background image

ETHERNET

6E233-49

24

48

37

36

25

24

1

12

5

9

6

7

8

10 11 12

1

2

3

4

13 14 15 16

17 18 19 20

21 22 23 24

25 26 27 28

29 30 31 32

33 34 35 36

37 38 39 40

41 42 43 44

45 46 47 48

13

RESET

COM

CPU

Title Page

6E233-49

SmartSwitch 6000 

Interface Module

User’s Guide

9033379

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 6E233-49 SmartSwitch 6000

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU Title Page 6E233 49 SmartSwitch 6000 Interface Module User s Guide 9033379 Artisan Tech...

Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 4: ...S MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Cabletron Systems Inc 35 Industrial Way Rochester N...

Страница 5: ...interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate...

Страница 6: ...t to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in...

Страница 7: ...e with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppl...

Страница 8: ...nt including the U S Department of Commerce which prohibit export or diversion of certain technical products to certain countries unless a license to export the product is obtained from the U S Govern...

Страница 9: ...WARRANTIES OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WI...

Страница 10: ...gram provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of t...

Страница 11: ...ce with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its supp...

Страница 12: ...ormance limitations laser transceiver output meets the Class 1 accessible emission limit of all three standards Class 1 levels of laser radiation are not considered hazardous SAFETY INFORMATION CLASS...

Страница 13: ...quipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above dire...

Страница 14: ...te Monitoring RMON 1 4 1 1 7 Broadcast Suppression 1 4 1 1 8 Port VLAN Redirect Functions 1 5 1 1 9 Rate Limiting 1 5 1 1 10 GARP Switch Operation 1 6 1 1 11 802 1 Port Priority 1 6 1 1 12 Management...

Страница 15: ...4 5 4 3 Using the RESET Button 4 10 A SPECIFICATIONS A 1 Module Specifications A 1 A 2 Physical Properties A 1 A 3 Environmental Requirements A 1 A 4 Input Output Ports A 2 A 5 COM Port Pinout Assignm...

Страница 16: ...3 6 3 3 Connection Using the RJ21 Angle Adapter 3 7 4 1 LANVIEW LEDs 4 2 4 2 RESET Button 4 10 B 1 Module Mode Switch Location Component Layout B 2 B 2 SIMM Slot Locations B 3 B 3 Installing the DRAM...

Страница 17: ...ve and Transmit Status 4 3 4 2 Fault Identification 4 5 4 3 Power System Troubleshooting 4 6 4 4 Firmware Troubleshooting 4 7 4 5 Management System Troubleshooting 4 8 4 6 Device Setup Troubleshooting...

Страница 18: ...IDE Read through this guide completely to understand the 6E233 49 SmartSwitch module s features and capabilities A general working knowledge of IEEE 802 3 type data communications networks and their p...

Страница 19: ...to the 6C105 SmartSwitch 6000 chassis Chapter 3 Installation provides instructions on how to install the module in the chassis and connect segments to the device Chapter 4 Troubleshooting details the...

Страница 20: ...W87 User s Guide HSIM G01 G09 User s Guide VHSIM G6 User s Guide VHSIM A6DP User s Guide WAN Series Local Management User s Guide VHSIM A6DP User s Guide The HSIM W6 Installation Guide the HSIM W84 In...

Страница 21: ...cial importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the equipment Electrical Hazard Warning s...

Страница 22: ...and Asynchronous Transfer Mode ATM The ESX 1620 is not capable of supporting VHSIMs The 6E233 49 SmartSwitch ports can be configured to control frame traffic several ways including prioritizing traff...

Страница 23: ...2 1 2 3 4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU 2693_01 RESET Button CPU LED COM Port Receive RX Transmit TX LEDs...

Страница 24: ...the 6E233 49 SmartSwitch cannot auto negotiate the 6E233 49 SmartSwitch interface operates according to the capabilities of the other device 1 1 3 Runtime IP Address Discovery This feature enables the...

Страница 25: ...or maximum flexibility 1 1 6 Remote Monitoring RMON The 6E233 49 SmartSwitch supports all nine Ethernet RMON groups which include Statistics Alarms Events and History These groups are enabled on all p...

Страница 26: ...or can configure a rate limit from 100 kbps to 1 Gbps for a given port with an associated list of IEEE 802 1p priorities which can include one some or all of the eight priority levels defined in 802 1...

Страница 27: ...tize frames according to protocol type 1 1 12 Management Management of the 6E233 49 SmartSwitch module and 6C105 chassis is accomplished using Local Management application or remote SNMP management st...

Страница 28: ...fully compliant with the IEEE 802 3 802 3x 802 3u 802 1D and especially 802 1Q standards The 6E233 49 SmartSwitch provides IEEE 802 1D Spanning Tree Algorithm STA support to enhance the overall relia...

Страница 29: ...etwork environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any prev...

Страница 30: ...are certain rules concerning port connections and configurations that must be followed for proper operation For more information on SmartTrunk refer to the Cabletron Systems SmartTrunk User s Guide 2...

Страница 31: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 32: ...hillips screwdriver is required to install the HSIMs in the 6E233 49 3 2 UNPACKING THE 6E233 49 SMARTSWITCH 1 Open the box and remove the packing material protecting the module 2 Verify the contents o...

Страница 33: ...d cooling Save the blank plate in the event you need to remove the module 2 Carefully remove the module from the shipping box Save the box and packing materials in the event the module must be reshipp...

Страница 34: ...the module circuit card between the upper and lower metal rail guides of the desired slot sliding it into the chassis and locking down the top and bottom plastic locking tabs as shown in Figure 3 1 Ta...

Страница 35: ...2159 01 Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Backplane Connector ETHERNET 6E233 49 24 48 37 36 25 24 1 12 5 9 6 7 8 10 11 12 1 2 3 4 13 14 15 16 17 18 19 20 21 22 23 24 25 26...

Страница 36: ...Ensure that the device connected to the other end of the segment is powered ON 2 If using an RJ21 straight connector plug it into the appropriate RJ21 port as shown in Figure 3 2 or if using the RJ21...

Страница 37: ...3 2 Straight Cable Connection ETHERNET 6E233 49 24 48 37 36 25 24 1 12 5 9 6 7 8 10 11 12 1 2 3 4 13 RESET COM CPU 2693_07 RJ21 Screw Screw Port 1 LED RX TX 1 Artisan Technology Group Quality Instrume...

Страница 38: ...t the associated port RX LED is on flashing amber blinking green or solid green Figure 3 3 shows the RX and TX LEDs for port 1 If any of the RX LEDs are off perform the following steps to check the as...

Страница 39: ...at steps 1 through 5 until all connections are made 3 6 COMPLETING THE INSTALLATION After installing the SmartSwitch and any optional HSIM and making the connections to the network the SmartSwitch is...

Страница 40: ...on 4 3 4 1 USING LANVIEW The 6E233 49 SmartSwitch uses Cabletron Systems built in visual diagnostic and status monitoring system called LANVIEW The LANVIEW LEDs Figure 4 1 allow quick observation of t...

Страница 41: ...36 25 24 1 12 5 9 6 7 8 10 11 12 1 2 3 4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU 2693_09 CPU LED RX T X 1 Artisan...

Страница 42: ...Contact Cabletron Systems Solid Resetting normal power up reset If the LED remains red for several minutes contact Cabletron Systems Amber Blinking Crippled Contact Cabletron Systems Solid Testing If...

Страница 43: ...ing Port in standby Port may be disabled due to Spanning Tree 1 Ensure that the port is not disabled Refer to the Local Management User s Guide for information on enabling disabling ports 2 Contact Ca...

Страница 44: ...heck connectors for dust or dirt and clean as necessary 2 Power system fault refer to Table 4 3 Module stays in BOOT state 1 Device does not have an operable firmware image and is sending out BootP re...

Страница 45: ...the 6E233 49 SmartSwitch onboard power converter is operational The 6C105 chassis power bus may have a localized fault Install the 6E233 49 SmartSwitch in the working slot and contact Cabletron System...

Страница 46: ...ice has been disabled or the COM port application has been changed 1 Establish a Telnet connection to the device 2 Refer to the Local Management User s Guide on enabling disabling the COM port and cha...

Страница 47: ...y Names Table 1 Refer to the Local Management User s Guide for Community Names Table setup 2 If the Community Names have been forgotten refer to Section B 1 for instructions on clearing NVRAM The 6E23...

Страница 48: ...Reenter the lost parameters as necessary Refer to the Local Management User s Guide for instructions on configuring the device through Local Management 2 Call Cabletron Systems if the problem continu...

Страница 49: ...e reenters the network CAUTION Pressing the RESET button resets the device and all current switching being performed by the module is halted A module downtime of up to two minutes results from this ac...

Страница 50: ...TS Processor Intel i960 RISC processor Power PC Dynamic Random Access Memory DRAM 20 MB expandable to 32 MB FLASH Memory 8 MB Shared Memory 4 MB Dimensions 46 43 H x 6 05 W x 29 51 D cm 18 28 H x 2 38...

Страница 51: ...High Speed Interface Module HSIM Slot accepts optional HSIMs that provide a variety of physical cabling types Table A 1 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Output...

Страница 52: ...ided with 6C105 chassis B 2 SETTING THE MODE SWITCHES These switches are set at the factory and do not need to be changed unless you intend to perform the following Force download a new image file fro...

Страница 53: ...After changing the position of switch 6 and restarting the module the SmartSwitch requests a new image download until they either receive a new image or the RESET button on the front panel is pressed...

Страница 54: ...itch module to expand the DRAM to 32 MB This section explains how to locate and add replace a Single In line Memory Module SIMM For information on the available SIMM upgrades contact Cabletron Systems...

Страница 55: ...e connector teeth 2 Pivot the SIMM downward so the connector clips align with the two side notches of the SIMM and the connector clips lock the SIMM into place Figure B 3 Installing the DRAM CAUTION O...

Страница 56: ...4 shows the location of the connector for an optional High Speed Interface Module HSIM Figure B 4 HSIM Connector Location NOTE NOTE NOTE NOTE Refer to the installation instructions for the optional HS...

Страница 57: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 58: ...RAM installation B 4 M Memory upgrading B 3 P Physical properties A 1 Port Redirect Function introduction to 1 5 R Redirect functions port and VLAN introduction to 1 5 Related documents xvii RESET but...

Страница 59: ...Index 2 T Troubleshooting 4 1 checklist 4 5 U Unpacking 3 1 V VLAN Redirect Function introduction to 1 5 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 60: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: