6 Binding with the CP
«Binding» mode is used for logging the Detector in the CP and service
information exchange.
6.1 Prepare the CP in accordance with CP Installation Guide.
6.2 If it is necessary to log the Detector in double-channel mode,
switch TS to the Detector as shown in Figure 3 or short-circuit the
terminals of the Detector «minus» and «Channel 2». For the single-
channel mode neither switching on, no short-circuit is required.
6.3 Set the backup power supply battery to the holder plate on the
PCB other side.
6.4 Set the main power supply battery to the holder plate (6).
6.5 Periodical LED indicator blinking green is evidence of binding
process.
6.6 In case of mentioned above LED indication absence, short-circuit
«
RESET
» terminals for 2 – 3 sec.
6.7 Successful binding procedure complying is indicated by LED
indicator lighting red for 2 – 3 sec.
6.8 The time limit for the binding process of the Detector is 100 sec.
To restart the binding procedure, short-circuit
«
RESET
» terminals for
2 – 3 sec.
7
«Stand Alone» mode
7.1 The Detector changes to standalone mode upon the expiry of
100 sec binding procedure.
7.2 During operation in the standalone mode the Detector has no
communication with CP and it’s state is displayed only by means of
LED and sound indication (see Table 3).
7.3 During operation in the standalone mode LED and sound indication
is always ON under condition of
«Tamper»
message absence.
7.4 During operation in the standalone mode the detector operates
within the last temperature range limits adjusted.
8 Communication Quality Appraising
8.1 For radio communication quality appraisal it is necessary to:
- place firstly backup and then main power supply batteries to the
correspondent holder plates;
- set the Detector on the assumed place of installation;
- push and then release case tamper.
8.2 After case tamper releasing the Detector generates case
tamper alarm message, transmits it via radio communication channel and
represents communication quality with CP by LED indication in
accordance with the Table 4.
Table 4
LED Indication
Radio
communication
quality appraisal
Recommendations
Color
Mode
Green
Three blinks
Excellent
Install the Detector on
this place
Green
Two blinks
Good
Green
One blink
Communication
established
Choose another place
for installation or use a
repeater*)
Red
Four blinks
No
communication
*)
–
«CN-Repeater»
9 Installing the Detector
Open the Detector cover and remove the PCB. The cover is fixed on
the base by means of latches.
For PCB removal push up the trip (7) (See
Figure
1) on the base.
Prepare the fixation holes. For the holes layout mark, the base of the
Detector can be used (See
Figure 2).
Fasten the base by means of screws. For the wall tamper control
screw the second screw to the wall tamper clip.
Install the PCB and if it is necessary, hook up TS to the terminals in
accordance with
Figure
3. Put the cover on it’s place.
Rev. 0 of 30.10.15
№00173
10 Storage and Transportation
10.1 Factory-packed detectors can be shipped by any transport
means in covered vehicles (in railway, cars, trucks, sealed heated
compartments of aircraft, ship cargo holds etc). The Detector is
resistant to:
а) transport jolting with the acceleration of 30 m/sec
2
with impact
frequency rate from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
b) the ambient temperature
minus
50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.
10.2 After transportation under the conditions different to exploitation
conditions the detector shall be ready to operate after a maximum of
six hours.
10.3 The storage room shall be free from current-conducting dust,
acid vapors, alkali and gases that cause corrosion and destroy insulation.
11 Manufacturer’s Guarantees
11.1 «
RIELTA
»
JSC guarantees conformity of the Detector to it’s
Technical Specifications if conditions of transportation, storage, assembling
and operation are observed. The guaranteed storage period is 63 months
since the date of manufacturing the Detector.
11.2 The guaranteed period of operation is 60 months since the date
of commissioning within the storage period guaranteed.
11.3 For guaranteed maintenance, please contact:
«С.Nord»
STCF
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC
«
Obvodny Dvor
»
Phone: (812) 327-16-36
E-mail: [email protected], [email protected], www.cnord.ru
Note
–
The guaranteed period for the Detectors isn’t applied to the
power supply batteries.
12 Packing Certificate
Wireless temperature detector «CN-Celsius» manufactured in
accordance with current technical documentation is classified as fit for
operation and is packed by
«
RIELTA
»
JSC.
Person responsible for acceptance and packing
QC representative_________________ __________________.
Date, month, year
Fixation Holes
Figure 2 – The Detector Base
Figure 3 –
The TS Hooking up
to the Detector
TS
+3,3V- 2 Channel 1
The Detector
Red
Black
Yellow
Wall
Tamper
Clip
By order of
«С.Nord»
STCF, www.cnord.ru
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC
«
Obvodny Dvor
»,
Phone: (812) 327-16-36, [email protected]
Technical support: [email protected], http://support.cnord.ru
Made in Russia
The Manufacturer:
«
RIELTA
»
JSC, www.rielta.com
Russia, 197101, St. Petersburg, Chapaeva str., 17
Phone /fax: +7 (812) 233-03-02, 703-13-60, [email protected]
Technical support: phone +7 (812) 233-29-53, 703-13-57, [email protected]