34
34
6.14
Set Cylinder Flag / Actor 2
6.14.1
Set Cylinder 'flag' throttle valves
2.03
2.04
Z
X
Y
Throttle valve (2.04) movement inside
Marker on the tube with the number 3
Close the throttle valve (2.04) completely.
Turn the set screw clockwise until it stops.
If no different value is noted in the test report,
open the throttle valve (1.01) by turning it
8 turns
counterclockwise.
Throttle valve (2.03) movement outside
Marker on the tube with the number 4
Close the throttle valve (2.03) completely.
Turn the set screw clockwise until it stops.
If no different value is noted in the test report,
open the throttle valve (2.03) by turning it
9 turns
counterclockwise.
Fig. 36
Cylinder 'flag' throttle valves
6.14.2
Set Cylinder 'flag' sensors
1
2.01
8 mm
8 mm
3
2.01
Sensor (2.01) Pads in start position
Marker on the sensor with the number 3
If no different value is noted in the test report,
set the distance between the edge of the sensor (2.01) and the
edge of the connection ring (1) to 8 mm.
As a check, switch on the printer and switch on compressed air.
In the start position of the applicator, the LED on the sensor must
light up. The lifting cylinder is completely retracted in this position.
Sensor (2.02) Pads are closed
Marker on the sensor with the number 4
If no different value is noted in the test report,
set the distance between the edge of the sensor (2.02) and the
edge of the connection ring (3) to 8 mm.
As a check, switch on the printer and the LED on the sensor does
not light up. The LED lights up when the pair of pads is closed.