The following sections cover the single person and two person balancing procedures.
Single Person Return Balancing Procedure
Single person return balancing requires the use of more sophisticated equipment compared to the two
person return balancing method. Figure 4.3 shows the typical single person configuration of the test
equipment used in the single person return balancing procedure.
For single person return balancing, proper balancing of each unit depends on all preceding units being
balanced properly. It is particularly critical that the first amplifier or node be balanced correctly. If
balanced incorrectly, all succeeding units will also be affected. For this reason, when initially balancing,
start at the unit closest to the headend and work outward.
Because these are sweep systems, ingress may affect the outcome. Terminating return ports or keeping
all amplifiers terminated until activation will limit ingress. Standard sweep equipment also has a
“noise/ingress” feature that can be used for troubleshooting. This displays the noise seen in the
headend.
Tech Note TD0079 provides the generalized procedure using Wavetek Stealth
®
equipment (3ST/3HRV
and 3SRV), Hewlett-Packard CaLan equipment (3010H and 3010R), and the method using relatively
inexpensive video equipment (spectrum analyzer, signal generator, video camera, video signal
modulator, and TV monitor). For specific instructions on operation of the equipment, refer to the
manufacturer’s user manual.
Figure 4.3
Basic Operation of
Single Person Return
Balancing Equipment
Note
: If a unit closer to the headend is balanced incorrectly, all succeeding units will not
be balanced correctly using the single person method.
❷
A device (usually rack
mounted) at the headend
analyzes the incoming signal
and transmits the results back
to the hand-held unit.
❸
The hand-held unit receives
the data from the headend unit
and displays a trace of the
signal as it would appear at the
headend.
❶
A hand-held sweep
device transmits a signal to
the headend through the
return path of the amplifier
being balanced.
Headend
Line Extender
Содержание FlexNet E629
Страница 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...
Страница 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1 ...
Страница 23: ...Rev F Physical Identification 2 7 2 Figure 2 6 E629 Line Extender 19 4 5 3 21 17 20 14 13 13 16 ...
Страница 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2 ...
Страница 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4 ...
Страница 82: ...A 6 FlexNet 700 Series Line Extender Rev F A ...
Страница 88: ...B 6 FlexNet 700 Series Line Extender Rev F B ...
Страница 102: ...C 14 FlexNet 700 Series Line Extender Rev F C ...
Страница 104: ...D 2 FlexNet 700 Series Line Extender Rev F D ...
Страница 110: ...Index 4 Rev F ...
Страница 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...