Thumb Set
The THUMB SET control is located at the tip of the handle. When using the CS9000 MK2
without the AUTO feature, the control may be pressed to the momentary position quickly with
the loop over a target reducing the intensity of the signal making it easier to pinpoint. Further
discussion of the use of the THUMB SET control is found in the OPERATION section.
FEATURES
Automatic Threshold
The Automatic Threshold feature is a ‘self-adjusting threshold’, this is often referred to as
“motion” mode, this feature maintains a smooth operating threshold, or background ‘hum’ while
the detector is operated. This hum may drift up or down because of ground mineralisation
changes that are present from one place to another during searching. Even though large changes
in ground mineralisation will still require adjustment of the Ground Balance control, the smaller
variations can be overcome with the Automatic Threshold feature. If the sound is permitted to
drift too far from the proper setting, the depth performance of the instrument will decrease
somewhat leaving some targets undetected. To activate the Automatic Threshold feature, simply
move the switch to the AUTO.
Ground balance
A unique feature of the CS9000 MK2 is its’ ability to cancel the effects of ground mineralisation.
This allows the detection of objects that would otherwise not be able to be detected because of
the presence of mineral in the soil. While not all sites are affected by this phenomena, many will
find this a very useful feature because of its’ increased depth of detection in very difficult soil.
CS9000 MK2 OPERATION
Ground balancing Metal Mode
1.
Set the THRESHOLD, SIGNAL BALANCE, and GROUND BALANCE control knobs to
the centre of the NORMAL range. Set the AUTOMATIC THRESHOLD control to AUTO.
2.
Turn the MODE control to the BATT. CHK position and check the meter to determine the
condition of the battery paCHK Then turn the MODE switch to the METAL position. The
CS9000 MK2 will operate with these settings in the NORMAL range in most locations.
However, if further adjustment is needed for ground mineralisation proceed as follows: -
Ground balance Procedure
i.
Set the AUTOMATIC THRESHOLD switch to the OFF. Make sure that the detector is
well away from all large metal objects such as cars, pipes, rebar, etc.