1 Introduction

1.3 

Protective Devices

!

Warning!

There is a risk of injury if protective devices are missing or defective. 

 

Replace all protective devices (covers, safety notices, grounding cables etc) after maintenance work 
has been completed. 

 

Replace parts that have become defective or unusable. 

Wear protective goggles for: 

• 

Knocking pins or similar parts in or out with a hammer. 

• 

Using spring hooks. 

• 

Inserting or removing springs, retaining rings or grip rings. 

• 

Using solvents, cleansers or other chemicals.

1.4 

Handling Electricity 

The following work may only be done by trained and qualified electricians: 

• 

Work on electrical components. 

• 

Work on an open device still connected to the mains supply. 

General precautions before starting maintenance work: 

• 

Find out where the emergency and power switches are so that they can be quickly thrown in an emergency. 

• 

Disconnect the current supply before carrying out the following work: 

 

- Installing or removing power units. 

 

- Working in the immediate vicinity of open power supply components. 

 

- Mechanical check of power supply components. 

 

- Modifying circuits in the device. 

• 

Test the zero potential of the device parts. 

• 

Check the working area for possible sources of danger, such as wet floors, defective extension cables, defective 

protective conductor connections. 

Additional precautions in the case of exposed voltages: 

• 

Ask a second person to remain near the working site. This person must know where the emergency and power 

switches are, and how to switch the current off if danger arises.

• 

Only use one hand to work on electric circuits of devices that are switched on. Keep the other hand behind your 
back or in your pocket. 

This prevents electricity from flowing through your own body.

1.5 

Procedure in Case of Accidents 

• 

Act calmly and with great care.

• 

Avoid danger to yourself.

• 

Switch off power.

• 

Request medical assistance.

• 

Give first aid, if necessary.

1.6 

Environment



Obsolete assemblies contain valuable recyclable materials that should be sent for recycling.

 

Send to suitable collection points, separately from residual waste.

 

Send the parts for recycling.

Содержание WICON SQUIX

Страница 1: ...Service Manual MADE IN GERMANY WICON Wrap around applicator...

Страница 2: ...products discrepancies between documentation and product can occur Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General condit...

Страница 3: ...3 1 Removing the Side Covers 7 2 3 2 Removing the Service Door 7 3 Replacing Assembly Units 8 3 1 Replacing the Transport Module 8 3 2 Replacing the PCB Sensor Labels 8 3 3 Replacing the Centering Pan...

Страница 4: ...nt Handling instruction Reference to section position illustration number or document Option accessories peripheral equipment special fittings Time Information in the display 1 2 General Safety Instru...

Страница 5: ...ng power units Working in the immediate vicinity of open power supply components Mechanical check of power supply components Modifying circuits in the device Test the zero potential of the device part...

Страница 6: ...wrench 9 Allen key 2 mm Allen key 2 5 mm Open end wrench 5 Snap ring pliers ZGG 0 Pointed pliers straight Belt tension measuring device cab special tools Calibration rod 10 mm Part No 5988543 2 2 Remo...

Страница 7: ...1 and remove the side covers 2 3 Re mounting will be carried out in opposite order 2 3 2 Removing the Service Door i Note It is not absolutely necessary the remove the service door But with the side c...

Страница 8: ...le 6 The screw 2 is secured and remains in the winding plate X Guide the pins 4 of the new transport module into the holes 1 and fix the transport module by tightening the screw 2 X Mount the covers 3...

Страница 9: ...nder side 3 2 1 4 2 1 5 3 2 1 5 4 2 1 Fig 6 Replacing the centering panels X Remove the covers X Loosen two screws 1 and washers 2 and remove the centering panel 3 X Disconnect the cable 5 from the PC...

Страница 10: ...Tighten the shoulder screws i Note The applicator must be operated with the printer to adjust the shoulder screws Caution Risk of hand injuries X Do not grasp in the area of the turning winder plate X...

Страница 11: ...1 7 5 8 Fig 10 Tensioning the belt X Check the tension of the belt Pluck the belt at the marked point 1 and measure the frequency of the oscillation withe a belt tension measuring device Set value f...

Страница 12: ...e cam plate 3 and the transport module 6 out of the housing X Pull the cam plate 3 from the pins 5 X Set the new cam plate onto the pins 5 9 10 Fig 12 Replacing the locking lever X Pull the locking le...

Страница 13: ...9 8 7 4 5 6 3 13 12 11 Fig 14 PCB Control connectors Pos Connector Lettering 3 Periphery Periphery 4 LP Sensor Centering gear side Centering L 5 LP Sensors Reference Diameter Ref Dia 6 LP Spring Cont...

Страница 14: ...le step key and observe the hunting of the rod If the rod hunting seems to be excessive the centering panels 7 may be adjusted individually 1 2 3 2 Fig 15 Adjusting the centering panels Adjusting X Re...

Страница 15: ...art No 5988543 X Select Continue The wrapping unit will be turned ten times with closing and opening the jaws and measuring the diameter of the test pipe X The display shows the success of the calibra...

Страница 16: ...and the software Transport module defective X Replace the transport module PCB Spring Contact soiled X Clean the contacts PCB Spring Contact defective X Replace the PCB Spring Contact Contacts at the...

Страница 17: ...ing L 5907839 PCB Sensors Ref Diam 5555155 Periphery 5555157 PCB Touchgard Sensor 5555156 Service Button Sensor Applicator locked Fan Motor Guard Motor Winder PCB Spring Contacts PCB Sensor Labels Mot...

Страница 18: ...ls Adjusting 14 Replacing 9 Covers 7 D Diameter recognition 15 E Error treatment 16 G Guard Plate 10 I Important information 4 L Locking lever 12 P PCB Control 13 PCB Sensor Labels 8 S Safety instruct...

Отзывы: