6.14.3 Removing the pliers assembly
To change the cylinder lug or the connecting rod linkage, the pliers assembly (5) must be dismounted.
4
5
1
2
3
Fig. 38
Dismounting the pliers assembly
First pull all tubes (2/3) coming from the valve block out of the connectors.
These are provided with number markers and can be reassigned based on the instructions for the throttle valves
of the cylinders and the pneumatic plan after reassembly.
Loosen the setscrews on the sensors of the cylinder 'peel position', 'flag' and 'pliers' and pull out the sensors (2/3)
on the cylinders.
Secure the pliers assembly (5) against falling and loosen the screws (4) on the plate (1).
Remove pliers assembly (5) and disassemble into the following assemblies / parts.