Copyright © 2006-2014 Shenzhen C2S Technology Co., Ltd. All rights reserved.
2. Knowledge before Usage:
2.1Factory Default Setting
-
IP/Port: Empty
-
APN, User and pass: Empty
-
Speed Limit: Off=000Km/H
-
Position data Update Time Interval: 60Minutes
-
Authorized Phone numbers A/B/C: None
-
Device SMS password: 1234
2.2 Power Supply and consumption
This device is expected to connect with a DC power source with range of 11.2-36V DC.
Working current maximum 2A input.
In standby mode, device working current < 40mA @12V DC
In sleep mode, working current is less than 6mA @12V DC.
2.3 How to Insert Simcard
N/A
2.4 Device configuration
TR-11E allow user to use SMS Commands to configure necessary parameters.
Details please check as follows instruction:
-
Configure GPRS Parameter
SMS Command:
*1234*GPRS:211.154.142.150,9114,T,apnName,apnUser,apnPass
#
T
is data transmit mode. T=1 is using UDP mode. T=0, is using TCP mode. Default as
0.
-
Device ID
TR-11E doesn’t need configure device ID. The device is default using Device SN
code as ID.
On the unit case side is with a barcode sticker. please use this code as device ID when
you register device tracking platform.
-
Configure Authorized Phone Numbers for alarm alerts:
SMS command:
*1234*A8613554806820*B13554806821*C13554806822#