2021/03 - Indice de révision : B Code : 29740
TRAITEMENT DE L'EAU
47/88
Calibrating the pH sensor without a buffer solution:
The Chlorine generator allows you to carry out a quick calibration without using a buffer solution to correct
small deviations, without taking the sensor out of its housing, by comparing the value returned by the
sensor with that read by another measurement device (that has been recently calibrated).
Current measurement = value measured by the sensor
Target measurement = adjust this value using the Plus/ Minus keys until it matches the current measurement.
Once the Target Measurement has been adjusted, press OK, the sensor will align to this value.
Calibration of the Redox sensor using buffer solutions:
Use the 465 mV buffer solution delivered with the Redox kit and the "neutral" rinsing solution, and follow
the steps shown on screen.
Once the target value has been adjusted to 465 mV, press OK. The sensor will align to this value.
Calibration of the Redox sensor without using buffer solutions
The Chlorine generator allows you to carry out a quick calibration without using a buffer solution to correct
small deviations, without taking the sensor out of its housing, by comparing the value returned by the
sensor with that read by another measurement device (that has been recently calibrated).
Current measurement = value measured by the sensor
Target measurement = adjust this value using the Plus/ Minus keys until it matches the current measurement.
Once the Target Measurement has been adjusted, press OK, the sensor will align to this value.
Calibration of the temperature sensor
The temperature sensor is calibrated by adjusting the value indicated by the device to match that of a
thermometer confirmed to be exact and precise.
Current measurement = value measured by the sensor
Target measurement = adjust this value using the Plus/ Minus keys until it matches the current measurement.
Once the Target Measurement has been adjusted, press OK, the sensor will align to this value.
Содержание PRO A
Страница 56: ...2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 56 88...
Страница 86: ...Notes 2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 86 88...
Страница 87: ...Notes 2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 87 88...
Страница 88: ...2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 88 88...