False ceiling-mounted motion detector
C-LOGIC 650-MD
SKU: CLOGIC650MD230VCBINT
INSTRUCTIONS MANUAL
ENGLISH
EN
The sensor is an active motion detector, it emits high-frequency electro-magnetic wave
(5.8GHz) and receives their echo. The sensor detects the change in echo from even the
slightest movement in its detection zone. A microprocessor then triggers the “switch light
ON” command. Detection is possible through doors, panes of glass or thin walls.
SPECIFICATION:
• Power supply: 220-240VAC
• Power frequency: 50/60Hz
• Installation sit: Indoors, ceiling mounting
• HF system: 5.8GHz CW radar, ISM band
• Transmission power: <10mW
• Rated load:
- Incandescence: 1200W
- Fluorescence: 300W
- LED: 300W
• Detection angle: 360°
• Reach: 1-10m radius, adjustable
• Time setting: 8sec to 12min
• Light control: 2~2000LUX
• Power consumption: approx.0.9W
Important: persons or objects moving towards the sensor are detected best.
NOTE: the high-frequency output of this sensor is <10Mw- that is just one 100th of the
transmission power of a mobile phone or the output of a microwave oven.
Reach setting (sensitivity)
Reach is the term used to describe the radii of the more or less circular detection zone pro-
duced on the ground after mounting the sensorlight at a height of 2.5m, turn the reach con-
trol fully anticlockwise to select minimum reach (approx.1m radii), and fully clockwise to se-
lect maximum reach (approx. 10m radius).
NOTE: the above detection distance is gained in the case of a person who is between
1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s
stature, figure and moving speed change, the detection distance will also change.
Time setting
The light can be set to stay ON for any period of time between approx. 8sec(turn fully anti-
clockwise) and a maximum of 12min(turn fully clockwise). Any movement detected before
this time elapse will re-start the timer. It is recommended to select the shortest time for ad-
justing the detection zone and for performing the walk test.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detect-
ing movement again. The light will only switch on in response to movement once this pe-
riod has elapsed.
Light-control setting
The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully
anti-clockwise to select dusk- to-dawn operation at about 2 lux. Turn it fully clockwise to se-
lect daylight operation at about 2000lux. The knob must be turned fully clockwise when ad-
justing the detection zone and performing the walk test in daylight.
TROUBLESHOOTING
Malfunction
Cause
Remedy
The load will not
work
Wrong light-control setting selected
Adjust setting
Load faulty
Change load
Mains switch OFF
Switch ON
The load work
always
Continuous movement in the detection zone
Check zone setting
The load work
without any
identifiable
movement
The sensor not mounted for detecting
movement reliably
Securely mount enclosure
Movement occurred, but not identified by the
sensor (movement behind wall, movement of a
small object in immediate lamp vicinity etc.)
Check zone setting
The load will not
work despite
movement
Rapid movements are being suppressed to
minimize malfunctioning or the detection zone
you have set is too small
Check zone setting
COVERAGE ADJUSTMENT
1-10m radii
TIME SETTING
8sec~12min
LUX ADJUSTMENT
2~2000LUX
CONNECTION-WIRE DIAGRAM
N
L'
L
Connect N, L with power; Connect N, L’ with load.
INSTALLATION
Place the detector above the false ceiling, with the flat side resting on the false ceiling.
MANUFACTURER:
MGL International
APAC:
MGL GLOBAL SOLUTIONS LTD
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA:
MGL EUMAN S.L.
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
AMERICAS:
MGL AMERICA, LLC.
US East Coast:
2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast:
760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com