20
20
6
Adjustments
6.1
Compressed Air Connection
!
Attention!
Adjustments and functionality control were done with a compressed air value of 4.5 bar.
The applicator's operating range is between 4.0 and 6.0 bar.
!
Warning!
When connecting the applicator to compressed air it is considered "IN USE!" Cylinder motion is possible!
Do not reach into the zone of the moving pad and keep long hair, loose clothes, and jewelry away.
2
1
3
1. Check that the stop valve (2) is closed as
illustrated.
2. Attach compressed air to connector (1).
3. Open the stop valve (2) by turning it into the
direction of air flow.
4. Switch on the printer via the power switch.
A pressure regulation unit (3) must be connected
upstream to stabilize the compressed air supply.
Fig. 14
Compressed air connection
i
Note!
If the pad is not in the starting position when the printer is switched on an error message will appear on the
display.
Press the continue button on the printer to cancel the error state. The applicator will move into the start
position and is ready for work.
i
Note!
Only mount the air pressure regulation unit as illustrated otherwise the functionality of the air-water
separator cannot be guaranteed.