background image

 

Specifications

4-4

Содержание 9C214-1

Страница 1: ...SmartSwitch 9000 9C214 1 AC Power Supply Installation Guide 9031156 02...

Страница 2: ......

Страница 3: ...AMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HA...

Страница 4: ...in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible fo...

Страница 5: ...Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above di...

Страница 6: ...Notice iv...

Страница 7: ...ing Up the 9C214 1 Power Supply 2 3 Chapter 3 9C214 1 Power Supply Operation Operating Functions 3 1 System Diagnostic Controller 3 1 Internal Temperature Sensor 3 2 Power Supply Cooling 3 2 LANVIEW L...

Страница 8: ...Contents vi...

Страница 9: ...or unpacking installing and powering up the 9C214 1 power supply Chapter 3 9C214 1 Power Supply Operation contains detailed information regarding the power supply operation Chapter 4 Specifications pr...

Страница 10: ...1 1 The 9C214 1 Power Supply 100 125v 12A 200 250v 6A 50 60 Hz 9C214 1 100 50 0 Load POWER SUPPLY MODULE STATUS P W R S N B Status LED Power Supply SMB Status LED Power Supply Level Indicator LED Powe...

Страница 11: ...in each 9C214 1 power supply This circuit protects the power supply from overheating if a thermal overload occurs Automatic recovery takes place after the thermal overload condition is corrected Load...

Страница 12: ...t variety of power options the 48 volt DC System Power Bus and all components that use this bus are capable of operating using voltage ranging from 40 60 volts DC This capability allows the SmartSwitc...

Страница 13: ...nd revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if know...

Страница 14: ...Introduction 1 6...

Страница 15: ...m the protective plastic bag Save the bag in the event the power supply must be reshipped 3 Examine the power supply carefully checking for damage If any damage exists DO NOT install the power supply...

Страница 16: ...assis remove the power supply realign it and push it in again d Secure the power supply to the chassis by tightening the two screws on the top and two screws on the bottom of the power supply For prop...

Страница 17: ...AC receptacle Turn on the power supply using the switch located near the power socket The power supply uses a soft start feature and does a pre power diagnostic check Outputs become enabled within 5...

Страница 18: ...Installing the 9C214 1 Power Supply 2 4...

Страница 19: ...throughout the chassis for each installed module and the Environmental Module system fans 5 volts supplied to the Diagnostic Power Bus used by the diagnostic controllers and the Environmental Module...

Страница 20: ...emote management Power Supply Cooling Each 9C214 1 power supply includes an internal cooling fan The System Diagnostic Controller monitors the internal temperature of the power supply and increases or...

Страница 21: ...nd 3 3 volt outputs are within established tolerances Yellow Crippled Not fully operational 57 volt output is not within established tolerances due to lack of AC input Red Fault One of the system powe...

Страница 22: ...cription 1 5 Green 10 50 of power load being used No action necessary 6 9 Green 60 90 of power load being used No parallel power supply operational No action necessary 6 9 Yellow 60 90 of power load b...

Страница 23: ...ss A EN 55022 Class A VCCI Class I EMC requirements of EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT Service The 9C214 1 power supply is designed with the following service...

Страница 24: ...5 cubic meters of air per minute drawn through the chassis 76 cubic feet of air per minute drawn through the chassis Universal AC Input Each 9C214 1 power supply accepts input voltage ranging from 100...

Страница 25: ...tor is an IEC type entry requiring the use of the Cabletron approved power cord provided with the 9C214 1 power supply Output Voltage Each 9C214 1 power supply is capable of generating the following o...

Страница 26: ...Specifications 4 4...

Отзывы: