Page 14
①
B+
B+
Connects battery
’s positive cable to power the BMS
②
B-
B-
Positive terminal of BMS
③
P-
P-
Negative terminal of BMS
④
SOC LED
SOC
Indicates state of charge of battery
⑤
RUN LED
RUN
Indicates the Plus system is running
⑥
ERR LED
ERR ADDR
Indicates error status
⑦
Alarm LED
Alarm
Indicates alarm status
⑧
RJ45 terminal
RS232/RS485
Communication ports
⑨
Address
ADDR
When parallel connection, address needs setting
⑩
Reset
RESET
Battery activity when no external power/add on battery.
5.6 Operating environment
Operating environment parameters
No.
Item
Requirement
Unit
Remark
Min.
Typical
Max.
1
Discharging
temperature
-20
25
55
℃
2
Charging temperature
-10
25
50
℃
3
Relative humidity
5
95
%
non-condensing
4
Absolute humidity
0.26
25
g/m3
5
Elevation
-
2000
-
m
6
IP level
20
5.7 BMS address switch introduction
After finishing the battery installation, installers should setup the battery address through the
“ADDR” switch.
“ADDR” switch introduction:
Function
: Communication between battery and BMU. The BMU will communicate with external
equipment when using CAN communication.
DIP switch definition:
There are 6 bit switches, keeping the switch down it means ”0”, turn up the switch to “ON” means
“1”.