9
14
Scissors
15
Tape
16
Other auxiliary tools that might
be used (for example:
Insulating gloves, insulating
shoes, insulating tape, etc.)
All installation
process
1.7 Specification
Parameters
MINIES-P30B3-AU-R2
On-grid Parameters
Nominal Voltage
240V AC/1Phase
Maximum Discharge Current
13A
Nominal Frequency
50HZ
Maximum Power
3KVA
Total Harmonic Distortion
<5%
Island detection
Auto Test, AFD
Max. grid port short-circuit fault current
980us,390A peak, 92.28Ar.m.s
Max. inrush current
0A
Off-grid Parameters
Nominal Voltage
230V AC/1Phase
Nominal Current
8.6A
Maximum Discharge Current
16A (5s protection)
Nominal Power
2KVA
Nominal Frequency
50Hz
Max.output short current
1.17ms,400A peak, 93.53Ar.m.s
Off-grid Protection
2KVA-2.2KVA overload:15min protection;
2.2KVA-3KVA overload: 1min protection;
3KVA-4KVA overload:5s protection;
Battery Parameters
Nominal Voltage(Range)
51.2V (44.8VDC-57.6VDC)
Battery Type
Lithium iron phosphate battery (LiFePO4)
Battery Usable Capacity
>3KWh
Max discharge current power
3.7KW
Max discharge current
65A
Max charge current power
3.7KW
Max charge current
65A
Other Parameters
Topology
Isolated
Wet location
No
Protective class
Class I
Pollution grade
II
Product Size
680mm (W)×256mm (D)×610mm (H)