21
Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure
reliable RS232 control.
8.3 RS232 Communication Commands
Case-sensitive.
“[“, “]” in the commands are for easy recognition only and not necessary in real
operations. Other symbols including
“.”, “,”, “/”, “%”, “;”, “^”. are parts of the
commands.
Feedbacks listed in the column
“Feedback Example” are only for reference,
feedbacks may vary according to different operations.
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
8.3.1 System Commands
Command
Function
Feedback Example
PowerON.
Power on
Power ON!
Front Panel Unlock!
PowerOFF.
Power off
Power OFF!
/*Name.
Query the name of matrix
BG-UHD-88M18G
/*Type.
Query the model of matrix
PTN
/^Version.
Query the version of firmware
V1.0.0
CPLD:V1.0.0
RST.
Reset to factory default.
Factory Default!
8.3.2 Control Management
Command
Function
Feedback Example
DS[xx]ON.
Able output devices down-scaling
function.
[xx]=00~04,
xx=01~04 is the corresponding
number of output 5,6,7 or 8 port, if the
xx=00, it means all output 5~8 ports.
HDMI OUT 05 Down Scale
ON!
HDMI OUT 06 Down Scale
ON!
HDMI OUT 07 Down Scale
ON!
HDMI OUT 08 Down Scale
ON!
Содержание BG-UHD-44M18G
Страница 22: ...17 7 6 Interface Tab Modify the title bar label Modify the button labels...
Страница 39: ...34...