Pen-type digital multimeter
C-LOGIC 3200
SKU: CLOGIC3200CBINT
INSTRUCTIONS MANUAL
ENGLISH
EN
The meter is a professional, portable multimeter with an easy to read LCD screen. Easy to
use with one hand, overload protection provided, low battery indication and suitable for use
in factories, schools, by enthusiasts and hobbyists alike.
The functions included are the measuring of AC/DC voltage, AC/DC current, resistance,
continuity, diode and logic test.
SAFETY INFORMATION
Warning
To reduce the risk of fire, electrical shock, product damage or personal injury, please
follow the safety instructions described in the user manual.
Read the user’s manual before using the meter. If the equipment is used in a manner not
specified by the manufacturer, the protection provided by the equipment may be impaired.
This meter is designed and manufactured according to safety requirements of EN61010-
1, EN61010-2-030, EN61010-2-033, EN61010-031 concerning electronic measuring
instruments with a measurement CAT III 600V and pollution degree 2 and safety requirements
for electrical measurement and test. Follow all safety instructions to ensure safe use of the
instrument. Following these guidelines will yield many years of satisfactory service.
PREPARATION
• When using the meter, follow the following safety rules:
1. Always take precaution to prevent electrical shock
2. Never misuse the instrument
• Check to see if the meter or any components were damaged during shipment.
• Check test leads for cracks or breaks in the insulation on the wires.
• If the test leads need to be re placed, meter’s safety can only be guaranteed with similar
spec leads.
DURING USE
• Always make sure the rotary switch is at the correct function and range.
• Do not exceed the protection limit values indicated for each function.
• Do not touch test lead tips while connected to a measurement circuit.
•
In manual range if the value to be measured is unknown, select the highest range first and
lower as needed.
• Do not measure voltages that may exceed 600V between the terminals and ground.
•
Always be careful when working with voltages above 60V DC or 30V AC RMS. Keep fingers
behind the probe barriers while measuring.
• Never connect the meter leads a cross a voltage source while the rotary switch is in the
resistance, diode or continuity mode. Doing so can damage the meter.
• Do not perform resistance, diode and continuity measurements on powered circuits.
• Disconnect the test leads from the circuit before changing functions on the rotary switch.
• Do not place the meter in an environment with high pressure/temperature, dust, explosive
gas or vapor.
• Stop using the meter if any abnormalities or failures occur.
• Do not connect the test leads to a circuit without the battery securely fastened.
• Do not store the meter in an area of direct sunlight, high temperature or high humidity.
MAINTENANCE
• Repairs should only be implemented by trained personnel.
• Remove test leads from measurement circuits before opening the battery cover.
• In order to avoid incorrect readings that may cause damage or personal injury, replace
batteries as soon as the
symbol appears.
• Use a damp cloth and mild detergent to clean the meter. Do not use abrasives or solvents.
• Move the rotary switch to the OFF position when the meter is not in use.
• Remove the batteries if the meter is not going to be used for an extended period of time.
Warning
To avoid electrical shock, damage or personal injury, remove test leads before opening
battery cover.
REPLACING THE BATTERIES
• When the
symbol appears, it indicates the batteries need to be replaced.
• Unscrew the battery cover and remove it from the meter.
• Replace the used batteries with new AAA batteries.
• Replace the battery cover and secure it to the meter.
Warning
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or
rechargeable (ni-cad, ni-mh, etc) batteries.
REPLACING THE TEST LEAD (OR ALLIGATOR CLIP)
lf the test lead’s insulation is damaged or has any wires exposed, the leads need to be re-
placed.
Warning
Use meet EN61010-031 standard, rated CAT.III 600V, or better test leads.
ACCESORIES
• Test leads
1 pc
• Alligator clip 600V 10A
2 pcs
• Short manual
1 pc
• Battery 1.5V AAA
2 pcs
MANUFACTURER:
MGL International
APAC:
MGL GLOBAL SOLUTIONS LTD
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA:
MGL EUMAN S.L.
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
AMERICAS:
MGL AMERICA, LLC.
US East Coast:
2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast:
760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com