25
6.4.3
Moving the Pad in X-Direction
y
x
z
y
x
z
1
2
3
4
5
6
7
Fig. 20
Displacement in the Y direction
Displacement in the X direction (Side)
1. Loosen screw (3) on the binder (5).
2. Move cylinder assembly with the pad along the crossbeam (4) so that the dispensed label (7) is aligned centrally
to the pad (6). As reference use the provided graduation/ruler on the crossbeam.
Orientation: Graduation (2) and Marking (1)
3. Tighten screw (3).
text side 1
text side 2
L
L
D
(Ø) x
Pi
(
)
D
L
V
P
Fig. 21
Label parameter
A misalignment of the pad to the printer can be recognized by the increase in the length offset P
and / or the bevel V (side offset)
-
With bevel V (side offset) the parallelism of the pad to the dispensing edge of the printer must be set.
-
With length offset P, the position of the punch in the X direction must be set.