Baud Rate
】
For se
Baud Rate: 2400, 4800, 9600, 19200, 38400
【
PROTOCOL
】
PROTOCOL: VISCA, Pelco-D, Pelco-P
ETHERNET SETTING
Move Cursor to
【
Network Se
】
, then Joys
towards right to enter.
【
CHANNEL
】
To select the corresponding Channel
『
CAM1
』
~
『
CAM7
』
【
IP Address
】
Se
corresponding channel of Cam IP Address. It can
by
Digital Bu ons. When the number input to 3 bits, the cursor will Auto enter
next item. When the input number less 3 bits, Press
『
RESET
』
to confirm
and enter next items. If you input the wrong number, press
『
PRESET
』
to backspace.
【
PORT
】
Se
ca
RT OF Corresponding Channel Camera.
Passwords Setting
Moving Cursor to
【
Password Se
】
, then Joys
towards right to enter.
【
Password Enable
】
Se
ether to use the Passwor
Default password: 8888
Default password: 8888
【
Modify Password
】
Allows to change the password.
1.
Channel1
:
CAM1
2.
Cam IP
:
192.168.1.160
3.
Port
:
8090
1.
Password Enable
:
Disable / Enable
2.
Modify Password
Select the channel key you’d like to use (e.g., CAM1). Set the ID to Others,
then exit the menu. Select the corresponding numbers for the address you’d
like to set (e.g., 12), then press the channel key.
Example using CAM1:
Press CAM1, then set address to Others. Exit the menu, then press [1] + [2] +
[CAM1]. The address for CAM1 will now be “12.”