5.2 National Standard Class 2 Transponder
HF200-3613 series indoor 1310 optical transmitter can optionally configure
with national standard class 2 transponder (refers to NE2 in the following).
With webmaster that meets national standard, remote control for devices can
be achieved. Moreover, management content in webmaster is more than the
content in LCD menu.
Factory default IP address of NE2 is: 192.168.0.1. User need to change it to
meet user local network. Two ways to change IP, Telnet and Console, the
former is convenient to use, but if the IP address is lost, then the latter must be
used. Details on this part please refer to the content in the below.
After setting the correct IP address, then devices can connect to webmaster,
easy and convenient.
Without NE2, device can connect to PC through RS232 port or RS485 port
(this function will be disabled with NE2 configured). One PC can connect to