background image

 

 

 

4.0 USER OPTIONS 

4.1 CHANGING ZONES ON CHIME 

"CHIME" is a facility to make particular zones chime when triggered. For 

example, you could have a front door chime when opened or a room with 

valuables in chime when entered. Chime is only active when the panel is 

UNSET. To configure any zones to chime you must first have chime enabled 

in the extended options (this needs to be set up by the installer on 

installation). If it is enabled press the * key. 

The display will show any zones currently set to chime. Press the key number 

of the zone you wish to enable/disable. If the control panel does not have the 

chime option programmed an error tone will be given. Press the * key to 

finish. 

4.2 AUTO TEST 

( Should be performed at least once a month ) 

Enter your four digit user code, the buzzer will emit a steady sound and the 

exit time will start. Press the * key followed by the 9 key. The exit buzzer will 

stop and all the LEDs will light. After the 10 seconds all the LED's will 

extinguish and the panel will then test the internal sounder, bell and strobe. 

Each will operate for 5 seconds then the control panel will then emit an accept 

tone and revert to the 'DAY' mode. You may end the test at any time by 

pressing the "*" key. 

4.3 CHANGING THE USER CODE 

There are two separate user codes available to the customer. A main 

MASTER code and a secondary user code which can be enabled or disabled 

by the user. By default the second user code will be disabled. 

1) Master user 2) Second user 

There are no differences to the usage of these codes. They both perform the 

same tasks and neither has an advantage over the other. The second code 

can be used for example when neighbours are looking after the premises and 

you don't want to give them your code, you can simply enable the second 

code for them and then when you return from your holiday disable that code 

again. This means they no longer have access via that code. 

To change a user code simply enter the four digit user code, the buzzer will 

emit a steady sound and the exit time will start. Press the * key followed by 

the 9 key, followed by the key of the user to be altered for example if you were 

changing user code 1 then you would press 1, the same applies for user code 

2. Once you have pressed a user key then the LEDs 1 2 3 and 4 will now 

come on to indicate a new 4 digit code is required. Enter your new code. As 

you press each key one LED will go out. 

 

 

 

This manual is from 

http://groups.msn.com/UKSecurityPanels 

 

 

 

Technical Manuals Online! - http://www.tech-man.com

Содержание Securit 700L

Страница 1: ...This manual is from http groups msn com UKSecurityPanels Technical Manuals Online http www tech man com ...

Страница 2: ... start Enter your user code to stop the sounder See section 3 3 to reset the control 1 2 PART GUARD Used when going to bed Start the exit procedure as for full set as above Then press the key followed by the 0 key The buzzer will change tone to a lower deeper sound and the LED s for any zones programmed to be isolated in part guard will flash The programmed part guard exit time will be selected an...

Страница 3: ...l be indicated by the internal AND external sounders going into alarm and also the strobe unit if fitted will begin to flash Enter your four digit user code to unset the system The LED display will indicate which zone caused the alarm See section 3 3 to reset the control panel 3 2 PERSONAL ATTACK ALARMS When a personal attack alarm is triggered it is usually triggered from a button You should go f...

Страница 4: ...DAY mode You may end the test at any time by pressing the key 4 3 CHANGING THE USER CODE There are two separate user codes available to the customer A main MASTER code and a secondary user code which can be enabled or disabled by the user By default the second user code will be disabled 1 Master user 2 Second user There are no differences to the usage of these codes They both perform the same task...

Страница 5: ... organised as SET and UNSET events All events are recorded The first alarm is shown by the relevant LED being lit continuously Subsequent alarms are shown by a fast pulse of the zone LED Any zones isolated are shown by a slow pulse of the zone LED The buzzer will sound whilst viewing the SET logs but will be silent whilst viewing the UNSET logs Pressing the 0 key while reviewing the logs will show...

Страница 6: ... sounder will stop and the zone LED will go out The buzzer will emit a low level steady tone as before Report any faults to your alarm installation company Press the key to finish The following is given so a record of your zone configurations can be made simply fill in where each zone is located in your premises THE FOLLOWING IS PROVIDED TO GIVE QUICK ACCESS TO VARIOUS PEOPLE IF A PROBLEM OCCURS T...