Function 

2.1 

Ion exchange 

When the water passes the filter, calcium and 
magnesium ions is absorbed by the ion 
exchange mass while the corresponding 
amount of sodium ions is carried to the water. 
This procedure is called ion exchange (in this 
case softening). 

2.2 

Regeneration 

When the ion exchange mass is saturated 
with calcium and magnesium, it must be 
treated so it can soften the water again. This 
treatment is called regeneration. 

Regeneration begins by adding the diluted 
salt solution (brine) with regulated flow to 
achieve even distribution and sufficient 
contact time in the ion exchange mass. 

Calcium and magnesium are consequently 
released and rinsed to drain while the ion 
exchange mass is again saturated with 
sodium. 

Once the salt solution is introduced, the 
regeneration continues with the first rinse, 
which displaces the salt solution through the 
ion exchanger. 

The regeneration ends with a second flush 
that is controlled by the conductivity of the 
wastewater. 

After 2nd flush, the filter is automatically 
switched on for operation. 

Installation 

a.  Place the unit on a flat surface, with 

the salt container on the side. 

b.  Connect the top and bottom pipes to 

the tanks and the valve rack. 

c.  Fill both tanks half with water before 

filling them with ion exchange 
resin.(see chap. 4.1)  

d.  Connect the inlet to the raw water 

supply and the outlet for consumption 
– the flange connections is DN50 for 
HVD 400, 600, 900 and DN100 for 
HVD 1200/1550. Be aware, that the 
connected pipes shall be relieved. 

e.  Connect the waste water 

– flange size 

DN40 

f.  The dynamical pressure shall be at 

min. 3 bar and max 10 bar. 

g.  Connect the unit to power supply 230 

V AC. 

Commissioning 

Please note that during operation of the 
filters, ensure that no ion exchange is flushed 
out 

 
 
 
 
 
OPERATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
REGENERATION 

Na

+

 

Na

+

 

Na

+

 

Na

+

 

Na

+

 

Ca

2+

 

Ca

2+

 

Ca

2+ 

H

2

Mg

2+ 

Содержание Rondomat HVD 1200

Страница 1: ...Rondomat HVD 400 1550 Softening Unit Installation and operation manual EN 659997220 EN 4...

Страница 2: ...u 8 5 1 2 Functions in the menu 8 5 2 Operation 9 5 2 1 Information in operation 9 5 2 2 Functions in Operation 9 5 3 Mimic 10 5 3 1 Information in Mimic 10 5 4 Auto Man 10 5 4 1 Information in Auto M...

Страница 3: ...ounters 13 5 11 Language 14 5 11 1 Information in Language 14 5 11 2 Functions in Language 14 5 12 Time and date 14 5 12 1 Information in time date 14 5 12 2 Functions in time date 14 5 13 Password 15...

Страница 4: ...ly low salt and water consumption during operation due to the built in conductivity measurement The system is controlled by a PLC so it is always possible to change the operating parameters The PLC is...

Страница 5: ...t rinse which displaces the salt solution through the ion exchanger The regeneration ends with a second flush that is controlled by the conductivity of the wastewater After 2nd flush the filter is aut...

Страница 6: ...yed This valve is for filling the last part of the Strong cation and the inert resin Firstly the top pip have to be removed so the water can over float when the resin is filled into the container At t...

Страница 7: ...EN 7 c Fill the salt container with water by opening the valve for incoming water Let the valve stay open for operation Figure 2 Salt Container Keep undissolved salt out of the tube...

Страница 8: ...Press Alarm settings Press Reg settings On the operating screen it is possible to start and stop the operation and regeneration On the mimic screen is indicated status of operation and valve pump On t...

Страница 9: ...ed Reg Timer Regeneration time in the activated step 5 2 2 Functions in Operation Press OFF ON Press Start Reg Press Step Reg Changes to alarm history where all alarm occurrences are stamped with time...

Страница 10: ...mps Pumps Black OFF White ON Valves Black closed White open 5 4 Auto Man 5 4 1 Information in Auto Manuel This function visualize the manual interference AUT MAN 5 4 2 Functions in Auto Manuel Selecte...

Страница 11: ...pr m Select options 5 6 Alarm settings 5 6 1 Information in Alarm Settings Delay of various alarms and set points for the conductivity in the second flush 5 6 2 Functions in Alarm Settings Setting di...

Страница 12: ...the hardness of the raw water It s possible change between dH fH and ppm CaCO3 The capacity in the Ion exchange resin preconfigured to 2 8 m3 Password See chapter 5 13 5 8 Alarm 5 8 1 Information in A...

Страница 13: ...Functions in Alarm Log By pressing the START button can the UP DOWN buttons be used to go through the registered alarms CLEAR ALL Deletes the log Password Se afsnit5 13 5 10 Counters 5 10 1 Informatio...

Страница 14: ...options 5 11 2 Functions in Language To select a language Press the preferred language 5 12 Time and date 5 12 1 Information in time date Date and time 5 12 2 Functions in time date Date and time can...

Страница 15: ...We recommend to use salt tablets or granulated vacuum salt if using a Saturator The plant is designed for a brine solution of 300g liter of water Frequently empty and rinse the salt container The qua...

Страница 16: ...After a prolonged period of closure take the following precautions Drain the filter containers for liquid and perform a double regeneration on the ion exchanger BWT Denmark A S offers various types of...

Страница 17: ...r 10 Pipe connection DN 50 100 Water connection DN 40 Height A mm 2520 2600 2800 2750 2800 Width B mm 2800 3000 3120 3550 4000 Depth C mm 1400 1500 1600 1800 1900 Height Salt container D mm 1120 Diame...

Страница 18: ...EN 18 9 Spare part drawing...

Страница 19: ...6 1 Once a year 12 Pressure gauge for reduc valve 200781108 13 Dist syst T 14 36 flange top 350244100 1 14 Dist syst T 24 flange bottom 350244108 1 15 Salt hose 5 8 401528050 1 16 Drain elbow 40537873...

Страница 20: ...EN 20 11 P I Diagram...

Страница 21: ...45 43 600 900 BWT BWT dk www BWT dk Here by declares that HVD 400 600 900 1200 1550 is in conformity with the provisions of the Machinery Directive Directive 2006 42 EC is in conformity with the provi...

Страница 22: ...__________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _____...

Страница 23: ...__________________________________________________________ _______________________________________________________________________________________ _____________________________________________________...

Страница 24: ...EN 24 Bwt com...

Отзывы: