C-Data HF300-3815C-22D Скачать руководство пользователя страница 5

User

’s manual

 

 

 

  

input and output optical port of EDFA, please cover dust-proof cap to prevent the 

input and output end from being contaminated. 

 

2.

 

Production structure description   

2.1

 

Equipment dimension     

Adopting  the  19"  standard  1U  chassis:  485mm  (length)  X298.13mm  (width) 

X44mm (height). As shown in the following figure:       

 

2.2 The front panel diagram 

 

                         

 

OPT OUT

 

OPT IN    RS232        LED    PWR      NEXT    ON/OFF

 

 

 

                                                                     

2.3 The rear panel diagram 

 

 

ETH 

ALARM    ENTER 

Содержание HF300-3815C-22D

Страница 1: ...User s manual 1550nm Erbium Doped Fiber Amplifier HF300 3815C 22D User s Manual...

Страница 2: ...User s manual...

Страница 3: ...n 2 2 1 Equipment dimension 2 2 2 The front panel diagram 2 2 3 The rear panel diagram 2 3 Operation instructions 3 3 1 Connection 3 3 2 Turn on off procedure 3 3 3 LED indicator description 3 3 4 But...

Страница 4: ...before using device please make sure that the connector of the input and output tail fiber is kept clean especially if the output fiber connector has dirty goods it is easy to burn out output tail fib...

Страница 5: ...t end from being contaminated 2 Production structure description 2 1 Equipment dimension Adopting the 19 standard 1U chassis 485mm length X298 13mm width X44mm height As shown in the following figure...

Страница 6: ...line of rear panel turning on power switch at this time the LCD screen is on and LED indicator displays green After a moment turn on key switch Preheating 5 10 minutes and EDFA enters the normal worki...

Страница 7: ...nter next level sub menu when finishing modifying please press this button to confirm change 3 5 Display menu description Display device manufacturer and model on power The backlight of the LED screen...

Страница 8: ...U T P W R N O O U T P U T If output optical power is normal press ENTER button then enter output optical power setting interface as shown below S E T U P O U T P U T P W R 2 2 0 0 d B m Press NEXT bu...

Страница 9: ...A R M L I S T N o n e when appearing alarm information the display priority is displayed in the following order from high to low 1 laser key off 2 input optical power alarm mainly included into HIHI...

Страница 10: ...when only right power working normal displaying PWR2 and two powers all working normal displaying BOTH The power near the side shell is PWR2 P W R S T A T U S P W R 1 Press NEXT button jump to display...

Страница 11: ...shown below I P A D D R 1 9 2 1 6 8 0 0 1 1 0 0 Press NEXT button jump to display Press ENTER button enter IP address setting interface Current modified bit will flash S E T U P I P A D D R 1 9 2 1 6...

Страница 12: ...bit then pressing ENTER button thus returning subnet mask interface 17 Display gateway address interface as shown below G A T E W A Y A D D R 1 9 2 1 6 8 0 0 1 0 0 1 Press NEXT button jump to display...

Страница 13: ...C E S S 4 Alarm breakdown analysis Alarm Possible cause Pre warranty check Pin input optical power threshold no input optical power alarm 1 Optical transmitter no optical output 2 Input optical fiber...

Страница 14: ...good 3 Whether the ventilation holes are blocked on both sides of the chassis 4 Whether the EDFA is placed between the equipment with the heat source up and down and the distance of the equipment is...

Отзывы: