Wiring Requirements
Network Requirements
S. no.
S-001
CU board Power
18-22
Recommended
S-002
Lock Power
18-22
Recommended
S-003
ACM4/PD4UL/PD8UL
18-22
Recommended
S-004
Door position sensor
24
Yes
S-005
Request to Exit
24
Yes
S-006a
Weigand Card Reader
18
Yes
S-006b
Weigand Card Reader
22
Yes
S-007
Firelarm input
24
Yes
S-008
RJ-45 Ethernet Cable
n/a
Cat5/5e
Yes
Signal
Belden Wire part no.
AWG (max - min)
Shielded?
Remarks
Can use multi pair
conductors to reduce
individual wires
API Endpoints
Swiftlane Door Controller Panel Firewall Configuration
Enable bidirectional connections for port 80 and 443
Enable bidirectional
(for communication between API and door
controller hardware)
Enable bidirectional
(for communication between API and door
controller hardware)
Customers should allow complete outbound connections from Access Point devices on port 80 and
443. This ensures the highest level of reliability for the system.
However, here are some specific endpoints called from the Swiftlane system. Please note that this is a
changing set of requirements and may affect future performance of the device. We highly recommend
that you allow all outgoing 80/443 traffic from the Swiftlane devices.
admin.swiftlane.com/*
[swiftpass.ue.r.appspot.com/](<https://swiftpass.ue.r.appspot.com/>)*