background image

6 Binding with the CP

 

«Binding» mode is used for logging the Detector in the CP and service 

information exchange.

6.1 Prepare the CP in accordance with CP Installation Guide.
6.2 If it is necessary to log the Detector in double-channel mode, 

switch  TS  to  the  Detector  as  shown  in  Figure  3  or  short-circuit  the 

terminals of the Detector «minus» and «Channel 2». For the single-

channel mode neither switching on, no short-circuit is required.

6.3 Set the backup power supply battery to the holder plate on the 

PCB other side. 

6.4 Set the main power supply battery to the holder plate (6).
6.5  Periodical  LED  indicator  blinking  green  is  evidence  of  binding 

process.

6.6 In case of mentioned above LED indication absence, short-circuit 

«

RESET

» terminals for 2 – 3 sec.

6.7  Successful  binding  procedure  complying  is  indicated  by  LED 

indicator lighting red for 2 – 3 sec.

6.8 The time limit for the binding process of the Detector is 100 sec. 

To restart the binding procedure, short-circuit 

«

RESET

» terminals for 

2 – 3 sec.

«Stand Alone» mode

7.1 The Detector changes to standalone mode upon the expiry of 

100 sec binding procedure.

7.2 During operation in the standalone mode the Detector has no 

communication with CP and it’s state is displayed only by means of 
LED and sound indication (see Table 3).

7.3 During operation in the standalone mode LED and sound indication 

is always ON under condition of 

«Tamper»

 message absence.

7.4 During operation in the standalone mode the detector operates 

within the last temperature range limits adjusted.

8 Communication Quality Appraising

8.1 For radio communication quality appraisal it is necessary to:
- place firstly backup and then main power supply batteries to the 

correspondent holder plates;

- set the Detector on the assumed place of installation;

- push and then release case tamper.
8.2 After case tamper releasing the Detector generates case  

tamper alarm message, transmits it via radio communication channel and  

represents  communication  quality  with  CP  by  LED  indication  in 
accordance with the Table 4.

Table 4

LED Indication

Radio 

communication 

quality appraisal

Recommendations

Color

Mode

Green

Three blinks

Excellent

Install the Detector on 

this place

Green

Two blinks

Good

Green

One blink

Communication 

established

Choose another place 

for installation or use a 

repeater*)

Red

Four blinks

No 

communication

*) 

 «CN-Repeater»

9 Installing the Detector

Open the Detector cover and remove the PCB. The cover is fixed on 

the base by means of latches.

For PCB removal push up the trip (7) (See 

Figure 

1) on the base.

Prepare the fixation holes. For the holes layout mark, the base of the 

Detector can be used (See 

Figure 2).

Fasten the base by means of screws. For the wall tamper control 

screw the second screw to the wall tamper clip.

Install the PCB and if it is necessary, hook up TS to the terminals in 

accordance with 

Figure 

3. Put the cover on it’s place.

Rev. 0 of 30.10.15

№00173

10 Storage and Transportation 

10.1  Factory-packed  detectors  can  be  shipped  by  any  transport 

means  in  covered  vehicles  (in  railway,  cars,  trucks,  sealed  heated 

compartments of aircraft, ship cargo holds etc). The Detector is 

resistant to:

а) transport jolting with the acceleration of 30 m/sec

2

 with impact 

frequency rate from 10 to 120 impacts/sec or 15000 impacts with the 
same acceleration;

b) the ambient temperature 

minus 

50 … +50 °С;

c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.

10.2 After transportation under the conditions different to exploitation 

conditions the detector shall be ready to operate after a maximum of 

six hours.

10.3 The storage room shall be free from current-conducting dust, 

acid vapors, alkali and gases that cause corrosion and destroy insulation.

11 Manufacturer’s Guarantees

11.1  «

RIELTA

»

  JSC  guarantees  conformity  of  the  Detector  to  it’s 

Technical Specifications if conditions of transportation, storage, assembling 
and operation are observed. The guaranteed storage period is 63 months 

since the date of manufacturing the Detector. 

11.2 The guaranteed period of operation is 60 months since the date 

of commissioning within the storage period guaranteed.

11.3 For guaranteed maintenance, please contact:

«С.Nord»

 STCF

Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC 

«

Obvodny Dvor

» 

Phone: (812) 327-16-36
E-mail: [email protected], [email protected], www.cnord.ru

Note

 –

 The guaranteed period for the Detectors isn’t applied to the 

power supply batteries.

12 Packing Certificate 

Wireless temperature detector «CN-Celsius» manufactured in 

accordance with current technical documentation is classified as fit for 
operation and is packed by 

«

RIELTA

»

 JSC.

Person responsible for acceptance and packing 

QC representative_________________    __________________.

                                                           

 Date, month, year

Fixation Holes

Figure 2 – The Detector Base 

Figure 3 – 

The TS Hooking up

 to the Detector

TS

+3,3V- 2 Channel 1

The Detector

Red

Black

Yellow

Wall 

Tamper 

Clip

By order of 

«С.Nord»

 STCF, www.cnord.ru

Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC 

«

Obvodny Dvor

»,

Phone: (812) 327-16-36, [email protected]
Technical support: [email protected], http://support.cnord.ru

Made in Russia  

The Manufacturer: 

«

RIELTA

»

 JSC, www.rielta.com

Russia, 197101, St. Petersburg, Chapaeva str., 17
Phone /fax: +7 (812) 233-03-02, 703-13-60, [email protected]
Technical support: phone +7 (812) 233-29-53, 703-13-57, [email protected]

Отзывы: