Using LANVIEW
6E123-50 and 6E133-49 User’s Guide
4-3
Table 4-1
LANVIEW LEDs
LED
Color
State
Recommended Action
CPU
Off
Power off.
Power up chassis.
Red
Blinking. Hardware
failure has occurred.
Contact the Cabletron
Systems Global Call Center.
Solid. Resetting,
normal power up reset.
No action.
Amber
Blinking. Crippled.
Contact the Cabletron
Systems Global Call Center.
Solid. Testing.
No action.
Green
Solid. Functional.
No action.
Amber
and
Green
Booting. Blinks amber
and green while
booting.
No action.
Ethernet
Status
(RX) of
ENET1–4
and ports
5 and 6 of
the
6E123-50
Off
No link. No activity.
Port enabled or
disabled.
No error.
Green
Blinking. Port
disabled, link.
No error.
Amber
Flashing. Port
enabled, link, activity.
No error.
Red
Diagnostic failure.
Contact the Cabletron
Systems Global Call Center
for assistance.
Ethernet
Status
(TX) of
ENET1–4
and ports
5 and 6 of
the
6E123-50
Off
Port enabled, and no
activity.
Should flash green every 2
seconds indicating BPDUs
being sent if STA is enabled
and there is a valid link.
Green
Flashing. Indicates
activity. Rate indicates
data rate.
No action.
Amber
Blinking. Port in
standby, link.
Port may be disabled due to
Spanning Tree.
Red
Flashing. Indicates
collision rate.
No action.
Solid. Diagnostic
Failure.
Contact the Cabletron
Systems Global Call Center
for assistance.
Port Link
Status
Green
Solid. Valid link.
No action
Off
No link
Refer to
Section 4.3
.
Содержание 6M146-04
Страница 2: ......
Страница 12: ...Contents x 6E123 50 and 6E133 49 User s Guide ...
Страница 46: ...Chapter 4 Troubleshooting 4 8 6E123 50 and 6E133 49 User s Guide ...
Страница 174: ...Appendix A Specifications A 4 6E123 50 and 6E133 49 User s Guide ...
Страница 178: ...Appendix B FE 100TX FE 100FX and FE 100F3 Specifications B 4 6E123 50 and 6E133 49 User s Guide ...
Страница 186: ...Appendix C Optional Installations and Mode Switch Bank Settings C 8 6E123 50 and 6E133 49 User s Guide ...