background image

1

PRODUCT REGISTRATION

SAFETY

INTRODUCTION

WHAT’S IN THE BOX

PRODUCT OVERVIEW

This bXterra product is constructed to provide unmatched power pro-

tection, quality and performance for the duration of its lifetime. Please 

take a few minutes to register your new product at www.bxterra.com/

registration. Registration certifies your product’s warranty, confirms 

your ownership in the event of a product loss or theft and entitles you 

to free technical support. Please register your product now to receive 

the benefits of bXterra ownership.

SAVE THESE INSTRUCTIONS: 

This manual contains important 

instructions that should be followed during installation and 

maintenance of the EBM.

• WARNING!

 The mounting shelves are not intended to support 

more than one EBM. Do not stack multiple battery packs on a 

single set of mounting shelves. Failure to follow this warning may 

lead to product damage and the risk of physical injury.

• This unit is intended for installation in a controlled environment 

(a temperature-controlled and indoor area free of conductive 

contaminants). Please avoid installing the UPS and EBM in 

locations where there is standing or running water, dust, direct 

sunlight or excessive humidity. 

• Use caution when lifting battery packs. Because of the 

considerable weight of all battery packs, at least two people 

should assist in lifting and installing them.

• Be sure that the battery packs and UPS system use the same DC 

voltage before connecting them.

• Use of this EBM in life-support equipment or situations is not 

recommended. bXterra does not sell equipment meant for life-

support or medical applications.

• When connecting multiple EBMs to a single bXterra UPS, the 

battery packs should be approximately the same age.

• The suggested mounting procedures in this manual are for 

common rack types and may not be appropriate for all rack 

configurations. The user must determine the appropriate 

mounting hardware and procedures before mounting the EBM. 

• Do not unplug EBMs from the UPS while the UPS is on battery 

power, due to the possibility of dangerous arcing and shock.

• It is not unusual for sparks to occur when connecting external 

batteries. 

• 

As defined in the Protection of Information Technology Equipment 

ANSI/NFPA 75, this EBM is not for use in a computer room. (US 

installations only). Contact bXterra to order a special battery kit if 

needed to meet the ANSI/NFPA 75 requirement.

Servicing of batteries should be performed or supervised by 

personnel knowledgeable about batteries and the required 

precautions. When replacing batteries, replace with the same type 

and number of batteries or battery packs. 

CAUTION: 

The battery pack can energize hazardous live parts inside 

the UPS even when the AC input power to the UPS is disconnected.

CAUTION:

 Do not dispose of batteries in a fire. The batteries may 

explode. 

CAUTION:

 Do not open or mutilate batteries. Released electrolytes 

are harmful to the skin and eyes. It may be toxic. 

CAUTION:

 A battery can present a risk of electrical shock and high 

short-circuit current. Contact with any part of a grounded battery can 

result in electrical shock. 

The following precautions should be observed when working on 

batteries:

a) Remove watches, rings or other metal objects

b) Use tools with insulated handles

c) Wear rubber gloves and boots

d) Do not lay tools or metal parts on top of batteries

e) Disconnect charging source and load prior to installing or 

maintaining the battery

f) Remove battery grounds during installation and maintenance 

to reduce likelihood of shock. Remove the connection from 

ground if any part of the battery is determined to be grounded.  

CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN 

INCORRECT TYPE. 

Visit www.bxterra.com for information on the 

specific replacement battery type for your UPS or EBM. 

NOTE:

 This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This 

equipment generates uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in 

a installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

- Consult an experienced radio/TV technician for help.

WARNING: Changes or modifications not expressly approved by the 

party responsible for compliance could void the user’s authority to 

operate the equipment.

Remove the EBM from its package and inspect it for damage that may 

have occurred during shipping. If any damage is discovered, repack 

the unit and return it to the place of purchase. 

The following items are inside the box: 

1

Circuit Breaker

1

2

Battery Output

2

3

Battery Input

3

Thank you for choosing a bXterra Extended Battery Module (EBM). 

The bXterra BP24V-SP2U, BP48V-SP2U and BP72V-SP2U Extended 

Battery Modules, or battery packs, are designed for use with the 

bXterra SP series of Line-Interactive UPS systems equipped with 

external battery pack connectors. 

•  Extended Battery Module

•  User Manual

•  Battery Cable to Connect to 

UPS or Another EBM

•  Ear Racks x 2

•  Ear Rack Screws x 8

•  Tower Stand Extensions x 4

•  Extension Screws x 4