WARNING  

To reduce the risk of fire or electric shock, do not expose this product to rain or 

moisture. The meter is intended only for indoor use. 

 

To avoid electrical shock hazard, observe the proper safety precautions when working 

with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a potential 

shock hazard to the user.   

 

Inspect test leads, connectors, and probes for damaged insulation or exposed metal 

before using the instrument. If any defects are found, replace them immediately.   

 

Do not touch test lead tips or the circuit being tested while power is applied to the 

circuit being measured. To avoid accidentally short circuit of bare (uninsulated) 

hazardous live conductors or busbars, switch them off before insertion and removal of 

the current clamp jaws. Contact with the conductor could result in electric shock. Keep 

your hands/fingers behind the hand/finger barriers that indicate the limits of safe 

access of the meter and the test leads during measurement.   

 

CAUTION 

Disconnect the test leads from the test points before changing meter functions.   

 

INTERNATIONAL ELECTRICAL SYMBOLS 

 

!

 

Caution !    Refer to the explanation in this Manual 

   

Caution !    Risk of electric shock 

   

Earth (Ground) 

   

Double Insulation or Reinforced insulation 

 

 Fuse 

 

 

AC--Alternating Current 

 

 

DC--Direct Current 

 

2) CENELEC Directives 

The instruments conform to CENELEC Low-voltage directive 73/23/EEC and 

Electromagnetic compatibility directive 89/336/EEC 

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au 

A: Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

2

Содержание BM117

Страница 1: ...TM Clamp on Multimeter Series Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz ...

Страница 2: ...ry appliances OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation Note Examples include electricity ...

Страница 3: ...fore insertion and removal of the current clamp jaws Contact with the conductor could result in electric shock Keep your hands fingers behind the hand finger barriers that indicate the limits of safe access of the meter and the test leads during measurement CAUTION Disconnect the test leads from the test points before changing meter functions INTERNATIONAL ELECTRICAL SYMBOLS Caution Refer to the e...

Страница 4: ...ions EXCEPT non invasive ACA current function 6 Common Ground reference Input Jack for all functions EXCEPT non invasive ACA current function 7 Slide switch Selector to turn the power ON OFF and Select a function 8 3 5 6 digits 6000 counts LCD display 9 Jaw trigger for opening the transformer clamp jaws 10 Jaw center Indicators at where best ACA accuracy is specified 11 Transformer Clamp Jaws for ...

Страница 5: ...will introduce measurement errors Enclosing more than one conductor of a circuit will result in differential current like identifying leakage current measurement Adjacent current carrying devices such as transformers motors and conductor wires will affect measurement accuracy Keep the jaws away from them as much as possible to minimize influence Customer Care Australia P 13122 F 1300 303 310 E sal...

Страница 6: ...z is selected AC 6V range has the highest and AC 600V range has the lowest sensitivity Measuring the signal in ACV function WHILE selecting Line Level Hz function in that ACV range automatically sets the most appropriate sensitivity for higher voltage applications This can avoid electrical noises as in 110 220V line voltage applications for example If the reading shows zero due to insufficient sig...

Страница 7: ...signal above the threshold of 1 5 VDC 1 VDC or 2 VAC up to the rated 600V is present the meter displays the voltage value in appropriate DC or AC whichever larger in peak magnitude Overload Alert Feature When above rated 600V is present the meter displays OL with a warning beep tone for over range indication Disconnect the test leads from the signal immediately to avoid hazards Note Range Lock Fea...

Страница 8: ...s on high voltage hard signals LoZ displays on the LCD to remind the users of being in such low impedance mode Peak initial load current while probing directly to 600VAC for example can be up to 530mA 600V x 1 414 1 6kΩ decreasing abruptly to approx 4mA 600V x 1 414 210kΩ within a fraction of a second Do not use AutoCheckTM mode on circuits that could be damaged by such low input impedance Instead...

Страница 9: ...cts electric field surrounds current carrying conductors It is ideal for tracing live wiring connections locating wiring breakage and to distinguish between live or earth connections Probe Contact EF Detection For more precise indication of live wires such as distinguishing between live and ground connections use the Red test probe for direct contact measurements Customer Care Australia P 13122 F ...

Страница 10: ...y selects Diode test function The reading shows the approximate voltage drop across the test leads When forward biased normal forward voltage drop for a good silicon diode is between 0 400V to 0 900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective and the meter gives a continuous beep warning An OL indicates an open diode defective Re...

Страница 11: ...o avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case Trouble Shooting If the instrument fails to operate check batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual If the instrument voltage resistance ...

Страница 12: ...placement The meter uses standard 1 5V AAA Size NEDA 24A or IEC LR03 battery X 2 Loosen the 2 captive screws from the battery cover case Lift the battery cover case Replace the batteries Replace battery cover case Re fasten the screws Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 0800 966 969 F ...

Страница 13: ...tion repair or replace the defective product free of charge However if BRYMEN determines that the failure was caused by misused altered neglected or damaged by accident or abnormal conditions of operation or handling you will be billed for the repair THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTA...