background image

BLE RS-232 adapter user manual V1.0

2018.05.22

UUID_NOTIFY (~20 bytes)

00031234-0000-1000-8000-00805F9B0130

UUID_RxData (~20 bytes)

00031234-0000-1000-8000-00805F9B0131

UUID_MacID (6 bytes)

00031234-0000-1000-8000-00805F9B0133

UUID_DeviceName (15 bytes)

00031234-0000-1000-8000-00805F9B0134

UUID_Reboot (1 bytes)

00031234-0000-1000-8000-00805F9B0135

UUID_PinID_Setting (6 bytes)

00031234-0000-1000-8000-00805F9B0136

UUID_BLE_CONF (7 bytes)

00031234-0000-1000-8000-00805F9B0132

Byte0

Byte1

Byte2

Byte3

Data bit

Hwfc

Stop Bit

Parity Bit

7,8

0x01:on

0x00:off

2:1

3:1.5

4:2

0x02 : No Parity

0x01 : Odd Parity

0x00 : Even Parity

Byte4

Byte5

Byte6

Baud Rate

Device Mode

Reset To Default

00:9600

01:19200

02:38400

03:57600

04:115200

05:230400

06:2400

07:4800

08:1200

09

460800

10

921600

0x01:on

0x00:off

0x01: Reset

6. Command set via COM port:

Command

Value

Description

AT

Check the connection status between control terminal and the RS-232 
adapter. Response: “OK” when the connection is ok. Response: 
“ERROR” when the connection is not ok.

AT

Test the RS-232 status when first connect the adapter with the 
controller.

(Default)

N

The command will disable the auto link function.

?

Inquire the current setting.

BAUD=

This command is used to specify the baud rate of COM port.
The command will need 200 ms delay.

1200

1200 bps

5

Содержание BLE RS-232 Series

Страница 1: ... 105 g Package Contents BLE RS 232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data transmission Link LED solid on BLE Link Link LED flash No Link Data Link LED solid on DFU OTA Mode DB9 Female Reset to Default 2 dBi Antenna 5 27 VDC GND Mini USB Power LED Link Blue PWR Data Red 1 ...

Страница 2: ...1 Enable 0 1 1 2 00 None 01 Odd 10 Odd 11 Even 0 Slave 1 Master 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 23040 0 Remark 1 000000000 by default in red bold character 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 2 3 DB9 connector Male DCE DTE DIP Switch 2 ...

Страница 3: ... limit 3 2 There re 3 ways to power the adapter Mini USB 2P Terminal Block Blue and pin9 of DB9 please choose one Don t power the adapter by more than one source 3 3 The mini USB to type A cable is inside the standard package 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none Stop bit 1 Flow control none Device Name BLE 232 Pin code 123456 if necessary 4 2 Serial Port Ba...

Страница 4: ...T service and AT command will support all the functions please check the page 4 section 5 and page 5 section 6 4 3 Range max 50 m in open space The range is depend on the real environment 4 4 TX Power Max 3 dBm 4 5 RX Sensitivity 89 dBm typical 4 6 TX current consumption of 15 6 mA radio only 0 dbm 4 7 Operation Temperature 40 C to 70 C 4 8 Dimensions 87 mm L x 34 mm W x 18 mm H 4 9 Antenna Gain m...

Страница 5: ...f 2 1 3 1 5 4 2 0x02 No Parity 0x01 Odd Parity 0x00 Even Parity Byte4 Byte5 Byte6 Baud Rate Device Mode Reset To Default 00 9600 01 19200 02 38400 03 57600 04 115200 05 230400 06 2400 07 4800 08 1200 09 460800 10 921600 0x01 on 0x00 off 0x01 Reset 6 Command set via COM port Command Value Description AT Check the connection status between control terminal and the RS 232 adapter Response OK when the...

Страница 6: ...om the UART are not echoed back to the DTE DCE Default Y Command characters received from the UART are echoed back to the DTE DCE Inquire the current setting FLOW This command enable or disable flow control signals CTS RTS of the UART port Note the setting is not affected by DEFAULT The command will need 1 second delay Default N Disable flow control Y Enable flow control Inquire the current settin...

Страница 7: ...e current role of the adaptor STATUS Inquire all the current setting of the adapter T Inquire the inner temperature of the IC in centigrade Display the current setting of the adapter STOP This command is used to specify one or two stop bits of COM port The command will need 200ms delay Default 1 One stop bit 2 Two stop bits Inquire the current setting VERSION This command is used to inquiry the fi...

Страница 8: ...other one as the peripheral and link The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripheral on next time when power on Please reset to the default and follow the above procedures if you want to link with other BLE devices 8 APP The APP is used for the configuration and the data transmission test Scan and se...

Страница 9: ...BLE RS 232 adapter user manual V1 0 2018 05 22 9 ...

Отзывы: