Operation    

 

Switch   On   -­‐   With   the   UPS   plugged   in,   press   the   power   switch   in   to   switch   

the   UPS   on.   The   UPS   will   perform   a   self-­‐test   each   time   it   is   switched   

on   and   the   buzzer   will   beep   2   times.   

 

Switch    Off    -­‐    By    depressing    the    power    switch.    UPS    will    keep    charging   

batteries.   

 

Backup    (Beeping    1    time    every    5    seconds)    -­‐    When    in    Backup    mode,    the   

battery    illuminates    and    the    UPS    emits    a    beeping    sound    every    four   

seconds.    Press    the    power    switch    to    stop    the    beeping.    The    alarm   

stops   when   the   UPS   returns   to   normal   utility   mode   of   operation   

 

Low    Battery    (Beeping    2    times    every    1    second)    -­‐    In    Backup    mode,    when   

the    battery    energy    runs    low,    the    UPS    beeps    rapidly    until    the    UPS   

shuts   down   due   to   complete   battery   discharge.   

 

Overload   (Beeping   4   times   every   2   seconds)   -­‐   When   the   UPS   is   overloaded   

all    three    LED’s    turn    on    and    the    buzzer    beeps    every    1    second.   

Promptly   disconnect   non-­‐essential   load   equipment   from   the   UPS   to   

eliminate    the    overload,    otherwise,    the    UPS    will    shut    off    output   

power.    The    time    for    shut-­‐down    is    determined    by    the    size    of    the   

overload   

 

NOTE:        If    the    UPS    is    working    in    battery    mode,    DO    NOT    turn    on    any   

additional   loads   such   as   a   computer   or   monitor   or   return   any   loads   

from   sleep   mode,   otherwise,   the   UPS   may   operate   its   overload   or   

short   circuit   protection.   

 

   

Содержание UPS600DV3

Страница 1: ...les cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 1 Version 1 CABAC UNINTERRUPTIBLE POWER...

Страница 2: ...co nz W cabac co nz 2 2 of 21 Contents General Safety Instructions 3 Conditions of Use 3 Electrical Safety 4 Safe Operating Practices 5 Battery Information 7 Introduction 8 Performance 8 Installation...

Страница 3: ...in hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent Conditions of Use This equipment is de...

Страница 4: ...e UPS cover It may contain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Cabac UP...

Страница 5: ...nication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries an...

Страница 6: ...P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 6 6 of 21 disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plu...

Страница 7: ...o the skin and eyes 3 A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other...

Страница 8: ...r is used as the main controller that renders the product an intelligent UPS capable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power sup...

Страница 9: ...ction When the UPS is turned ON it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves...

Страница 10: ...temperature and humidity is outside the specified limits in the Specifications Table 3 Connect to Mains Power Connect the AC input power cord to a socket outlet to power up the UPS The battery in the...

Страница 11: ...cabac co nz W cabac co nz 11 11 of 21 Physical Appearance Front Panel Rear Panel Item Description 1 On Off Power Switch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 R...

Страница 12: ...dicators Front Panel Indicator Buzzer Status Operational Description LED 1 Green LED2 Yellow LED 3 Red OFF ON OFF OFF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON...

Страница 13: ...s the power switch to stop the beeping The alarm stops when the UPS returns to normal utility mode of operation Low Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs l...

Страница 14: ...750W Input Characteristics Rated Input Voltage 230 240V Input Voltage Range 165 275 V Rated Input Frequency 50 Hz 10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Outpu...

Страница 15: ...mm x 124mm x 382mm Operating Temperature 10 C to 40 C Maximum Operating Relative Humidity 95 Relative Maintenance 1 With normal use a UPS battery will last 2 to 3 years depending on the number of disc...

Страница 16: ...es cabac co nz W cabac co nz 16 16 of 21 Software Installation In order to utilise the UPS to its full potential the monitoring software must first be installed Please install the software according t...

Страница 17: ...stribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 17 17 of 21 3 Enter details as requested on this screen Your product serial n...

Страница 18: ...sales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 18 18 of 21 5 Select language English...

Страница 19: ...8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 19 19 of 21 7 Installation is now complete Click FINISH 8 The program is...

Страница 20: ...No LED s on i Battery Discharged Sleep Mode Press the POWER button ON ii PCB failure Contact Service Agent UPS always at battery mode Power cord lose Re plug the power cord Line voltage too high too l...

Отзывы: