7

9E428-12/36 and 9E429-12/36 Module Specific Information

 

Switch Configuration Screen

 

The 9E428-12/36 and 9E429-12/36 Switch Configuration Screen (Figure 2), 
provides basic setup options for making a switch operational in your network.

 

Figure 2. 9E428-12/36 and 9E429-12/36 Switch Configuration Screen

                      SmartSwitch 9000  Local Management

                             Switch Configuration

    Module Name: 9E428-36                        Firmware Revision: 01.04.07

    Slot Number: 9                               BOOTPROM Revision: 01.01.01

    Switch Address:        00-00-1D-00-08-78     Type of STA:      [IEEE]

    Numbers of Ports:      37

    Port #             MAC Address               State           Status

         1             00-00-1D-00-08-78         forwarding      [ENABLED]

         2             00-00-1D-00-08-79         forwarding      [ENABLED]

         3             00-00-1D-00-08-7A         forwarding      [ENABLED]

         4             00-00-1D-00-08-7B         forwarding      [ENABLED]

         5             00-00-1D-00-08-7C         forwarding      [ENABLED]

         6             00-00-1D-00-08-7D         forwarding      [ENABLED]

         7             00-00-1D-00-08-7E         forwarding      [ENABLED]

         8             00-00-1D-00-08-7F         forwarding      [ENABLED]

     SAVE                            [  9-16 ]         EXIT        RETURN

Port # refers to the following:

Port 1 - INB

Port 2 - Front Panel Port 1

Port 3 - Front Panel Port 2

Port 4 - Front Panel Port 3

Port 5 - Front Panel Port 4

Port 6 - Front Panel Port 5

Port 7 - Front Panel Port 6

Port 8 - Front Panel Port 7

Port 9 - Front Panel Port 8

Port 10 - Front Panel Port 9, and so on.

NOTE

Содержание 9E428-12

Страница 1: ...9032034 01 SmartSwitch 9000 9E428 12 36 and 9E429 12 36 Local Management Appendix ...

Страница 2: ......

Страница 3: ...429 36 36 Ports Single Mode Fiber ST connectors The 9E428 12 and 9E429 12 Ethernet Modules are 13 port switching modules with 12 front panel Ethernet ports 1 Internal Network Bus INB backplane port The 9E428 36 and 9E429 36 Ethernet Modules are 37 port switching modules with 36 front panel Ethernet ports 1 Internal Network Bus INB backplane port Each front panel port of the 9E428 12 36 and 9E429 1...

Страница 4: ...ts the identifying number name and description of each interface Table 1 9E428 36 and 9E429 36 Module Interface Codes Interface Number Interface Name Interface Description 1 SMB1 1 Mbps System Management Bus 2 SMB10 10 Mbps System Management Bus 3 HOST i960 Host 4 LOCAL i960 Controller 5 INB Internal Network Bus 6 ENET1 Ethernet Front Panel Port 1 7 ENET2 Ethernet Front Panel Port 2 8 ENET3 Ethern...

Страница 5: ...nel Port 21 27 ENET22 Ethernet Front Panel Port 22 28 ENET23 Ethernet Front Panel Port 23 29 ENET24 Ethernet Front Panel Port 24 30 ENET25 Ethernet Front Panel Port 25 31 ENET26 Ethernet Front Panel Port 26 32 ENET27 Ethernet Front Panel Port 27 33 ENET28 Ethernet Front Panel Port 28 34 ENET29 Ethernet Front Panel Port 29 35 ENET30 Ethernet Front Panel Port 30 36 ENET31 Ethernet Front Panel Port 3...

Страница 6: ... Duplex Configuration Module Name 9E428 36 Firmware Revision 01 04 07 Slot Number 9 BOOTPROM Revision 01 01 01 PORT OPERATION MODE LINK STATUS PORT STATUS 1 STANDARD ENET No Link ENABLED 2 STANDARD ENET No Link ENABLED 3 STANDARD ENET No Link ENABLED 4 STANDARD ENET No Link ENABLED 5 STANDARD ENET No Link ENABLED 6 STANDARD ENET No Link ENABLED 7 STANDARD ENET No Link ENABLED 8 STANDARD ENET No Li...

Страница 7: ...d receive data at the same time Therefore the port is running at 20 Mbps LINK STATUS Indicates whether there is a physical connection from this port to another 10Base FL device One of the following values appears Link There is a 10Base FL link signal present there is a valid physical connection from this port to another 10Base FL device No Link There is no 10Base FL link signal present there is no...

Страница 8: ...o Full Duplex To set one Ethernet port to Full Duplex for example port 1 1 Use the arrow keys to highlight STANDARD ENET in the Operation Mode field to the right of port 1 2 Press the Space Bar until FULL DUPLEX appears in the field 3 Use the arrow keys to highlight the SAVE command on the bottom line of the screen 4 Press the Return key Setting All Ethernet Ports to Full Duplex To set all Etherne...

Страница 9: ... STA IEEE Numbers of Ports 37 Port MAC Address State Status 1 00 00 1D 00 08 78 forwarding ENABLED 2 00 00 1D 00 08 79 forwarding ENABLED 3 00 00 1D 00 08 7A forwarding ENABLED 4 00 00 1D 00 08 7B forwarding ENABLED 5 00 00 1D 00 08 7C forwarding ENABLED 6 00 00 1D 00 08 7D forwarding ENABLED 7 00 00 1D 00 08 7E forwarding ENABLED 8 00 00 1D 00 08 7F forwarding ENABLED SAVE 9 16 EXIT RETURN Port r...

Страница 10: ...ling Management has disabled this interface No traffic can be received or forwarded while the interface is disabled Learning The switch is learning this interface s network addresses The switch enters the learning state when the Transparent Database is created during start up or after being deleted or when the Spanning Tree Algorithm detects a network topology change Listening The switch is not ad...

Страница 11: ...ce Bar to toggle to the desired value Valid entries are ENABLED DISABLED Displaying Other Ports To display other ports 1 Use the arrow keys to highlight one of the following fields located at the bottom of the Switch Configuration Screen 9 16 for ports 9 through 16 17 24 for ports 17 through 24 25 32 for ports 25 through 32 33 37 for ports 33 through 37 2 Press the Return key ...

Страница 12: ...6 Port Statistics Screen SmartSwitch 9000 Local Management Port Statistics Module Name 9E428 36 Firmware Revision 01 04 07 Slot Number 9 BOOTPROM Revision 01 01 01 PORT 1 OCTETS 0 LINK STATUS No Link PACKETS 0 TOTAL ERRORS 0 PORT TYPE MMF ST COLLISIONS 0 CRC ALIGNMENT ERRORS 0 PORT STATUS ENABLED UNDERSIZE PACKETS 0 OVERSIZE PACKETS 0 APPLICATION BRIDGING FRAGMENTS 0 JABBERS 0 OPERATION MODE STAND...

Страница 13: ...at is received is the same as the data that was originally sent Alignment errors are due to misaligned packets UNDERSIZE PACKETS Displays the number of packets received whose size was less than the minimum Ethernet frame size of 64 bytes not including preamble OVERSIZE PACKETS Displays the number of packets received whose size exceeded 1518 data bytes not including preamble FRAGMENTS Displays the ...

Страница 14: ... of the following values MMF ST SMF ST PORT STATUS Indicates whether the port has been turned on or off administratively You will see one of the following values ENABLED The port is turned on administratively DISABLED The port is turned off administratively APPLICATION Displays BRIDGING indicating that the port is operating as a bridge with a high speed backbone connection OPERATION MODE Displays ...

Страница 15: ...e the arrow keys to highlight the Port field at the bottom of the screen 2 Press the Space Bar to increment or press the Backspace key to decrement the port number 3 Press the Return key neither the read only Port field nor the statistics will change until you press the Return key Exiting the Port Statistics Screen To exit the Port Statistics screen use the arrow keys to highlight RETURN then pres...

Страница 16: ...re 4 9E428 12 36 and 9E429 12 36 System Resources Screen SmartSwitch 9000 Local Management System Resources Device Name 9E428 36 Firmware Revision 01 00 00 Slot 12 BOOTPROM Revision 01 00 00 CPU Type Intel i960 HX 33Mhz Flash Memory Installed 4 Mb Available XXXXX Bytes DRAM Installed 16 Mb Available XXXXX Bytes SRAM Installed 2 MBytes Available XXXXX Bytes NVRAM Installed XXX KBytes Available XXXX...

Страница 17: ...ze of dynamic random access memory DRAM and indicates how many bytes are currently available SRAM Installed Available Displays the size of static random access memory SRAM and indicates how many bytes are currently available NVRAM Installed Available Displays the size of non volatile random access memory NVRAM and indicates how many bytes are currently available NVRAM is used to store user entered...

Страница 18: ...9E428 12 36 and 9E429 12 36 Module Specific Information 16 ...