background image

 

 

BZ PRODUCTS, INC. 

 

INSTALLATION MANUAL 

VERSION 1.0  

 

MODEL  BZ 7/12  
                BZ 7/24   
                BZ 7/36  
                BZ 7/48 

 

 

PWM SOLAR CHARGE CONTROL

 

 

 

CAUTION! READ ALL INSTRUCTIONS PRIOR TO  

INSTALLING OR USING THIS EQUIPMENT. 

 

SAFETY INSTRUCTIONS: 

 

            Refer service to qualified service personal. Incorrect installation may result in risk 

of fire. Remove all sources of electrical power, photovoltaic and battery before servicing  

this equipment. Never charge a frozen battery. Warning batteries produce explosive 

gasses during normal operation. Install batteries in a well ventilated location. Follow 

battery manufactures maintenance and operational recommendations. Install properly 

rated fuses. 

 

MISWIRING THE BZ 7 WILL DAMAGE THE CONTROLLER AND VOID THE WARRANTY 

 

DESCRIPTION:

 The BZ 7 PWM charge controller is a high efficiency,  shunt type charge controller 

capable of charge currents of  7 amps. Features include a low loss Schotkey diode to prevent night time 
battery discharge,  easily adjusted float voltage, MOV lightning protection, battery voltage temperature 
compensation, float LED, easy installation, epoxy potted and five year limited warranty.  Made in USA 

 

SYSTEM LAYOUT: 

Plan your installation. Install the BZ 7 near the battery bank. Avoid installing the 

controller in wet, damp or confined locations. Do not install the BZ 7 in direct sunlight. Use short direct 
wiring to the controller, batteries and PV panels. Install the controller in accordance with all state, local and 
national electrical codes. Securely fasten the controller to a wall or other suitable structure. Provide support 
for all wiring. Provide proper ventilation for the batteries. 

 

WIRE AND WIRING:

  Use high quality stranded wire in all installations. Solid wire is not 

recommended. Use #10 or #12 wire to wire the PV panels and batteries. Protect wire from damage. 

 

Carefully plan the installation. Clearly labeling all wiring will simplify installation and help prevent wiring 
errors. Permanent wire markers are recommended for labeling all wiring. Rout wiring as directly as 
possible to the PV panels and battery. Take care to follow the wiring diagram exactly. Properly seal all 
wiring against water leaks. Provide proper ventilation for the batteries.  

 

CAUTION DISCONNECT ALL SOURCES OF ELECTRICAL POWER BEFORE CHANGING FUSES

 

FUSES:

  Install a 10 amp fuse and fuse holder in the B wire within 9” of the B terminal. 

Install a 10 amp fuse and fuse holder in the PV + wire. See wiring diagram for details. Warranty is void if 
no fuses are installed. 
 
 