background image

BYD Battery-Box Pro User Manual 

 

Parameter setting of charging current in various temperatures 

Operating temp. (℃) 

Normal current(Ad.c) 

-10~2 

15*N 

2~12 

42.5*N 

12~50 

175*N 

Remark: 
1. Effective time is 2mins when changing from one temperature range to another. 
2. N= battery quantity 
 
 

Parameter setting of discharging current in various temperatures 

Operating temp. (℃) 

Normal current(Ad.c) 

-10~50 

125~250*N 

Remark: N= battery quantity 

 

4 Technical Terms 

No. 

Term 

Comment 

Discharge 

Battery output power for load 

Charge 

To put electricity into battery by charger 

Full    charged 

Battery had been full charged, SOC is 100%. 

Idle 

Battery  is  on  status  of  neither  charge  nor  discharge  and  has  not  been  fully 
charged. 

Shutdown mode 

Power off 

SOC 

State of Charge 

SW 

Software 

HW 

Hardware 

Battery voltage 

The voltage between B+/B- 

10 

Pack voltage 

The voltage between P+/P- 

11 

Cell voltage 

Single cell voltage 

12 

Failure 

Battery or BMS are broken, and unit needs to be replaced 

13 

Alarm 

Battery will stop charging or discharging immediately 

14 

Protect 

Battery  stops  charging  or  discharging  (e.g.  cell  is  overvoltage).  Operation  can 
resume at a later stage. 

15 

Over discharged 

Battery module or batteries overvoltage, need to be recharged timely 

 

 

Содержание Battery-Box Pro series

Страница 1: ...BYD Battery Box Pro User Manual Battery Box Pro 13 8 Version 6 0...

Страница 2: ...of BMU 7 5 4 General introduction of Battery Box 13 8 module 8 5 5 General introduction of BMS 8 5 6 Operating environment 8 6 Cleaning and Maintenance 9 6 1 Cleaning 9 6 2 Maintenance 9 6 2 1 Rechar...

Страница 3: ...ormal failure and actions Alterations to the product e g changes or modifications are only permitted with the express written permission of BYD Unauthorized alterations will void warranty claims BYD s...

Страница 4: ...rminals to touch conductive objects such as wires Do not dispose of batteries in a fire which may explode Operation Do not touch the battery pack with wet hands Do not crush drop or puncture the batte...

Страница 5: ...Battery module 1 kWh 13 8 Usable Energy 1 kWh 13 8 Max Output Power kW 12 8 Peak Output Power kW 13 3 60s Round Trip Efficiency 95 3 Under test condition 1 Nominal Voltage Vd c 51 2 Operating Voltage...

Страница 6: ...electricity into battery by charger 3 Full charged Battery had been full charged SOC is 100 4 Idle Battery is on status of neither charge nor discharge and has not been fully charged 5 Shutdown mode P...

Страница 7: ...ox energy storage system combined with high performance BYD lithium battery consists of cabinet battery BMS and BMU Each set of the storage system includes 2 battery modules connected in series and up...

Страница 8: ...U Battery management unit Provides communication with external equipment 4 BMS BMS Battery module management unit and communicate with BMU 5 3 General introduction of BMU BMU is the battery management...

Страница 9: ...ent to make sure that the system run normally Display and communication interface No Interface Mark Function SOC LED SOC Indicate current SOC of battery RUN LED RUN Indicate that the Battery is in run...

Страница 10: ...stored in position with the temperature range of 20 45 and maintained regularly according to the following table with 0 5C 125A current for 1 hour after a long time of storage Recharge conditions whe...

Страница 11: ...es One or some batteries are disconnected 1 Check RS485 cable and battery address 2 If the connection and the address are correct please contact the after service provider Flash 4 times Any battery fa...

Страница 12: ...ider 10times PACK over voltage protection Contact the after service provider Alarm status indicated by flashing red led Fault phenomenon Times Possible cause Solution 1 Red led Err is always on 2 Pres...

Страница 13: ...to Appendix 2 in this user manual 8 4 Emergency Please cut off the power supply and turn off the battery in emergency 9 Warranty BYD provides warranty when the product is installed and used according...

Страница 14: ......

Страница 15: ...Ltd Address 14 47 51 Lorraine St Peakhurst NSW 2114 Customer Service Mailbox service alpspower com au Telephone 61 2 8005 6688 Website www alpspower com au Europe EFT Systems GmbH Address Buchenstr 3...