background image

WIRELESS TEMPERATURE

DETECTOR

«CN-Celsius»

Installation Guide

1 General information

1.1 Wireless temperature detector «CN-Celsius» (hereinafter, 

«the Detector») is designed for the temperature measurement and 

it’s  control  within  the  preset  range  and  out-of-range  temperature 
messages sending via wireless two-way communication channel within 

 

433.05 – 434.79 MHz frequency range by the 

«CN-Contact-R» protocol.

The  Detector  is  designed  for  operation  with  the  any  control

 

panel (hereinafter, «CP»

)  which  supports 

«CN-Contact-R»

  wireless 

 

two-way communication protocol.

1.2 The Detector is powered from a main lithium power supply battery 

СR123A type and СR2032 backup one.

1.3 Two temperature measuring and control channels:
Channel 1 – built-in signal processing unit (hereinafter, SPM);
Channel 2 – external temperature sensor (hereinafter, TS).
1.4  Two  operating  modes  are  available:  single-channel  mode 

and double-channel mode. External TS should be hooked up to the 

 

Detector if double-channel mode is chosen. Operational mode selection 
is available during the Detector logging in the the CP.

1.5 The Detector generates and provides transmission of the following 

messages:

- «Normal»

 – the temperature is within the preset range;

- «Channel 1 out-of-range» – temperature out of range in channel 

1 for 1°

 or more;

- «Channel 2 out-of-range» – temperature out of range in channel 

2 for 1°

 or more;

- «Tamper»

 – case or wall tampering;

- «Failure in channel 1»

 – SPM failure in channel 1;

- «Failure in channel 2»

 – TS failure in channel 2;

-  «

Main  power  supply  low-battery

»

  –  main  power  battery  supply 

voltage drop for 2.8

-0.4

 V and lower;

- «

Backup power supply low-battery

»

 – backup power supply battery 

voltage drop for 2.8

-0.4

 V and lower.

1.6 Two operating frequencies: main and reserve are used for the 

Detector – control panel wireless data exchange. The Detector switches 
to the reserve operating frequency automatically.

1.7 The Detector is designed for continuous and uninterrupted 

operation.

1.8 The Detector is able to operate in standalone mode (ref. section 

«

Standalone mode

»).

1.9 The preset limits of temperature range (the lower +17 °C, the upper 

+27 °C) rated by the manufacturer are stored in nonvolatile memory 
and may be changed by relevant control panel assisted command for 

each channel apart.

1.10 The detector provides immunity to electromagnetic interferences.
1.11 The level of industrial interference generated by the Detector 

does not exceed the norms established for the technical equipment 
operated  in  residential  buildings  or  connected  to  power  mains  of 

 

residential buildings.

2 Features

Table 1

Features

Value

Measurement error, not more:

within the temperature range from minus 10 up to +85 °С

within the temperature range from minus 55 up to minus 

11 °С and from +86 °С up to +125 °С

±1.0 °С

±2.0 °С

Operating temperature:

- the Detector

- external TS 

minus 20 ... +50 °С

minus 55 ... +125 °С

Permissible relative humidity at + 35 °С, max

95 %

IP rating:

- the Detector

- TS

IP30

IP65

Dimensions, max 

112 x 41 x 32 mm

TS cable group length, max 

10 m

Weight, max

0.1 kg

Battery life, not less

8 years

The operation duration under normal climate 

conditions and specified broadcast period than 30 

sec, not less:

- main power supply battery 

- backup power supply battery 

24 months

2 months

3 Scope of Delivery

Table 2

Name

Qty

Wireless temperature detector «CN-Celsius»

Screw 3-3х30.016
СR123A battery
СR2032 lithium battery
External temperature sensor

Wireless temperature detector «CN-Celsius» Installation Guide

1 pc.

2 pcs.

1 pc.
1 pc.

*

1 copy

* – available optionally

4 The Detector Construction

The  Detector  comprises  the  following  elements:  cover,  base  and 

printed circuit board (PCB).

The cover (not shown) is fastened to the base (1) by latches located 

on it’s end surfaces. For the cover opening push the latches by fingers.

At the front side of the PCB (2) the following entry is located: case 

tamper  (3),  two-color  LED  indicator  (4),  connecting  block  for  TS 
switching  (5),  main  power  supply  battery  holder  plate  (6), 

«

RESET

» 

contacts (8), SPM (9), sound alarm (10), antenna (11). Backup power 
supply battery holder plate and wall tamper are located on PCB back 
side. The PCB is fixed on the base by means of trip (7) and hooks on 
the opposite side of the base.

1

2

3

4

5

11

10

7

6

8 9

Figure 1 – The Detector with the opened cover

5 Sound and LED Indication

The Detector has the following indication modes:
- «Binding» procedure LED indication (procedure of logging in the CP);
- LED indication of the mode «Identification» is switched on by sending 

relevant command from CP and remains active during 15 min or until 

the case is opened;

- LED indication of the Detector state is switched on and remains 

unchanged for 15 min after the case is closed under conditions:

a) other LED indication types (except the sound alarm) absence; 
b) alarm «Tamper» message is not generated during this time period;
c) absence of command from the CP disabling the Detector state 

indication.

Indication modes are listed in the Table 3.
Table 3

The Detector Mode

Indication

Note

End of 

«Binding» 

procedure

LED lighting red for

2 – 3 sec

«Binding» mode

LED blinking green with 

0.25 sec period

The Detector logging in 

the CP in single-channel 

mode

LED blinking green with

 1 sec period

The Detector logging in 

the CP in double-channel 

mode

«Identification»

Alternate LED red and 

green blinking

on command from the 

CP

«Alarm in Channel 1» 

«Alarm in Channel 2»

 LED lighting red for 

4 sec *

State indication is on 

and «Identification» 

indication is off

Generation

«Alarm in Channel 1» 

«Alarm in Channel 2»

Sound alarm dual 

switching **

State sound indication 

is on

Fallback recovery

«Alarm in Channel 1»

«Alarm in Channel 2»

Single-shot sound alarm 

switching **

Radio communication 

quality appraisal

See sect. 

«

Radio communication quality appraisal

»

«Failure in channel 1»

«Failure in channel 2»

Orange LED indication 

dual switching with 

12 sec period *

State indication is on 

and «Identification» 

indication is off

«Normal»

Indication is off

*) – LED indication of the Detector state 

**) – Sound indication of the Detector state

+3.3V-  2 Channel 1

RESET