background image

R

Page 4

TG115A

Section A: Description and Operation (cont.)

Regulator Status LED

Figure 5: Regulator Status LED Location

Table 2: Regulator LED Indications

LED COLOR

ALTERNATOR / REGULATOR STATUS

REQUIRED ACTION

GREEN  

(Solid)

Alternator and regulator operating normally.

No action required.

AMBER 

(Solid)

Voltage is below 25.0 V

If voltage is at or below regulator setpoint, allow charging sys-

tem to operate for several minutes to normalize operating tem-

perature. If charge voltage does not increase within 10 min-

utes, see Basic Troubleshooting procedures on page 5.

AMBER

(Flashing)

No alternator rotation detected.

Power down and restart alternator. If LED remains flashing 

amber, perform troubleshooting procedures in Chart 1 on page 

6.

RED 

(Flashing)

High voltage/OVCO condition detected.

Power down and restart alternator. If LED remains flashing red, 

refer to OVCO troubleshooting procedure on page 5.

NOTE:

 LED off = No power/output.

Содержание C528

Страница 1: ...ale or identify the meter burden by touching meter leads together Meter burden must be subtracted from final reading obtained Be sure the meter leads touch source area only Prevent short circuit damag...

Страница 2: ...s alternator shaft rotation Regulator can also be ener gized if an ignition energize signal is supplied by the vehicle to regulator IGN pin usually via oil pressure switch or multi plex system see pag...

Страница 3: ...voltage cut out OVCO Regulator shuts off field switching circuit if it senses 32 volts or higher for 3 seconds or longer Remote negative temperature compensation optional When used with compatible CEN...

Страница 4: ...point allow charging sys tem to operate for several minutes to normalize operating tem perature If charge voltage does not increase within 10 min utes see Basic Troubleshooting procedures on page 5 AM...

Страница 5: ...eplace batteries Electrical sys tem cannot be properly tested unless batteries are charged 95 or higher See page 1 for details 5 Connect meters to alternator Connect DMM red lead to alternator B termi...

Страница 6: ...battery voltage exist at both locations Yes No WITH ENGINE RUNNING Test for battery voltage from alternator B terminal to alternator B terminal Does battery voltage exist No Yes Alternator is faulty...

Страница 7: ...g CEN A10 114 test tool into alternator only Otherwise carefully test directly through alternator harness pins See Figures 6 and 7 below for reference 1 Set DMM to ohms test 2 Connect DMM red lead to...

Отзывы: