URRS control panel terminal block
Connection details between C Systems URRS control panel and
transducers. Fig A & B shows the possible wiring methods
between transducers and Panel.
The maximum distance from the panel to last transducer shall
be 130m in case of looping is desired (Fig-B)
Procedure for URRS installation at site
Select a proper location near the electrical power socket
of about 5 A AC. Fix the panel with the help of key holes
provided at the back of the panel. No brackets and
accessories are required for mounting.
Proper earthing has to be done in the AC socket to
avoid unnecessary leakage current. Also check of
proper voltage at AC socket
Each transducer covers an area of respective Sq ft as per
models.
The transducer consists of 2 parts, top cover and bottom
lid. Use a ¾ inch or 1 inch electrical junction box to mount
the bottom lid. The holes in dummy plate in junction box
exactly suit the holes in the bottom lid.
After termination, press the top cover over the bottom
lid. Press and lock type.
Each transducer can be connected to the controller via
separate cable or by connecting the transducers in
parallel.
Cables shall be either in GI or PVC conduit.