5. Charge Bar

Having set the display on the control panel, you will notice that during normal operation, 

there is a charge bar running along the bottom of the display. This charge bar shows the 

percentage of water softener capacity remaining since the last regeneration. Immediately 

following a regeneration, the charge bar returns to 100%.

6. Resetting the display during normal operation.

If the time is to be adjusted during normal operation, press any key to illuminate the 
display, press the     

keys will alter the time as described on page12.

 key once. The display will flash and indicate present time. Using the        

7. Power loss

The AMECS system will maintain the individual programming parameters of the water 

softener for up to 72 hours.

If the power cut lasts longer than 72 hours, the control will flash "0:00" when power is

returned to the control. The unit will continue to keep time from the moment power is 

restored. In this situation, the time of day will need to be reset.

P

RA

T

EE

R

HT

8. Flow indicator

During normal operation, a flow indicator will flash on the display at a rate of one litre per 

pulse when water is passing through the softener.

9. Cleaning

Your water softener may be cleaned using a damp cloth and a mild detergent. Do not use 

bleaches, solvents or spirits as they may damage the surfaces.

4. Setting the Type of Salt. (See Fig4) “For WS455 and WS555 models only 

To operate effectively, your water softener must be set to the type of salt that you intend to 

use in the system. Block salt (BS) and care cubes (CC) are suitable. Use the          

keys to select the type of salt used.

Pressing the      button will return the display to the Normal Operation mode. 

Programming is now complete and now further adjustments of the water softener is 

required. 

Remember to check the salt and water level in the brine cabinet weekly. 

 13

Set

00:00

Time

12

1. SETTING THE TIME OF DAY (see Fig1)
The first two digits (00) of the display will flash, prompting the installer to set the time.
The time is adjusted by using the              keys. Pressing the         key enters the hours. 
The minutes are set by using the              

 keys

Pressing the

 key once enters the minutes and moves the display into the Set 

Hardness mode.

Set

00:00

Time

2. SETTING THE WATER HARDNESS (see Fig2)
The display default is 300 (typical hardness level) which indicates a setting suitable for
hard water with a value of 300 parts per million of hardness minerals. Use the
keys to adjust the setting to match that of the one you obtained / identified earlier. See
page 11 for details.

Pressing the         set key once enters the hardness and moves the display to Set
Recharge Time Mode.

Hardness
Set

300

PROGRAMMING PROCEDURE

PAR

T

TWO

Set

02:00

RECHARGE Time

Fig1

Fig2

Fig3

3. SETTING THE RECHARGE TIME (see Fig3)

To operate effectively, your water softener needs to regenerate periodically (dependent

on the hardness of the supply and amount of water used). The default time of day when

this is to occur is 2.00am. To alter this setting, use the

keys.

Pressing the        key once enters the recharge time and returns the display to Normal 

Operation Mode and no further adjustment of the water softener is required.

WSINST 20pp A5 Seot 2017.indd   12

08/09/2017   08:43

Содержание WS Series

Страница 1: ...and operating instructions close at hand to avoid any mistakes and before carrying out any work on the device you should read the fitting and operating instructions carefully and follow them While our data sheets and brochures should provide advice to the best of our knowledge the content thereof is not legally binding BWT WS Range Water Softener WSINST 20pp A5 Seot 2017 indd 1 08 09 2017 08 43 ...

Страница 2: ...is manual Protect from high low temperatures Important do not install the water softener where it or its connections including the drain overflow lines will be subject to temperatures under 5ºC or above 40ºC Electrical safety Only use the transformer plug supplied Before use ensure that the connection data on the data plate voltage and frequency match that of the mains electricity supply If in any...

Страница 3: ...process 6 7 Installation and operating considerations 8 Typical Installation layout PART TWO 9 11 Installing your water softener Programming procedure 12 14 PART THREE Troubleshooting guide 15 16 Specification table 17 Warranty 18 CONTENTS 3 WSINST 20pp A5 Seot 2017 indd 3 08 09 2017 08 43 ...

Страница 4: ... based on the extensive experience of BWT in the UK Rotary valve means less moving parts for greater reliability Flow rates suitable for use on conventional and modern plumbing systems Custom backlit easy read display At a glance capacity remaining indicator helping to provide a continuous supply of softened water Memory back up facility allows the AMECS to restore all key settings held in its mem...

Страница 5: ...t To drain Brine pick up Rinse water to drain Hard water SOFTENING CYCLE REGENERATION CYLCE RINSING CYCLE Periodically these resin beads are automatically cleaned and regenerated by rinsing with a small amount of brine a salt solution The brine with the accumulated hardness is then flushed away to the drain All this takes place automatically All that remains for you to do is occasionally top up th...

Страница 6: ...rong enough to support an approximate total weight of 50 Kg Your new water softener has been designed to operate efficiently and effectively with an incoming water pressure of between 1 7 to 5 BAR If your water supply is likely to fall outside these limits then we would recommend that a booster pump or pressure limiting valve should be fitted respectively PLEASE NOTE UK Water Regulation guidelines...

Страница 7: ...the water softener above ground level e g In the loft the following instructions should be strictly adhered to 4 Plumbing systems 5 Backflow prevention device 5 Your water softener installation must include at least one drinking water tap that is not fed by the water softener It is recommended that individuals on a low sodium diet should follow the Department of Health s advice that water from a d...

Страница 8: ... Key to the diagram A Non return valve B Pressure reducing valve where required C Inlet valve D By pass valve E Outlet valve 6 PART ONE A B C E D Mains stop valve Drinking water Drain hose Overflow Valve Head Brine Cabinet Inlet Outlet Rising Main The overflow must discharge to a place that is visible outside the building TYPICAL INSTALLATION LAYOUT WSINST 20pp A5 Seot 2017 indd 8 08 09 2017 08 43...

Страница 9: ...can raise the drain to a maximum of 3 metres above the valve head P R A T O W T It is very important to establish the water pressure before installing the water softener If the water pressure is low then the water softener may not operate effectively If it is too high then components inside the unit may be damaged Water pressure should be tested with a gauge at the kitchen tap or outside tap It sh...

Страница 10: ...the socket with the switch in the OFF position 10 7 Blending control 6 Filling the brine cabinet salt usage and the salt alarm All machines are factory set to produce water that is soft If you prefer water which is less soft turn the blending knob on the left side of the valve anti clockwise until the water meets your requirements Notes on salt usage Your water softener will only perform effective...

Страница 11: ...time Shake the bottle in between and keep adding tablets to the water until the solution turns from wine red to blue record the number of tablets as you go Using the data table supplied with your kit match up the number of tablets with the hardness You will need this figure when programming your water softener in the next section of this manual supplied to the fill line with water from a hard wate...

Страница 12: ...he keys to adjust the setting to match that of the one you obtained identified earlier See page 11 for details Pressing the set key once enters the hardness and moves the display to Set Recharge Time Mode Hardness Set 300 PROGRAMMING PROCEDURE PART TWO Set 02 00 RECHARGE Time Fig1 Fig2 Fig3 3 SETTING THE RECHARGE TIME see Fig3 To operate effectively your water softener needs to regenerate periodic...

Страница 13: ...e control The unit will continue to keep time from the moment power is restored In this situation the time of day will need to be reset P R A T E E R H T 8 Flow indicator During normal operation a flow indicator will flash on the display at a rate of one litre per pulse when water is passing through the softener 9 Cleaning Your water softener may be cleaned using a damp cloth and a mild detergent ...

Страница 14: ...ffect your water softeners performance If however the number of guests staying with you increases you will notice that the water usage patterns will alter This may cause your water softener to regenerate more often than normal As the water usage returns to its normal level the number of regenerations will also return to normal Your water softener is controlled by a microprocessor which constantly ...

Страница 15: ...the pressure is between 1 7 5 0 bar 9 1 Pressure falls outside of the water softener specification Fit a pressure reducing valve or booster pump as required 9 1 Is there flow through the drain line Check the drain line is not kinked blocked or frozen 9 3 Has there been a power interruption Check that the power is on and the connections are secure 10 5 15 PART THREE TROUBLESHOOTING GUIDE IF YOUR WA...

Страница 16: ...There should be no flow to drain in the service position Isolate the softener and call for service 11 9 PROBLEM EXCESSIVE SALT USAGE Check the hardness setting Reduce the hardness if incorrect 11 12 8 PROBLEM ELECTRONIC DISPLAY The display shows error code Err 1 audible alarm sounds see note below Check all the connections are secure Turn the power off for 10 seconds then turn back on allow the sy...

Страница 17: ...18 22 27 32 Unit weight Kg in service 50 40 50 61 66 Maximum peak flow rate L min hi flo 30 50 50 50 30 50 30 50 Maximum continuous flow rate L min hi flo 25 30 30 30 25 30 25 30 Basic flow rate flow 1 bar pressure loss 26 24 26 28 28 Minimum flow rate L min hi flo 10 10 10 10 10 10 10 10 10 10 Min Max salt usage per regeneration Kg 1 2 2 4 0 3 1 2 0 6 2 0 0 9 2 5 1 2 3 0 Waterused per regeneratio...

Страница 18: ...tion e g the failure to follow instructions or advice given by BWT or it s representatives Any defect caused by malicious or willful action negligence misuse or third party interference Any defect or damage occasioned by fire lightening explosion flood storm frost impact or other extraneous cause Consequential loss arising as a result of a defect occurring in the water softener or installation Any...

Страница 19: ...WSINST 20pp A5 Seot 2017 indd 19 08 09 2017 08 43 ...

Страница 20: ...enquiries bwt uk co uk BWT 2017 In the interest of product development we reserve the right the alter specifications without prior notice All photographs are to be used as a guide only Terms and conditions apply E OE WSINST 20pp A5 Seot 2017 indd 20 08 09 2017 08 43 ...

Отзывы: