 is receiving a valid clock from the DCE Off Indicates that the BRIM WT1 is not receiving a valid clock from th...

Страница 32: ...CHAPTER 4 USING THE LANVIEW LEDS Page 24 BRIM WT1 USER S GUIDE ...